Bloomfield Aquarius 8372EU Скачать руководство пользователя страница 3

TABLE OF CONTENTS 

SPECIFICATIONS 

Thank You for purchasing this 
Bloomfield Industries appliance. 
 
Proper installation, professional 
operation and consistent 
maintenance of this appliance will 
ensure that it gives you the very 
best  performance  and  a  long, 
economical service life.  
 
This manual contains the 
information needed to properly 
install this appliance, and to use, 
care for and maintain or repair the 
appliance in a manner which will 
ensure its optimum performance. 

WARRANTY STATEMENT                                  xi 
SPECIFICATIONS                                                  1 
FEATURES & OPERATING CONTROLS            2   
PRECAUTIONS & GENERAL INFORMATION    3 
AGENCY APPROVAL INFORMATION                3   
INSTALLATION                                                       4 
OPERATION                                                            5 
CLEANING INSTRUCTIONS                                8 
TROUBLESHOOTING SUGGESTIONS             10 
SERVICING INSTRUCTIONS                            11 
     Delime Water Tank                                         14 
EXPLODED VIEWS & PARTS LISTS                 16 
WIRING DIAGRAM                                              19 

  MODEL       STYLE                                 VOLTS     WATTS      AMPS           POWER SUPPLY  
                                                                                                          1ø                         CORD 

 
                      3 WARMER STEP-UP        220 - 240 
  8372EU       DECANTER BREWER          VAC        2100 W       10 A             CEE 7/7 Male Plug 
                      with FAUCET                      50/60 Hz 
 
 

Содержание Aquarius 8372EU

Страница 1: ...M681EU 040913 cps 681EU OWNERS MANUAL for BOTTLED WATER DECANTER COFFEE BREWERS MODEL 8372EU for 3 Gallon and 5 Gallon Plastic Bottles Includes Installation Operation Use Care Servicing Instructions M...

Страница 2: ...ninety 90 days from date of purchase on non warranted equipment Any use of non genuine Bloomfield parts completely voids any warranty 11 Installation labor and job check out are not considered warrant...

Страница 3: ...care for and maintain or repair the appliance in a manner which will ensure its optimum performance WARRANTY STATEMENT xi SPECIFICATIONS 1 FEATURES OPERATING CONTROLS 2 PRECAUTIONS GENERAL INFORMATION...

Страница 4: ...FEATURES AND OPERATING CONTROLS 2 Fig 1 Features Operating Controls...

Страница 5: ...liance use limitations and associated hazards Operating instructions and warnings must be read and understood by all operators and users Except as noted this piece of equipment is made in the USA and...

Страница 6: ...del 8372EU is equipped with a cord and plug It requires a 220 240 volt 10 amp circuit 50 Hz 2 wire plus ground with CEE 7 7 Receptacle IMPORTANT Supply power must match nameplate for voltage and phase...

Страница 7: ...equate amount of water in place will produce very little or no brewed coffee IMPORTANT When installing water bottle be careful to not overflow the basin pan DO NOT fill the basin pan prior to installi...

Страница 8: ...IC OPERATION Water is supplied to the hot water tank by a bottle inserted in the bottle ring Water will flow from the bottle into the basin pan until the water level reached the open mouth of the bott...

Страница 9: ...ng a brew may lower the temperature of the brew water PREPARATION Place one 1 genuine Bloomfield paper filter in the brew chamber Add a pre measured amount of fresh coffee grounds Gently shake the bre...

Страница 10: ...ed to clear clogged spray holes Rinse the spray disk with clean water and allow to air dry 7 Wash the brew chamber in a sink using warm water and a mild detergent A bristle brush may be used to clean...

Страница 11: ...brewer 7 Wash the basin pan and bottle ring with a clean cloth and mild detergent 7 Soak the basin pan basin seal and top panel in sanitizer per the directions supplied with the sanitizer 8 Rinse the...

Страница 12: ...SIBLE CAUSE Brewer unplugged or circuit breaker tripped Thermostat set too low Hi Limit thermostat tripped Damaged internal component or wiring Water bottle empty Too much coffee grounds Timer out of...

Страница 13: ...sed on altitude Upon completion reinstall top panel CAUTION Electric Shock Hazard Opening access panels or removing warmer plates on this brew may expose uninsulated electrical components Disconnect b...

Страница 14: ...er bottle Run water from the hot water faucet until no more water flows Remove top panel Siphon water from the tank through the faucet supply fitting until the water level in the tank is below the tan...

Страница 15: ...ove water bottle and top panel Cut tie straps from solenoid hose connections Remove wiring connections from solenoid coil Remove solenoid Reassemble in reverse order REPLACE TIMER ASSEMBLY Unplug powe...

Страница 16: ...Brush Large Sink or other appropriate work area 1 Disconnect brewer from the electrical supply Remove the water bottle and drain the tank by running water from the hot water faucet until no more wate...

Страница 17: ...Verify that all internal components are dry then reinstall the top panel 10 Reconnect brewer to electrical supply 11 Install the brew chamber without filter paper or grounds Run at least three full b...

Страница 18: ...STRICTOR BREW NOZZLE 1 41 83384 TUBE FAUCET SUPPLY METAL 1 42 85609 INSERT BREW OUTLET ELBOW 1 43 82241 FITTING BARBED BRASS 1 45 84619 SOLENOID BREW 240V 1 46 85634 TUBE BREW SILICONE 1 54 8043 12 GA...

Страница 19: ...3 31 85646 SWITCH BREW MOMENTARY 250V 1 32 8738 2 INDICATOR LIGHT GREEN 240V 1 35 82748 TIMER 8 MIN 1 36 8889 1 POWER CORD EURO 1 37 35 212 STRAIN RELIEF 1 45 84619 SOLENOID BREW 220 240V 1 50 86280 T...

Страница 20: ...LABEL 1 90 8706 76 BUTTON PLUG 1 1 8 3 8372CA 91 18 50 NUT WARMER PLATE RETAINING 1 4 28 3 8372CA 101 BASE BODY ASSEMBLY 1 102 BASE LOWER FRONT PANEL 1 103 BASE UPPER FRONT PANEL 1 104 BASE DOOR 1 10...

Страница 21: ...WIRING DIAGRAM 19...

Страница 22: ...c Division of Carrier Commercial Refrigeration In US and Canada Telephone 775 689 5700 Fax 888 492 2783 Fax 800 356 5142 website www wellsbloomfield com for orders only Bloomfield Industries proudly s...