Product Introduction

The Clearview 4:2 SD receives up to twenty-four (24) H.264 AES-128 encrypted IP channels from the Technicolor COM3000/2000 

devices.
The Clearview 4:2 SD decrypts the AES-128 content into clear IP, transcodes the decrypted H.264 content into MPEG-2, 

while preserving the “forensic watermarking” and returns the content to the Technicolor COM3000/2000 devices as clear IP.

Before You Begin

Unpacking the Unit

You will find the following Items in the box: 

• 

Clearview 4:2 SD (QTY=1)

• 

Power Cord with IEC C13 line socket and 3-pin Type B NEMA 5 plug (QTY=1)

The Clearview 4:2 SD is designed to be installed in a standard 19-inch (483 mm) rack (EIA 310-D, IEC 60297, and DIN 41494 

SC48D).  

To install, secure the unit's front panel to the rack by inserting four (4) machine screws, with cup washers, through the 

four (4) mounting holes in the front panel. A 1RU open space is recommended above the unit for ventilation.

Step 1: Setup and Install of the Unit

1

To power the unit up, connect the IEC line cord to the receptacle on the rear panel. Then connect the other end to a 

120 VAC power outlet.  The input power receptacle is equipped with a fuse-holder and fuse (SLO-BLO, 3.0 Amp, 250V).

2

WARNING

For safe and reliable operation, the ground pin of the power cord must be grounded properly.

IMPORTANT NOTE BEFORE YOU BEGIN!

The Key2License from Technicolor is required and MUST be installed on the COM3000/2000 unit prior 

to setup of this unit. See 

Section 3

 of the User Manual for more information.

DO NOT BLOCK THE UNIT'S AIR INTAKE OR AIR DISCHARGE OPENINGS

The Unit performance will be degrated without proper ventilation.

Excessive heat will shorten the life of the unit.

Features:

• 

Decrypts Technicolor’s AES-128 encrypted H.264 video 

content.

• 

Unicast IP input that supports up to 24 SPTS H.264 HD 

programs

• 

Unicast IP output supports up to 24 SPTS MPEG-2 SD 

programs

• 

Preserves Technicolor’s embedded watermarking on 
outbound MPEG-2 video content

• 

Compatible with Technicolor’s COM3000 DirecTV receivers

• 

Easy-to-use GUI for monitoring & control

• 

24 front panel Status LEDs (one for each program stream) 
and 1 front panel Temperature LED

Содержание Clearview 4:2 SD

Страница 1: ...der H 264 to MPEG 2 SD Transcoder for up to 24xSPTS Channels Clearview 4 2 SD Quick Guide Blonder Tongue Labs Inc ISO 9001 2015 Certified P N 651245400A Rev 070921 All Rights Reserved Specifications subject to change without notice All trademarks are property of their respective owners ...

Страница 2: ...1 To power the unit up connect the IEC line cord to the receptacle on the rear panel Then connect the other end to a 120 VAC power outlet The input power receptacle is equipped with a fuse holder and fuse SLO BLO 3 0 Amp 250V 2 WARNING For safe and reliable operation the ground pin of the power cord must be grounded properly IMPORTANT NOTE BEFORE YOU BEGIN The Key2License from Technicolor is requi...

Страница 3: ...be found using the search box in the Start Menu or for Windows 8 x the Start Screen b Once open click on Change Adapter Settings on left hand side of the window c Right click on the Local Area Connection and then click on the Properties d A dialog box entitled Local Area Connection Properties will appear In this box double click on the Internet Protocol Version 4 TCP IPv4 e A dialog box entitled I...

Страница 4: ...tatus tab Status Page Full View Step 3 Login to the Controller An Ethernet Cable should be connected between your PC and the Control port on the unit Open a Web browser Chrome or Firefox recommended and type http 172 16 70 1 in to your web browser to view and configure your Clearview 4 2 SD Enter the username Admin and pass as the password and click LOG IN ...

Страница 5: ...anscoder used The page also features a recent logged message box beneath the main status area which shows the 10 most recent entries within the Event Log To see a more in depth log of event messages click the Log tab located on the right side of the navigation menu at the top System Page Full View The following Ethernet Settings can be changed IP address Subnet Mask Default Gateway and the Primary...

Страница 6: ...s in the Video Audio Pipeline Settings table located on the right side The corresponding tab is also highlighted for persistent indication of the Transcode pipeline settings currently being shown Step 5 Transcoder Configuration Transcoders Settings The final information to setup within the unit is located in the Transcoders Settings tab Transcoders Settings Page Example Pipeline Status States Ligh...

Страница 7: ... 0 3 The Management PC is configured to be at 192 168 3 5 with a subnet mask of 255 255 0 0 Note The subnet mask of the Video Source Sink device must be configured to be on the same subnet mask as the Management PC Accessing devices from the Management PC To access the Video Source Sink device go to http 192 168 3 18 To access the Clearview 4 2 SD unit go to http 192 168 6 71 Note Additional Clear...

Страница 8: ...entation Updates Download the latest User Manual PDF by visiting our website Navigate to the product page by entering the full Model Name or Stock Number in the search field Upon reaching the product page the User Manual download link will be located beneath the product image Firmware Updates are available under Tech Support in the Resources section of the website General instructions for the FTP ...

Отзывы: