Cable Connectors

Cables must have a male XLR connector on one end and a female XLR 

connector on the other end.  (Duh!)

CAUTION:

 Do not allow contact between the common and the 

fixture’s chassis ground. Grounding the common can cause a ground 

loop, and your fixture may perform erratically. Test cables with an 

ohm meter to verify correct polarity and to make sure the pins are not 

grounded or shorted to the shield or each other.

3-Pin???  5-Pin???  Huh?!?

If you use a controller with a 5 pin DMX output connector, you will need to use a 5 pin to 3 pin adapter.  

They are widely available over the internet and from specialty retailers  If you’d like to build your own, the 

chart below details a proper cable conversion:

Conductor

3-Pin Female 

(Output)

5-Pin Male 

(Input)

Ground/Shield

Pin 1

Pin 1

DMX Data (-)

Pin 2

Pin 2

DMX Data (+)

Pin 3

Pin 3

Not Used.

No Connection.

No Connection.

Not Used.

No Connection.

No Connection.

Take It To The Next Level:  Setting Up DMX Control

Step 1: 

Connect the male connector of the 

DMX cable to the female connector (output) 

on the controller.

Step 2:

 Connect the female connector of 

the DMX cable to the first fixture’s male 

connector (input).  

Note:

  It doesn’t matter 

which fixture address is the first one 

connected.  We recommend connecting the 

fixtures in terms of their proximity to the 

controller, rather than connecting the lowest 

fixture number first, and so on.

Step 3:

 Connect other fixtures in the chain 

from output to input as above.  Place a DMX 

terminator on the output of the final fixture 

to ensure best communication.

Содержание snowblind

Страница 1: ...Blizzard Lighting LLC www blizzardlighting com Waukesha WI USA Copyright c 2012...

Страница 2: ...owBlind Pin up Picture 6 Rear Connections 6 3 Setup 7 Fuse Replacement 7 Connecting A Bunch Of SnowBlind s 7 Data DMX Cables 7 Cable Connectors 8 3 Pin 5 Pin Huh 8 Take It To The Next Level Setting up...

Страница 3: ...the rheostat or dimmer channel is used solely for a 0 to 100 switch AC Voltage Switch Not all fixtures have a voltage select switch so please verify that the fixture you receive is suitable for your...

Страница 4: ...me fuse size and type ALWAYS secure fixture using a safety chain NEVER carry the fixture by its cord Use its carrying handles DO NOT operate at ambient temperatures higher than 104 F 40 C In the event...

Страница 5: ...easy to use LED control panel menu Aluminum mounting bracket with locking knobs Lightweight and Compact It kept its New Years resolution The SnowBlind is a great little LED strobe fixture that packs...

Страница 6: ...Lighting LLC Figure 1 The SnowBlind Pin Up Picture 18x 1 Watt Cool White LED s Aluminum Housing LED Control Panel Figure 2 The Rear Connections AC Power In 3 Pin DMX512 In 3 Pin DMX512 Out Mounting Br...

Страница 7: ...s on a serial data link must be daisy chained in one single line Also connecting more than 32 fixtures on one serial data link without the use of a DMX optically isolated splitter may result in deteri...

Страница 8: ...d like to build your own the chart below details a proper cable conversion Conductor 3 Pin Female Output 5 Pin Male Input Ground Shield Pin 1 Pin 1 DMX Data Pin 2 Pin 2 DMX Data Pin 3 Pin 3 Not Used N...

Страница 9: ...y the fixtures that follow may also require a slave setting Check the Operating Adjustments section in this manual for complete instructions for this type of setup and configuration Mounting Rigging T...

Страница 10: ...g order The Control Panel LED Display shows the menu items listed on the Control Panel Menu Structure below Pushing the MODE button repeatedly will scroll through the menu settings To edit one push th...

Страница 11: ...ck to ensure fixture is operating under correct mode IE sound active auto DMX Etc if applicable Chase Speed Too Fast Slow Check to ensure proper setup of speed adjustment No Power Check fuse AC cord a...

Страница 12: ...mer levels You can think of it as 512 faders on a lighting console connected to 512 light bulbs Each slider s position is sent over the data link as an 8 bit number having a value between 0 and 255 Th...

Страница 13: ...to 512 bytes of data Data pack ets are transmitted continuously As soon as one packet is finished another can begin with no delay if desired usually another follows within 1 ms If nothing is changing...

Страница 14: ...atisfaction and wow factor That s what it s all about after all Returns Gasp We ve taken a lot of precautions to make sure you never even have to worry about sending a defective unit back or sending a...

Страница 15: ...ion 25W Light Source LED 18x 1 Watt LED s Cool White 100 000 hours Optical Beam Angle 15 degrees Thermal Max Operating Temp 104 degrees F 40 degrees C ambient Control Protocol USITT DMX 512 DMX Channe...

Страница 16: ...Enjoy your product Our sincerest thanks for your purchase The team Blizzard Lighting...

Отзывы: