3. SETUP

Fuse Replacement

Remove the fuse holder from of its housing. Then take out the dam-

aged fuse from its holder and replace with exact same type of fuse. 

Reattach the fuse holder, and then reconnect power.

Connecting A Bunch of Lux Capacitor™ Fixtures

You will need a serial data link to run light shows using a DMX-512 

controller or to run shows on two or more fixtures set to sync in mas

-

ter/slave operating mode. The combined number of channels required 

by all the fixtures on a serial data link determines the number of fix

-

tures the data link can support.

Fixtures on a serial data link must be daisy chained in one single line. 

Also, connecting more than 32 fixtures on one serial data link without 

the use of a DMX optically-isolated splitter may result in deterioration 

of the digital DMX signal. The maximum recommended cable-run dis-

tance is 500 meters (1640 ft).  The maximum recommended number 

of fixtures on a serial data link is 32 fixtures.

Data/DMX Cabling

To link fixtures together you’ll need data cables.  You should use data-

grade cables that can carry a high quality signal and are less prone to 

electromagnetic interference.

For instance, Belden© 9841 meets the specifications for EIA RS-485 

applications. Standard microphone cables will “probably” be OK, but 

note that they cannot transmit DMX data as reliably over long distanc-

es.  In any event, the cable should have the following characteristics:

 

2-conductor twisted pair plus a shield

 

Maximum capacitance between conductors – 30 pF/ft.

 

Maximum capacitance between conductor & shield – 55 pF/ft.

 

Maximum resistance of 20 ohms / 1000 ft.

 

Nominal impedance 100 – 140 ohms

Before replacing the fuse, disconnect the power cord. 

ALWAYS replace it with the same type and rating.

Содержание Lux Capacitor

Страница 1: ...Blizzard Lighting LLC http www blizzardpro com Waukesha WI USA Copyright c 2019...

Страница 2: ...Bunch Of Lux Capacitor Fixtures 7 Data DMX Cables 7 Cable Connectors 8 3 Pin 5 Pin Huh 8 Take It To The Next Level Setting up DMX Control 8 Fixture Linking Master Slave Mode 9 Mounting Rigging 9 4 Op...

Страница 3: ...s suitable for your local power supply See the label on the fixture or refer to the fixture s specifications chart for more information A fixture s listed current rating is its average current draw un...

Страница 4: ...ion slots are blocked ALWAYS disconnect from the power source before servicing or replacing fuse and be sure to replace with same fuse size and type ALWAYS secure fixture using a safety chain NEVER ca...

Страница 5: ...tions PowerCon compatible AC power input output connections CONTROL Protocol USITT DMX 512 DMX channels 6 8 12 channel modes Easy to use 4 button control panel with LCD display Operating modes DMX512...

Страница 6: ...Lux Capacitor Pin Up Picture Figure 2 The Rear Connections 3 60W Warm White LEDs POWER IN POWER OUT FUSE 10A 250V DMX IN DMX OUT Power Output Power Input Fuse Holder 4 Button Menu DMX Inputs DMX Outp...

Страница 7: ...ly isolated splitter may result in deterioration of the digital DMX signal The maximum recommended cable run dis tance is 500 meters 1640 ft The maximum recommended number of fixtures on a serial data...

Страница 8: ...xture s Conductor 3 Pin Female Output 5 Pin Male Input Ground Shield Pin 1 Pin 1 Data 1 Primary Data Link Pin 2 Pin 2 Data 1 Primary Data Link Pin 3 Pin 3 Data 2 Optional Secondary Data Link Pin 4 Pin...

Страница 9: ...the Operating Adjustments section in this manual for com plete instructions for this type of setup and configuration Mounting Rigging This fixture may be mounted in any SAFE position provided there i...

Страница 10: ...cending order DOWN Scrolls through menu items and numbers in descending order ENTER Is used to select and confirm store the current selection The control panel LED display shows the menu items you sel...

Страница 11: ...FF Lamp Light Set ENTER 000 255 0 100 Language EN English CN Chinese Sensitivity ENTER Mic sensitivity 000 255 0 100 Dimmer Mode Slow Slow dimming speed Fast Fast dimming speed Dimmer Curve LNR Linear...

Страница 12: ...and press ENTER Manual Adjustments Allows individual adjustments to be made via the control panel menu Manual Test 1 Navigate the main menu to reach RunMode press ENTER 2 Use the UP DOWN buttons to h...

Страница 13: ...031 032 047 048 063 064 079 080 095 096 111 112 127 128 143 144 159 160 175 176 191 192 207 208 223 224 239 240 255 Built in Programs 1 Overrides Built in Programs 2 No Function Program 1 Program 2 Pr...

Страница 14: ...isfaction and wow factor That s what it s all about after all Returns Gasp We ve taken a lot of precautions to make sure you never even have to worry about sending a defective unit back or sending a u...

Страница 15: ...Control Protocol USITT DMX 512 DMX Channels 6 8 12 channel modes Input Output 3 5 pin XLR Male Female Other Operating Modes DMX512 master slave auto sound active Warranty 2 year limited warranty does...

Страница 16: ...Enjoy your product Our sincerest thanks for your purchase The team Blizzard Lighting...

Отзывы: