Blizzard Flurry 5 Скачать руководство пользователя страница 8

Page 8

Flurry™ 5 User Manual Rev. A  

 

 

(c) 2013 Blizzard Lighting, LLC

Cable Connectors

Cables must have a male XLR connector on one end and a female XLR 

connector on the other end.  (Duh!)

CAUTION:

 Do not allow contact between the common and the fix

-

ture’s chassis ground. Grounding the common can cause a ground 

loop, and your fixture may perform erratically. Test cables with an 

ohm meter to verify correct polarity and to make sure the pins are not 

grounded or shorted to the shield or each other.

3-Pin???  5-Pin???  Huh?!?

If you use a controller with a 5 pin DMX output connector, you will need to use a 5 pin to 3 pin adapter.  

They are widely available over the internet and from specialty retailers  If you’d like to build your own, the 

chart below details a proper cable conversion:

Conductor

3-Pin Female 

(Output)

5-Pin Male 

(Input)

Ground/Shield

Pin 1

Pin 1

DMX Data (-)

Pin 2

Pin 2

DMX Data (+)

Pin 3

Pin 3

Not Used.

No Connection.

No Connection.

Not Used.

No Connection.

No Connection.

Take It To The Next Level:  Setting Up DMX Control

Step 1: 

Connect the male connector of the 

DMX cable to the female connector (output) 

on the controller.

Step 2:

 Connect the female connector of the 

DMX cable to the first fixture’s male connec

-

tor (input).  

Note:

  It doesn’t matter which 

fixture address is the first one connected.  

We recommend connecting the fixtures in 

terms of their proximity to the controller, 

rather than connecting the lowest fixture 

number first, and so on.

Step 3:

 Connect other fixtures in the chain 

from output to input as above.  Place a DMX 

terminator on the output of the final fixture 

to ensure best communication.

Содержание Flurry 5

Страница 1: ...Blizzard Lighting LLC www blizzardlighting com Wisconsin USA Copyright c 2013 Flurry...

Страница 2: ...e 9 Mounting Rigging 9 4 Operating Adjustments 10 The Control Panel 10 Control Panel Menu Structure 11 Additional User Adjustments 12 Setting the pan tilt Menu to inverting or non inverting 12 Setting...

Страница 3: ...e label on the fixture or refer to the fixture s specifications chart for more information A fixture s listed current rating is its average current draw under normal conditions Check the fixture or de...

Страница 4: ...ervicing or replacing fuse and be sure to replace with same fuse size and type ALWAYS secure fixture using a safety chain NEVER carry the fixture by its head Use its carrying handles DO NOT operate at...

Страница 5: ...via master slave or DMX Sound active in standalone or DMX ADDITIONAL FEATURES User selectable basic or advanced operating modes Compact and lightweight it kept its new year s resolution LED display me...

Страница 6: ...7 Channel Mode Channel What It Does 1 Pan 2 Tilt 3 Dimmer 4 Red Intensity 5 Green Intensity 6 Blue Intensity 7 Amber Intensity 8 White Intensity 7 15 watt 5 in 1 LED s Control Panel LED Readout Head...

Страница 7: ...xtures on one serial data link without the use of a DMX optically isolated splitter may result in deterioration of the digital DMX signal The maximum recommended cable run distance is 500 meters 1640...

Страница 8: ...ike to build your own the chart below details a proper cable conversion Conductor 3 Pin Female Output 5 Pin Male Input Ground Shield Pin 1 Pin 1 DMX Data Pin 2 Pin 2 DMX Data Pin 3 Pin 3 Not Used No C...

Страница 9: ...e Operating Adjustments section in this manual for com plete instructions for this type of setup and configuration Mounting Rigging This fixture may be mounted in any SAFE position provided there is e...

Страница 10: ...ascending order DOWN Scrolls through menu items and numbers in descending order ENTER Is used to select and confirm store the current selection The Control Panel LED Display shows the menu items you...

Страница 11: ...ernal microphone AuTo No YES Sets the fixture in Auto Run mode STbY No YES Sets the unit to enter Standby Mode when not receiving DMX signal other wise the unit will automatically enter Master Slave M...

Страница 12: ...il the display shows rSET 2 Press ENTER to confirm your selection TO ADJUST THE FIXTURE COLOR BALANCE Note This will adjust the LED intensity of the Red Green Blue Amber White LEDs for ALL operating m...

Страница 13: ...l it shows AuTo orSouN and press ENTER to confirm 2 Use the UP DOWN buttons to set to the desired position press ENTER to confirm Master Slave Mode Auto or Sound Active Allows you to link up to 32 uni...

Страница 14: ...8 000 255 White 0 100 DMX Channel Values 13 Channel Mode Channel Channel Value Does 1 000 255 Pan 2 000 255 Pan Fine 3 000 255 Tilt 4 000 255 Tilt Fine 5 000 010 011 255 Dimmer Strobe Closed Dimming 0...

Страница 15: ...heck AC cord and circuit for damage verify that moving parts are not restricted and that unit s ventilation is not obstructed Slow Movement Verify that 220V 110V switch is in the correct position if a...

Страница 16: ...r levels You can think of it as 512 faders on a lighting console connected to 512 light bulbs Each slider s position is sent over the data link as an 8 bit number having a value between 0 and 255 The...

Страница 17: ...12 bytes of data Data packets are transmitted continuously As soon as one packet is finished another can begin with no delay if desired usually another follows within 1 ms If nothing is changing i e n...

Страница 18: ...and wow factor That s what it s all about after all Returns Gasp We ve taken a lot of precautions to make sure you never even have to worry about sending a defective unit back or sending a unit in fo...

Страница 19: ...sumption 110W Light Source LED 7x15W 5 in 1 60 000 hours Optical Beam Angle 25 degrees Movement Range Pan 540 degrees Tilt 180 degrees Thermal Max Operating Temp 104 degrees F 40 degrees C ambient Con...

Страница 20: ...Enjoy your product Our sincerest thanks for your purchase The team Blizzard Lighting...

Отзывы: