5900 Series 
Instruction Manual

Safety Instructions

➥   

Elevated Operating Ambient - If installed in a closed or multi-unit rack assembly, the operating ambient temperature of the rack environment may be 

greater than room ambient. Therefore, consideration should be given to installing the equipment in an environment compatible with the maximum ambient 

temperature.

➥   

Reduced Air Flow - Installation of the equipment in a rack should be such that the amount of air flow required for safe operation of the equipment is not 

compromised.

➥   

Mechanical Loading - Mounting of the equipment in the rack should be such that a hazardous condition is not achieved due to uneven mechanical loading.

➥   

Circuit Overloading - Consideration should be given to the connection of the equipment to the supply circuit and the effect that overloading of the circuits 

might have on overcurrent protection and supply wiring. Appropriate consideration of equipment nameplate ratings should be used when addressing this 

concern.

➥   

Reliable Earthing - Reliable earthing of rack-mounted equipment should be maintained. Particular attention should be given to supply connections other than 

direct connections to the branch circuit (e.g. use of power strips).

➥ 

Read all safety and operating instructions before you operate the unit.

➥ 

Retain all safety and operating instructions for future reference.

➥ 

Heed all warnings on the unit and in the safety and operating instructions.

WARNING: TO PREVENT FIRE OR SHOCK HAZARD, DO NOT EXPOSE THIS UNIT TO RAIN OR MOISTURE

NOTE TO CATV SYSTEM INSTALLER

This reminder is provided to call the CATV System Installer’s attention to Article 820-40 of the NEC that provides guidelines for proper 
grounding and, in particular, specifies that the cable ground shall be connected to the grounding system of the building, as close to the 
point of cable entry as practical.

The STOP sign symbol is intended to alert you to the presence of REQUIRED operating and maintenance (servicing) 
instructions that if not followed, may result in product failure or destruction.

TO REDUCE THE RISK OF ELECTRICAL SHOCK, DO NOT REMOVE COVER FROM THIS UNIT.   

NO USER-SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.

General & Safety Instructions

The YIELD sign symbol is intended to alert you to the presence of RECOMMENDED operating and maintenance 
(servicing) instructions.

The LIGHTNING flash symbol is intended to alert you to the presence of uninsulated "dangerous voltage" within the 
product's enclosure that may be of sufficient magnitude to constitute a risk of electrical shock.

YOU SHOULD ALWAYS FOLLOW THESE INSTRUCTIONS TO HELP ENSURE

AGAINST INjURY TO YOURSELF AND DAMAGE TO YOUR EQUIPMENT.

Содержание BIDA 86B-30

Страница 1: ...d over a range of 10 dB in the forward path and 18 dB in the return path Gain and slope controls are located on the front panel for easy set up and ad just ment Two 30 dB backmatched test points are provided to permit testing without interruption of service In applications where input signals are too high or where greater cable equalization is necessary the BIDA ARP can be reconfig ured by using p...

Страница 2: ...operate the unit Retain all safety and operating instructions for future reference Heed all warnings on the unit and in the safety and operating instructions WARNING TO PREVENT FIRE OR SHOCK HAZARD DO NOT EXPOSE THIS UNIT TO RAIN OR MOISTURE NOTE TO CATV SYSTEM INSTALLER This reminder is provided to call the CATV System Installer s attention to Article 820 40 of the NEC that provides guidelines fo...

Страница 3: ...ring a lightning storm or when the unit is left unattended and unused for long periods of time unplug it from the wall outlet and disconnect the lines between the unit and the antenna This will prevent damage caused by lightning or power line surges Do not locate the antenna near overhead power lines or other electric light or power circuits or where it can fall into such power lines or circuits W...

Страница 4: ...E CONTROL CIRCUIT 54 MHz HPF2 42 MHz LPF2 ATT INPUT OUTPUT 30 dB TEST 54 MHz HPF1 42 MHz LPF1 ATT GAIN CONTROL FULL GAIN CONTROL RETURN AMPLIFIER J11 24V J13 P3 P1 FLAT ATTENUATOR PASSIVE PASSIVE ACTIVE ACTIVE P2 ON OFF J12 PASSIVE RETURN PATH NOTE Passive Return Path Short Plug P1 on J11 and P3 on J13 to passive and P2 on J12 to off Active Return Path Short Plug P1 on J11 and P3 on J13 to active ...

Страница 5: ...l dBmV 44 42 Composite Triple Beat dB CTB 48 56 50 60 Crossmodulation dB XMOD 48 56 54 60 2nd Order Composite dB CSO 54 58 56 8 5 129 44 56 61 58 60 Impedence ohms 75 Hum Modulation dB 70 65 Input Output Test Port Level dB 30 2 Input Output Test Port Return Loss dB 20 Operating Temperature Range 20 to 60 Power Requirements Wall Power Transformer 105 130 VAC 60 Hz 0 38 AMP MAX Size LxWxH 10 1 2 x 7...

Страница 6: ...k wise After in sert ing CableEqualizer rotate Cable Equalizer clamp counter clockwise so it lays atop the mount ing tab Tighten mounting screw to secure Ca ble Equalizer clamp po si tion View A Specify dB value BIDA FA Flat Attenuator Stock No 5411A Plug in flat attenuator pad for reducing forward and or return gain in BIDA series amplifiers The BIDA FA is avail able in fixed values of 1 20 dB in...

Страница 7: ...stered trademarks of Motorola Corp Rev 5 6 2009 Blonder Tongue Laboratories Inc Limited Warranty Blonder Tongue Laboratories Inc BT will at its sole option either repair or replace with a new or factory reconditioned product as BT may determine any product manufactured by BT which proves to be defective in materials or workmanship or fails to meet the specifications which are in effect on the date...

Страница 8: ...One Jake Brown Road Old Bridge NJ 08857 1000 USA 800 523 6049 732 679 4000 FAX 732 679 4353 www blondertongue com ...

Отзывы: