background image

NOTE:  

For your protection, please note that equipment in 

this shipment was carefully inspected and packaged by 
skilled personnel before leaving the factory.   
Upon acceptance of this shipment, the transportation       
company assumes full responsibility for its safe delivery.

 

IF SHIPMENT ARRIVES DAMAGED:

 

1.

      VISIBLE LOSS OR DAMAGE:

    Be  certain  that  any 

         visible  loss  or  damage  is  noted  on  the  freight  bill  
         or express receipt, and that the note of loss or damage 
         is signed by the delivery person. 
2.     

FILE CLAIM FOR DAMAGE IMMEDIATELY: 

 

         Regardless of the extent of the damage. 

3.

CONCEALED LOSS OR DAMAGE: 

 if damage is 

        unnoticed until the merchandise is unpacked, notify the           
        transportation company or carrier immediately, and file    
        “CONCEALED DAMAGE” claim with them.  This 
        must be done within fifteen (15) days from the date the  
        delivery was made to you.  Be sure to retain the 
        container for inspection. 

 

Bloomfield Industries cannot assume liability for damage or 
loss incurred in transit.  We will, however, at your request, 
supply you with the necessary documents to support your 
claim. 

WARRANTY STATEMENT 

SERVICE POLICY AND PROCEDURE GUIDE 

ADDITIONAL WARRANTY EXCLUSIONS 

SHIPPING DAMAGE CLAIMS PROCEDURE 

1.     Resetting   of  safety  thermostats,  circuit breakers,  
         overload  protectors,  or  fuse  replacements  unless       
         warranted conditions are the cause. 
2.     All problems due to operation at voltages other than 
         specified  on  equipment  nameplates;  conversion  to     
         correct voltage must be the customer’s responsibility. 
3.     All problems due to electrical connections not made in 
        accordance  with  electrical  code  requirements  and  
         wiring diagrams supplied with the equipment. 
4.     Replacement of items subject to normal wear, to include 
         such items as knobs and light bulbs.  Normal maintenance 
          functions  including  adjustment  of  thermostats,  microswitches, 
          and replacement of fuses and indicating lights are not 
         covered under warranty. 
5.     All problems due to inadequate water supply, such as 
         fluctuating, or high or low water pressure. 
6.      All  problems  due  to  mineral/calcium  deposits,  or        
         contamination  from  chlorides/chlorines.  De-liming  is   
         considered  a  preventative  maintenance  function  and  is 
         not covered by warranty. 

All electrical equipment manufactured by BLOOMFIELD 

 

 

 

INDUSTRIES is warranted against defects in materials and 
workmanship for a period of one year from the date of original 
installation or eighteen (18) months from the date of shipment 
from our factory, whichever comes first, and is for the benefit 
of the original purchaser, except that: 
a.     airpots carry a 30 day parts warranty only. 
b.

dispensers; i.e., tea and coffee carry a 90  days parts      

        warranty only, excludes decanters. 

 
THE FOREGOING OBLIGATION IS EXPRESSLY GIVEN IN 
LIEU OF ANY OTHER WARRANTIES, EXPRESSED OR 
IMPLIED,  INCLUDING  ANY IMPLIED WARRANTY OF  
MERCHANTABILITY OR FITNESS FOR A PARTICULAR 
PURPOSE, WHICH ARE HEREBY EXCLUDED.   
 
BLOOMFIELD  INDUSTRIES  DIVISION  /  SPECIALTY  
EQUIPMENT MANUFACTURING CORPORATION SHALL 
NOT  BE  LIABLE  FOR  INDIRECT,   INCIDENTAL  OR 
CONSEQUENTIAL DAMAGES OR LOSSES FROM ANY 
CAUSE WHATSOEVER. 

 
This warranty is void if it is determined that upon inspection by 
an Authorized Service Agency that the equipment has been 
modified,  misused,  misapplied,  improperly  installed,  or     
damaged in transit or by fire, flood or act of God. 

It also does not apply if the serial nameplate has been       
removed or unauthorized service personnel perform service.  
The prices charged by Bloomfield Industries for its products 
are based upon the limitations in this warranty.  Seller’s     
obligation under this warranty is limited to the repair of defects 
without charge by a Bloomfield Industries Authorized Service 
Agency or one of its sub-agencies.  This service will be     
provided on customer’s premises for non-portable models.  
Portable models (a device with a cord and plug) must be 
taken or shipped to the closest Authorized Service Agency, 
transportation charges prepaid, for services. 

 
In addition to restrictions contained in this warranty, specific 
limitations are shown below (Additional Warranty Exclusions).  
Bloomfield Industries Authorized Service Agencies are located 
in principal cities. 

 
This warranty is valid in the United States and void elsewhere.  
Please consult your classified telephone directory or your food 
service equipment dealer; or, for information and other details 
concerning warranty, write to: 

 

Service Parts Department 

Bloomfield Industries 

P.O. Box 280 

Verdi, NV  89439 

  Phone:  (888) 492-2782                         Fax: (888) 492-2783

 

  7.   Full use, care and maintenance instructions are supplied 
         with  each  machine.    Those  miscellaneous  adjustments 
         noted  are  customer  responsibility.    Proper  attention  will 
         prolong the life of the machine. 
  8.  Travel  mileage is limited to  sixty (60)  miles from an   
         authorized Service Agency or one of its sub-agencies. 
  9.   All labor shall be performed during normal working hours.  
         Overtime premium shall be charged to the customer. 
10.   All genuine Bloomfield replacement parts are warranted 
 

       for ninety (90) days from date of purchase on non-

         warranted  equipment.   

Any use of non-genuine 

 

         Bloomfield parts completely voids any warranty

11.  Installation, labor and job check-out are not considered 
         warranty. 
12.  Charges incurred by delays, waiting time or operating 
         restrictions  that  hinder  the  service  technicians  ability  
        to  perform services  are  not  covered  by  warranty.  
         This  includes  institutional and correctional facilities. 

663  76061 Ow

ners 

M

a

n

ual for 

910

2A
 S

ingle Satellite Bre

w

er

 

Содержание 9102A

Страница 1: ...ANICAL CONTROL and EXTERNALLY HEATED SATELLITE SERVER MODEL 9102A 9104A Includes Installation Operation Use Care Servicing Instructions Model 9102A Satellite Brewer with 9105SS Satellite PRINTED IN UNITED STATES OF AMERICA p n 76061 Rev B ECN 12868 M663 050616 cps ...

Страница 2: ...s warranty only excludes decanters THE FOREGOING OBLIGATION IS EXPRESSLY GIVEN IN LIEU OF ANY OTHER WARRANTIES EXPRESSED OR IMPLIED INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE WHICH ARE HEREBY EXCLUDED BLOOMFIELD INDUSTRIES DIVISION SPECIALTY EQUIPMENT MANUFACTURING CORPORATION SHALL NOT BE LIABLE FOR INDIRECT INCIDENTAL OR CONSEQUENTIAL DAMAGES OR LOSSES ...

Страница 3: ...nner which will ensure its optimum performance WARRANTY STATEMENT xi SPECIFICATIONS 1 FEATURES OPERATING CONTROLS 2 PRECAUTIONS GENERAL INFORMATION 4 AGENCY APPROVAL INFORMATION 4 INSTALLATION 5 OPERATION 7 CLEANING INSTRUCTIONS 9 TROUBLESHOOTING SUGGESTIONS 11 SERVICING INSTRUCTIONS 12 EXPLODED VIEW BREWER 18 EXPLODED VIEW SATELLITE 21 SERVICE KITS 22 WIRING DIAGRAM 23 1 SPECIFICATIONS MODEL VOLT...

Страница 4: ...FEATURES AND OPERATING CONTROLS 2 Fig 1 SS 1 Satellite Brewing System Features Operating Controls 663 76061 Owners Manual for 9102A Single Satellite Brewer ...

Страница 5: ... voltage and wattage rating of brewer Press to start a brew Glows when water in tank is up to temperature Press to cancel a brew in progress Energizes satellite warmer Applies power to tank heater element Glows when ON Allows selection of 1 2 gallon or 1 gallon brew 9102A or 1 gallon or 1 1 2 gallon brew 9104A Holds coffee grounds during brew cycle Holds paper filter and coffee grounds in proper p...

Страница 6: ...h requires the use of tools must be performed by a qualified technician This manual is considered to be a permanent part of the appliance This manual and all supplied instructions diagrams schematics parts breakdown illustrations notices and labels must remain with the appliance if it is sold or moved to another location This appliance is made in the USA Unless otherwise noted this appliance has A...

Страница 7: ... copper tubing for installations exceeding 12 Brewer must be connected to a COLD water line NOTE DO NOT use a saddle tap for this water line connection A shut off valve must be installed between the main water supply and the brewer Plumbing installer must supply the shut off valve A 1 4 turn ball valve is recommended Brewer INLET FITTING is 1 4 Male Flare Fig 3 Water Line Installation Flush the wa...

Страница 8: ...Model 9104A 120 240 Volt AC 50 60 Hz 1ø 30 Amps 3 Wire L1 L2 Neutral Ground Fig 4 Model 9104A Terminal Block INITIAL SET UP INSTRUCTIONS Plumber s and Electrician s installation procedures must be completed before proceeding with the set up Be sure all electrical connections are secure and that all plumbing connections are secure and leak proof 1 CHECK BREWER FOR PROPER CONFIGURATION Make sure spr...

Страница 9: ...ersonal taste preferences To brew 1 2 gallon use 2 25 oz 64 gm of coffee To brew 1 gallon use 4 50 oz 128 gm of coffee To brew 1 1 2 gallon use 8 40 oz 240 gm of coffee Gently shake the basket to level the grounds Slide the brew chamber under the brew head Insert the Satellite Slide satellite under the brew chamber until it is fully seated Press WARMER switch ON 9102A Select Brew Volume Press VOLU...

Страница 10: ...herwise be too strong HOT WATER FAUCET Water for the hot water faucet is heated in a coil inside of the water tank The faucet volume may be controlled by adjusting the FAUCET NEEDLE VALVE Hot water is delivered at inlet line pressure and is approximately the same temperature as the brew water The time the BREW SOLENOID is open is controlled by the TIMER in response to the position of the VOLUME SE...

Страница 11: ... a mild detergent A bristle brush may be used to clean around the wire racks and bypass channels Rinse with clean water and allow to air dry Be sure wire rack is properly installed 8 Remove and drain the drip tray Rinse in a sink under warm running water Allow to air dry then reinstall on brewer 9 Wipe exterior of brewer and satellites with a soft clean cloth or sponge moistened with clean water 1...

Страница 12: ... 4 Run the sight glass brush up and down through the sight glass at least 10 times 5 Reinstall and tighten the shield cap 6 Drain sanitizer solution from satellite into the bucket 7 Disassemble faucet Brush clean with sanitizer solution Reassemble faucet 8 Install satellite on brewer 9 Rinse satellites With an empty brew chamber in place press the BREW key and run 1 full cycle into satellite 10 Dr...

Страница 13: ...amount and grind of coffee grounds per brew More than 1 filter paper or wrong type of filter paper used Use 1 genuine Bloomfield filter paper per brew Timer out of adjustment or damaged Check time Adjust or replace as needed Wire rack missing from brew chamber Check Replace if needed Insufficient brew volume all volumes Low inlet water pressure Other appliances on water line may be robbing pressur...

Страница 14: ...r screws BASIN sets in the body After disconnecting three hoses it may be lifted out TIMER ACCESS and HI LIMIT ACCESS PLUGS may be pried out with a thin flat blade screwdriver FRONT PANEL is attached with four screws SATELLITE WARMER PANEL is held by two spring clips After removing the front panel slide the warmer panel forward approximately 1 2 to release SATELLITE BRACKET is attached with two sc...

Страница 15: ...ture Turn COUNTER CLOCKWISE to decrease temperature 1 8 turn is equal to approximately 10ºF change 5 Turn POWER switch ON Press TANK HEATER switch to ON 6 Allow the brewer to come up to brewing temperature When READY TO BREW light comes on check temperature on thermometer Readjust thermostat as necessary 7 When desired temperature is achieved remove thermometer replace vent tube and reinstall top ...

Страница 16: ...mall flathead screwdriver Satellite or other container to calibrate volume 1 Press TANK HEATER switch to OFF 2 Remove TIMER ACCESS COVER on front panel Press VOLUME SELECTOR to 1 GAL position 3 Install an empty satellite and empty brew chamber 4 Press START BREW switch Brew should deliver 1 gallon 128 fl oz If adjustment is necessary turn TIMER knob Turn CLOCKWISE to increase time Turn COUNTER CLO...

Страница 17: ...wer 2 Remove SATELLITE BREW CHAMBER TOP PANEL and BASIN 3 Turn bypass adjustment screw several turns counter clockwise Insert and hold appropriate gauge fully into bypass valve from the outside of the brewer 4 Turn bypass adjustment screw clockwise until the resistance of the adjuster contacting the gauge is felt 5 Release the gauge set Turn bypass adjustment screw counterclockwise slowly until ga...

Страница 18: ...t the tank assembly at this time 3 Siphon all water from the hot water tank 4 Mix 2 gallons of deliming solution according to the manufacturer s directions Carefully pour the deliming solution into the water tank Lower the lid assembly back onto the tank Allow to sit for 30 minutes or as directed by the chemical manufacturer 5 At end of soaking period reconnect brewer to electrical power Install t...

Страница 19: ...ect brewer to electrical supply 14 Install the brew chamber without filter paper or grounds 15 Place an empty satellite under the brew chamber Run at least five 1 gallon brew cycles and discard all water generated at the end of each cycle Repeat for the other side 16 Rinse satellite with clean water Reinstall empty satellite under brew chamber Brewer is ready to use NOTE Normally silicone hoses do...

Страница 20: ...EXPLODED VIEW 18 PLUMBING COMPONENTS 663 76061 Owners Manual for 9102A Single Satellite Brewer ...

Страница 21: ...EXPLODED VIEW continued 19 ELECTRICAL COMPONENTS 663 76061 Owners Manual for 9102A Single Satellite Brewer ...

Страница 22: ...EXPLODED VIEW continued 20 CABINET RELATED COMPONENTS 663 76061 Owners Manual for 9102A Single Satellite Brewer ...

Страница 23: ...EXPLODED VIEW continued 21 SATELLITE ASSEMBLY 9105SS 663 76061 Owners Manual for 9102A Single Satellite Brewer ...

Страница 24: ...dle 82575 Seat Cup 82576 Faucet Repair Kit Includes Handle Seat Cup Spring Stem Pin Bonnet 82682 Retainer Clip 84804 Aerator Replacement Kit Includes O Ring Aerator Disk Aerator Cap 84870 Aerator Repair Kit Includes O Ring Aerator Disk FAUCET REPAIR KITS SOLENOID REPAIR KITS 85685 Solenoid Complete with Bypass 85218 Inlet Fitting Kit cap inlet fitting washer strainer 85219 Inlet Strainer ...

Страница 25: ...23 WIRING DIAGRAMS 663 76061 Owners Manual for 9102A Single Satellite Brewer ...

Страница 26: ...dustries Inc Division of Carrier Commercial Refrigeration In US and Canada Telephone 775 698 5700 Fax 888 492 2783 Fax 800 356 5142 website www wellsbloomfield com for orders only PRINTED IN UNITED STATES OF AMERICA ...

Отзывы: