The principle  of compression  refrigeration  consists  of   "compression

” ,   "condensation"  , 

" throttling

and " vaporization

. The compression is undertaken by compressor, the 

condensation is completed by condenser, the throttling valve is executed by capillary and 

the vaporization is implemented by evaporator. When the coolant is circulating in the 

closed refrigeration system, the compressor sucks coolant, which has absorbs heat in 

evaporator, the coolant becomes a high pressure and high temperature gas. In condenser, 

it dissipates heat in air, while the coolant is re-liquefied and throttled in capillary and then 

enters into evaporator with low pressure

The liquefied coolant quickly boils and vapo

r

izes 

into gas when the pressure suddenly drops. Meanwhile, it absorbs heat inside the 

refrigerator. And the compressor sucks the low pressure and low temperature  gaseous 

coolant.It is circulating in this way up to realization  of intended refrigeration. 

 
 

drying filter 

capillary device

 

 
 

(1)

 

<

 

,:

'

,

"

 

0

 

al

 

 
 

low 

pressure gas

 

temperature gas

 

 

Содержание BZ-CD100R

Страница 1: ...Refrigerator BZ CD100R BZ CD400R...

Страница 2: ...fect This appliance compliance with the requirement of directive 2006 42 EC Contents 2 General 2 Structure and Parts 3 Handle and Erection 3 Handle and Erection 4 Preparation and Power Supply 4 Prepar...

Страница 3: ...tem with blower forced air cooling The temperature is quite even inside the refrigerator 2 Double hollow transparent glasses are used on door and body It features an artistic and elegant appearance pe...

Страница 4: ...its surround space is too small to circulate air Well ventilation Always locate the refrigerator at a place with fine ventilation For the first time use wait for 2 hours after handling and then plug...

Страница 5: ...4...

Страница 6: ...to modify and store the displayed value Press button to exit the adjustment and display the cold room temperature 2 If no more button is pressed within 10 seconds the cold room temperature will be di...

Страница 7: ...e for their safety Children should be supervised to ensure that they do not play with the appliance The operation manual is not suitable for the persons including children with reduced physical sensor...

Страница 8: ...d it must be replaced by the manufacturer its service agent TroubleShooting _ Trouble Cause and Remedy No refrigeration Is the plug in socket well Is the fuse broken Is there no power Unsatisfactory r...

Страница 9: ...sorbs heat in evaporator the coolant becomes a high pressure and high temperature gas In condenser it dissipates heat in air while the coolant is re liquefied and throttled in capillary and then enter...

Страница 10: ...ted Frequency Hz 50 50 Type of Climate 6 4 Protected Mode I I Lamp Power W 6 LED 7 LED Rated Voltage V 220 240 220 240 Storage Volume L 100 360 Net Weight kg 50 127 Overall Dimension mm LxWxH 480x480x...

Страница 11: ...environmentally friendly way The cardboard may be used as scrap paper The protective foil and the foam cushions are CFC free Do not allow children to play with the packaging and destroy plastic bags s...

Отзывы: