Note:   Field service information is provided only for qualified com mer cial equipment installation per son nel. 

 

There are no user ser vice able parts in the BIDA.

INFORMATION BELOW IS FOR QUALIFIED INSTALLATION PERSONNEL ONLY

THE BIDA AMPLIFIER CAN EASILY BE MOUNTED TO ANY FLAT SURFACE. FOUR PRE-DRILLED MOUNTING HOLES ARE PROVIDED. USE #10 SCREWS 

(NOT SUPPLIED).
Field Installable Optional Modules

.

 (Take care not to bend jack pins when plugging in modules - view orientation of pins through holes provided - pins are polarized to prevent wrong 

installation - see Location Diagram). Leakage-current and/or resistance measurements should be made by service technician after repairs are com-

pleted to determine that exposed parts are acceptably insulated from the supply circuit.

BIDA-RF Return Filter Set

Stock No. 54071

Plug-in return filter adds passive reverse path to BIDA series 

amplifiers. Each BIDA-RF Plug-in contains a high pass (47-750 MHz) 

and a low pass (5-30 MHz) filter element with a common (5-750 

MHz) connecting point. A sheet metal cover is mounted over the 

circuitry to improve stability and prevent accidental detuning during 

shipping, handling, and installation. The filters separate sub-band 

(return) signals from VHF (forward) signals for processing within the 

amplifier. Two identical BIDA-RF units in the set make an amplifier 

bi-directional. A passive-return jumper wire is supplied to complete 

the sub-band path. The jumper wire is to be inserted between J 12 

and J 16. (See location diagram). Before inserting filters, remove the 

two factory installed VHF (forward) bypass jumpers, W2 (between 

J1 & J2) and W5 (between J9 & J10) and remove any residual RTV 

sealant, used to hold jumpers in place, which remains on the board 

surface.

BIDA-RA Return Amplifier

Stock No. 5402

Plug-in return amplifier adds reverse path gain to BIDA series 

amplifiers. The BIDA-RA is a sub-band (5-30 MHz) amplifier with 

24 dB gain. It contains a 12 dB variable slope control and a 12 dB 

variable gain control. A BIDA-RF return filter set (54071) is required 

to complete the system. The passive return jumper is discarded.

BIDA-FA-(*) Flat Attenuator

Stock No. 5411

Plug-in flat attenuator pad for reducing forward gain in BIDA series 

amplifiers. The BIDA-FA is available in fixed values of 1 thru 20 dB in 

increments of 1 dB. Before inserting, remove the factory installed "0 

dB" jumper wire W3 (between J3 & J5) and remove any residual RTV 

sealant, used to hold jumpers in place, which remains on the board 

surface.

* Specify dB value.

BIDA-CE Cable Equalizer

 

Stock No. 5475 (for BIDA 550 MHz) = BIDA CE-5-(*)

Stock No. 5477 (for BIDA 750 MHz) = BIDA CE-7-(*)

Plug-in cable equalizer for increasing forward slope in BIDA 

series amplifiers. The BIDA-CE provides attenuation that varies 

inversely with frequency to correct inherent tilt of coaxial 

cable used in distribution systems. A sheet metal cover is 

mounted over the circuitry to improve stability while preventing 

accidental detuning during shipping, handling, and installation. 

The BIDA-CE is available in fixed values of 3, 6, 9, 12, 15 or 18 

dB. Before inserting, remove the factory installed “0dB” jumper 

wire W4 (between J6 

 

& J8) and remove any residual RTV sealant, used to hold jumpers 

in place, which remains on the board surface.

* Specify dB value.
Note:  The unit is shipped with 18 gauge jumpers which are not 

re-installable.  Do not remove jumpers except when installing 

optional equipment modules.

For future reference, it is recommended that the type and value 

of the accessories installed in the BIDA be marked in the space 

provided on the front panel. The full sized reproduction below 

may also be copied and used for that purpose.

Accessories Installed

Flat Attenuator  

____________dB

Cable Equalizer 

____________dB

Return Filter 

____________

Return Amplifier 

____________

INPUT

TEST POINT

PILOT LIGHT

RETURN AMPLIFIER

REVERSE SLOPE

REVERSE GAIN

AMPLIFIER BALANCE

(Factory Preset - Do Not Adjust)

FUSE

OUTPUT

TEST POINT

FORWARD GAIN

FORWARD SLOPE

CABLE EQUALIZER

Jumper Wire

(Alternate Config.)

Pin Jack Sockets

KEY:

RETURN FILTER

RETURN FILTER

FLAT ATTENUATOR

Figure 2. Module and Control Location Diagram (Top View)

Accessory Identification

Содержание BIDA 550-30

Страница 1: ...t particular requirements Push pull hybrid IC modules enable the BIDA to operate at high output levels while retaining low distortion characteristics The aluminum chassis is designed to provide excellent heat dissipation thus allowing operation at high ambient temperatures with no degradation of performance or reliability Features Externally Accessible Test Points Permit In Service Testing Aluminu...

Страница 2: ...e CATV System Installer s attention to Article 820 40 of the NEC that provides guidelines for proper grounding and in particular specifies that the cable ground shall be connected to the grounding system of the building as close to the point of cable entry as practical For all pluggable equipment the socket outlet shall be installed near the equipment and shall be easily accessible TO REDUCE THE R...

Страница 3: ...roper ventilation Do not mount equipment in the rack space directly above or below the unit You should always follow these instructions to help ensure against injury to yourself and damage to your equipment Operate the unit using only the type of power source indicated on the marking label Unplug the unit power cord by gripping the plug not the cord The unit is equipped with a three wire ground ty...

Страница 4: ... objects may touch dangerous voltage points or short out parts This could cause fire or electrical shock Do not attempt to service the unit yourself as opening or removing covers may expose you to dangerous voltage and will void the warranty Refer all servicing to authorized service personnel Unplug the unit from the wall outlet and refer servicing to authorized service personnel whenever the foll...

Страница 5: ...Weight 5 3 4 lbs 3 oz Plug In Accessories 1 Flat Attenuator 1 thru 20 dB 5411 2 Cable Equalizer 3 6 9 12 15 or 18 dB 5475 5477 3 Return Filters 5 30 MHz 54071 4 Return Amplifier 5 30 MHz 5402 Notes 1 S pecification chart represents overall performance between the BIDA amplifier s input and output connectors with various optional field installed modules 2 O ne way configuration represents basic amp...

Страница 6: ...and a 12 dB variable gain control A BIDA RF return filter set 54071 is required to complete the system The passive return jumper is discarded BIDA FA Flat Attenuator Stock No 5411 Plug in flat attenuator pad for reducing forward gain in BIDA series amplifiers The BIDA FA is available in fixed values of 1 thru 20 dB in increments of 1 dB Before inserting remove the factory installed 0 dB jumper wir...

Страница 7: ...re registered trademarks of Motorola Corp Blonder Tongue Laboratories Inc Limited Warranty Blonder Tongue Laboratories Inc BT will at its sole option either repair or replace with a new or factory reconditioned product as BT may determine any product manufactured by BT which proves to be defective in materials or workmanship or fails to meet the specifications which are in effect on the date of sh...

Страница 8: ...One Jake Brown Road Old Bridge NJ 08857 1000 USA 800 523 6049 732 679 4000 FAX 732 679 4353 www blondertongue com Printed in China ...