2.0  INSTALLATION

 (Continued)

The serial plate on the lower right side of the unit indicates the type of gas your unit is equipped
to burn.  Do 

NOT

 connect to any other gas type.

A ¾"  NPT line is provided at the rear for the connection.  Each unit is equipped with an internal
pressure regulator which is set for 4" W.C. manifold pressure for natural gas and 10" W.C.

 

for

propane gas.  Use 1/8" pipe tap on the burner manifold for checking pressure.

An adequate gas supply is imperative.  Undersized or low pressure lines will restrict the volume
of gas required for satisfactory performance.  A steady pressure, minimum 6" W.C. for natural
gas and minimum 11" W.C. for propane gas, is recommended.  With all units operating
simultaneously, the manifold pressure on all units should not show any appreciable drop.
Fluctuations of more than 25% on natural gas, and 10% on propane gas, will create pilot
problems and affect burner operating characteristics.  Contact your gas company for correct
supply line sizes.

Purge the supply line to clean out any dust, dirt, or other foreign matter before connecting the
line to the unit.  It is recommended that an individual manual shut off valve be installed in the
gas supply line to the unit.  Use pipe joint compound which is suitable for use with LP gas on all
threaded connections.  Test pipe connections thoroughly for gas leaks.

WARNING:  Never use an open flame to check for gas leaks.  Check
all connections for leaks using soapy water before use.

NOTICE:  If applicable, the vent line from the gas appliance pressure regulator
shall be installed to the outdoors in accordance with local codes or, in the
absence of local codes, with the 

National Fuel Gas Code, ANSI Z223.1/NFPA 54

,

or the 

Natural Gas and Propane Installation Code CSA B149.1

, as applicable.

NOTICE:  If this equipment is being installed at over 2,000 feet altitude and was
not so specified on order, contact service department.  Failure to install with
proper orifice sizing may void the warranty.

Содержание KLS-100G

Страница 1: ...FIRED TRI LEG STATIONARY KETTLE INSTALLATION OPERATION MAINTENANCE BLODGETT OVEN COMPANY www blodgett com 44 Lakeside Avenue Burlington Vermont 05401 USA Telephone 800 331 5842 802 860 3700 Fax 802 8...

Страница 2: ...an cause property damage injury or death Read the installation operating and maintenance instructions thoroughly before installing operating or servicing this equipment PURCHASER Instructions to be fo...

Страница 3: ...NTENTS DESCRIPTION PAGE 1 0 Service Connections 4 2 0 Installation 5 3 0 Operation 11 4 0 Cleaning Instructions 16 5 0 Maintenance 20 6 0 Service 21 7 0 Troubleshooting 25 Appendix A Material Safety D...

Страница 4: ...33 KLS 80G 92 5 8 2352 KLS 100G 88 2235 KLS 80G 2 51 FLANGED FOOT DETAIL 4 7 16 11mm HOLES ON 3 76 B C EQUALLY SPACED DIMENSIONS ARE IN INCHES MM Supply gas through 3 4 pipe Unless otherwise specified...

Страница 5: ...rotection of Commercial Cooking Operations The electrical diagram is located on the inside of the console control cover EXHAUST FANS AND CANOPIES Canopies are set over ranges ovens and kettles for ven...

Страница 6: ...as required and tighten locking nuts 4 Be certain to leave adequate clearances for cleaning maintenance and service 5 The pressure relief valve is located at the left rear of the unit This area shoul...

Страница 7: ...and affect burner operating characteristics Contact your gas company for correct supply line sizes Purge the supply line to clean out any dust dirt or other foreign matter before connecting the line...

Страница 8: ...vice or its associated piping to limit the appliance movement Restraint means may be connected to bracket mounted near gas supply connection If the unit is also equipped with an optional water fill va...

Страница 9: ...V three prong grounded receptacle A separate 15 amp supply is needed for each unit 1 208 240 VAC 60 Hz Single and Three Phase Units with this electrical rating are factory equipped with a transformer...

Страница 10: ...ng plate on unit 2 Verify correct voltage cycle and phase against rating plate on unit 3 Gas pressure 4 Internal gas connections 5 Internal electrical connections 6 Pilots adjustment and ignition 7 Bu...

Страница 11: ...e local gas company or gas supplier for service GAS CONTROL INSTRUCTIONS The units do not require lighting the pilot with a match A Lighting 1 Turn thermostat to OFF position and power switch to OFF p...

Страница 12: ...ting After three trials for ignition if flame is not established the unit will lockout shutting off all gas New installations where there may be a considerable amount of air in the gas line may requir...

Страница 13: ...d internal kettle operating temperature 5 Pressure Gauge The pressure gauge indicates the internal operating pressure of the kettle When cold the gauge should be in green vacuum zone below 0 psi If it...

Страница 14: ...e should have been installed If disconnection of the restraint is necessary reconnect this restraint after the appliance has been returned to its originally installed position After igniting the main...

Страница 15: ...le and add the remainder of the liquid Continue as per recipe instructions When browning meat bring the kettle up to temperature before adding This will seal the juices in the meat VENT SYSTEM At leas...

Страница 16: ...touch it 1 Rinse the inside of the kettle thoroughly and drain to remove any food particles 2 Using a nylon brush clean the kettle with a mild detergent and water Never use steel wool or scouring pow...

Страница 17: ...the plug to line up with the pin and pull with both hands It is important to use both hands because the plug is heavy 2 Put the plug in a plastic pail that contains a mild soap solution A plastic pail...

Страница 18: ...fe of the equipment could be adversely affected STAINLESS STEEL To remove normal dirt grease or product residue from stainless steel use ordinary soap and water with or without detergent applied with...

Страница 19: ...respond to this procedure calls for a vigorous scouring in the direction of the polish lines using SCOTCH BRITE scouring pads or a STAINLESS scouring pad in combination with a powdered cleanser Heat t...

Страница 20: ...s NOT RECOMMENDED to use cleaning agents that are corrosive Use of cleaning agents that contain chloride acids or salts are corrosive and may cause pitting and corrosion when used over a period of tim...

Страница 21: ...EGULATOR The gas pressure regulator is an integral part of the combination gas control located just behind the lower front access door The pressure regulator adjustment is on the lower right side of t...

Страница 22: ...sure switch mis adjustment are 1 Pressure relief valve opening especially on preheat from a cold start to 267 degrees Fahrenheit 130EC pressure switch set too high 2 Burners are being shut down by pre...

Страница 23: ...to its original position 10 Replace the front panel when adjustment is complete ADDING WATER It may be necessary to replenish water in the jacket when the low water indicator comes on Do so as follows...

Страница 24: ...ny loss in performance should return Should the kettle fail to maintain a vacuum after repeated attempts to establish vacuum further checks should be made to see if the pressure relief valve is leakin...

Страница 25: ...ted spark igniter sensor Faulty igniter cable shorting to ground Faulty gas control Excessive flame rollout on ignition carboning Natural gas unit on propane Excessive gas pressure Incorrect orifice s...

Страница 26: ...rta 780 998 8282 Sarnia Ontario 519 339 3711 Varennes Quebec 450 652 1000 Product DOWFROST HD HEAT TRANSFER FLUID DYED Product Code 04632 Effective Date 2 20 01 Date Printed 07 10 02 MSD 002239 DOW CH...

Страница 27: ...azards anticipated from swallowing small amounts incidental to normal handling operations INHALATION At room temperature vapours are minimal due to physical properties Mists may cause irritation of up...

Страница 28: ...dition to unidentified toxic and or irritating compounds Hazardous combustion products may include and are not limited to carbon monoxide and carbon dioxide OTHER FLAMMABILITY INFORMATION Violent stea...

Страница 29: ...hing includes fire fighting helmet coat pants boots and gloves If protective equipment is not available or not used fight fire from a protected location or safe distance 6 ACCIDENTAL RELEASE MEASURES...

Страница 30: ...OID Avoid use temperatures above 450EF 232EC Product can degrade at elevated temperatures Generation of gas during decomposition can cause pressure in closed systems INCOMPATIBILITY WITH OTHER MATERIA...

Страница 31: ...different locations Waste characterizations and compliance with applicable laws are the responsibility solely of the waste generator THE DOW CHEMICAL COMPANY HAS NO CONTROL OVER THE MANAGEMENT PRACTI...

Страница 32: ...to SARA Title III Section 313 supplier notification requirements SARA HAZARD CATEGORY This product has been reviewed according to the EPA Hazard Categories promulgated under Sections 311 and 312 of t...

Страница 33: ...ENVIRONMENTAL PROTECTION ACT CEPA This product contains one or more substances which are not listed on the Canadian Domestic Substances List DSL Contact your Dow representative for more information S...