Blizzard HW400 Скачать руководство пользователя страница 3

 

 

ELECTRICAL 

Please ensure that the required voltage of the compressor is being supplied at all times. 
Low or high voltage can detrimentally affect the refrigeration unit. 
All units should be plugged into a grounded and properly-sized electrical outlet with 
appropriate overcurrent protection. Please refer to the electrical requirements on the 
nameplate of the unit. Please make sure that your unit has its own dedicated outlet. Do 
not use an extension cord. 

 

 

Adjusting the Set Temperature 

1.  Press  and  hold  the  set  button  for  3  seconds  till  the  C  led  starts  blinking  with  the 

current set temperature shown 

2.  Use the arrow keys to adjust to the required set temperature setting. 
3.  Press  the  set key to store,  then  leave for approx.  5 secs till the display shows the 

cabinet temperature, the cabinet will then cool down to the new set temperature. 

NOTE!

 The temperature shown on the display  will fluctuate during normal use as the 

unit regulates the cabinet temperature. 

 

LOADING PRODUCT 

Shelves have been factory-installed for your convenience. Before loading shelves, 
please be sure that all shelf clips are completely fastened in their correct locations. It is 
important that all shelves rest completely level before stocking your cabinet with product. 
In order to maintain correct air flow inside the unit, please be sure to leave 50 mm to 100 
mm of space between the back wall and stored product. Blocking the evaporator fans 
will result in a warmer cabinet temperature, and ultimately compressor failure. Products 
must be pre-chilled / pre-frozen before loading into the cabinet. 

 

All electrical work must be carried out by suitably qualified

 persons 

 

Содержание HW400

Страница 1: ...Storage Refrigerator Freezer Installation Operation Maintenance Manual HC Gas R290 used...

Страница 2: ...noises if surface is uneven unit may malfunction if surface is uneven Unlevel surfaces can cause the cabinet to twist and affect the door alignment Install the unit in an indoor well ventilated area u...

Страница 3: ...approx 5 secs till the display shows the cabinet temperature the cabinet will then cool down to the new set temperature NOTE The temperature shown on the display will fluctuate during normal use as th...

Страница 4: ...sive door openings should be avoided in order to maintain cabinet temperature and to reduce the possibility of coil freeze up SAFETY WARNING Please pay close attention to the safety notices in this se...

Страница 5: ...electrical cord REGULAR MAINTENANCE CLEANING THE CONDENSER COIL For efficient operation it is important that the condenser surface be kept free of dust dirt and lint We recommend cleaning the condens...

Страница 6: ...nce for solutions to common problems SYMPTOM POSSIBLE CAUSE CORRECTIVE ACTION Compressor not running Fuse blown or circuit breaker tripped Power cord unplugged Thermostat set too high Cabinet in defro...

Страница 7: ...A Temperature Range Capacity litres HW400 220 240V 50Hz R290 267 1 6 0 10 320 LW400 220 240V 50Hz R290 350 1 7 18 22 320 HS400 220 240V 50Hz R290 267 1 6 0 10 320 LS400 220 240V 50Hz R290 350 1 7 18 2...

Страница 8: ...regarding disposal of your appliance Local authorities are not obliged to dispose of commercial refrigeration equipment but may be able to offer advice on how to dispose of the equipment locally All p...

Отзывы: