SERVICING INSTRUCTIONS (continued)
REPLACE HEATING ELEMENT
Remove tank cover assembly (see page 13).
Remove two hex nuts holding element to cover. Pull element
from mounting holes.
Reassemble in reverse order.
REPLACE SOLENOID
Symptom: Automatic brewer will not flow water; or,
automatic brewer drips continuously from brew head.
Unplug power cord or turn circuit breaker
OFF
. Turn water
supply OFF.
Remove top panel.
Disconnect wiring from solenoid.
Unscrew water inlet piping from solenoid.
Remove two screws holding solenoid to bracket.
Remove brew and dilution manifold from solenoid, transfer
components to new solenoid
Transfer solenoid bracket to new solenoid.
Reassemble in reverse order.
REPLACE TIMER ASSEMBLY
Unplug power cord or turn circuit breaker OFF.
Remove top panel. Remove knob and three screws holding timer
to bracket. Disconnect wiring to timer.
Reassemble in reverse order.
Adjust timer as described on page 13
CLEAN STRAINER SCREEN
Unplug power cord or turn circuit breaker
OFF
. Turn water
supply OFF.
Remove bottom cap from strainer. Withdraw filter screen from
strainer body.
Clean screen with a suitable brush.
Reassemble in reverse order.
IMPORTANT:
When replacing
heating element, also replace
seal gaskets.
14
Fig. 12 Water Line Strainer
IL1680
606 Owners Manual for 8742-8748 T
ea Brewer 2M-761
16
606
Owners
Manual
for
8742-8748 T
ea
Brewer
2M-761
16
Содержание 8742 Series
Страница 4: ...FEATURES AND OPERATING CONTROLS 2 IL1673 606 Owners Manual for 8742 8748 Tea Brewer 2M 76116 ...
Страница 23: ...8742 8748 WIRING DIAGRAM 21 606 Owners Manual for 8742 8748 Tea Brewer 2M 76116 ...
Страница 24: ...10 Sunnen Drive St Louis MO 63143 telephone 314 678 6336 fax 314 781 2714 www bloomfieldworldwide com ...