Blonder tongue FRRA-S4A-860-43P Скачать руководство пользователя страница 5

5

FRRA Series  

Instruction Manual

    Model 

 

FRRA-S4A-860P

    Ch. Loading   

110 Ch.

    Output Level  

34/42

    Optical Input
  dBm 

mW

  -10 

0.10

  -9 

0.13

  -8 

0.16

  -7 

0.20

  -6 

0.25 

0 dB

  -5 

0.32 

2 dB

  -4 

0.40 

4 dB

  -3 

0.50 

6 dB

  -2 

0.63 

8 dB

  -1 

0.79 

10 dB

 

1.00 

12 dB

 

1.26 

14 dB

 

1.58 

16 dB

 

2.00 

18 dB

 

2.51

 

3.16

G

R
E
E

N

L
E

D

Increase Optical Input Power

Orange Optical LED Indication

Decrease Optical Input Power

Red Optical LED Indication

Approximate

External

Attenuator Value

Required

Attenuator Selection

The RF output level from the optical receiver module varies considerably over its operational optical input range.   

It is also dependent upon the transmitter’s channel loading, its resultant RF input level and the FRRA’s RF output 

capability. In order not to overload the amplifier section input, an attenuator must be installed in the “RF Loop” on 

the rear panel.  With the optical source and AC power connected, measure the RF signal level at “RF Loop” output  

connector. Choose the appropriate attenuator value to set this level to +5 dBmV, ± 5 dB. A Blonder Tongue model 

FAM-xx (Stock No. 4006A-xx) or equivalent attenuator can be used for this application. Install the attenuator on the 

RF loop output connector. Check that the d5 dBmV nominal signal level has been obtained, or change value 

accordingly. Install a coaxial jumper between the attenuator and the RF Loop input. Note that measured levels below 

0 dBmV (without attenuator) indicates a low optical input and should therefore be investigated. The FRRA gain and 

slope controls can now be adjusted for desired output.

Figure 4 - Configuration Table

Figure 5 - Rack Mount Rear Panel

BLONDER TONGUE

LABORATORIES, INC.

CAUTION:

FOR CONTINUED

PROTECTION AGAINST

FIRE HAZARD, REPLACE

ONLY WITH SAME TYPE FUSE

RF OUT

FRRA-S4S-860-43P

STOCK  NO. 7411P84BS  

FRRA-S4A-860-43P

STOCK  NO. 7411P84B  

OPTICAL

INPUT

117V, 

60 Hz

0.39A
0.75A

250V

SLO-

BLO

0 TO +10 dBmV

INPUT

OUTPUT

RF LOOP

FAM ATTENUATOR

(AS REQUIRED)

M A D E  I N  U S A

COAXIAL JUMPER

Содержание FRRA-S4A-860-43P

Страница 1: ...ty of their respective owner FRRA Series Fiber Optic Receiver Distribution Amplifiers Model Stock No FRRA S4A 860 43P 7411 P84 B FRRA S4S 860 43P 7411 P84 BS 651210200B The optical emission from the units are laser based and may present eye hazards if improperly used As always be careful when working with optical fibers Fibers can cause painful injury if they penetrate the skin NEVER USE ANY KIND ...

Страница 2: ...asers e g 780 nm are visible and are very damaging Always use instruments such as an optical power meter to verify light output NEVER NEVER NEVER look into the end of a fiber on a power device with ANY sort of magnifying device This includes microscopes eye loupes and magnifying glasses This WILL cause permanent irreversible burn on your retina Always double check that power is disconnected before...

Страница 3: ...Second Order CSO a b c 58 Hum Modulation 70 The FRRA is a fiber optic receiver integrated with the Blonder Tongue RMDA rack mount distribution amplifier The FRRA may be used as a launch amplifier in a coaxial distribution network after networking with fiber The fiber receiver provides a robust system for transferring 110 channels depending on model VSB AM modulated signals over a single mode fiber...

Страница 4: ...ould result This product conforms to European Community Directive 89 336 EE C for electromagnetic compatibility requirements 20 18 16 14 12 10 8 6 4 2 0 2 4 6 8 10 Figure 1 End to End Link Operating Instructions The optical emission from the units are laser based and may present eye hazards if improperly used As always be careful when working with optical fibers Fibers can cause painful injury if ...

Страница 5: ...ower connected measure the RF signal level at RF Loop output connector Choose the appropriate attenuator value to set this level to 5 dBmV 5 dB A Blonder Tongue model FAM xx Stock No 4006A xx or equivalent attenuator can be used for this application Install the attenuator on the RF loop output connector Check that the desired 5 dBmV nominal signal level has been obtained or change value accordingl...

Страница 6: ...h alcohol 3 First clean the sides of the connector ferrule Place the connector ferrule in the tissue and apply pressure to the sides of the ferrule Rotate the ferrule several times to remove all contamination from the ferrule sides 4 Now move to a clean part of the tissue Be sure it is still saturated with alcohol and that it is still four layers thick Put the tissue against the end of the connect...

Страница 7: ...blems and Comments Problem LED Status Check Comments No optical power at the Node Orange Optical Power LED Check power at the Tx If there is power at the Tx verify proper fiber is connected to the node If the proper fiber is connected ensure the integrity of the fiber Signal out of node is noisy Orange Optical Power LED Check optical power input via power monitor jack at the node See Specification...

Страница 8: ... ...

Отзывы: