Blizzard Lighting TOURnado IP BAY Скачать руководство пользователя страница 7

 
 

7

171-210 

Opening pulse(slow to fast) 

211-250 

Closing pulse(slow to fast) 

251-255 

No strobe 

CH8(CH8 

Prior to 

CH10) 

CH13 

(CH13 

Prior to 

CH15) 

0-5 

No effect 

6-10 

CT01(Call custom color in menu settint) 

11-15 

CT02 

16-20 

CT03 

21-25 

CT04 

26-30 

CT05 

31-35 

CT06 

36-40 

CT07 

41-45 

CT08 

46-50 

CT09 

51-55 

CT10 

56-60 

AUTO 1 

61-65 

AUTO 2 

66-70 

AUTO 3 

71-75 

AUTO 4 

76-80 

AUTO 5 

81-85 

AUTO 6 

86-90 

AUTO 7 

91-95 

AUTO 8 

96-100 

AUTO 9 

101-105  AUTO 10 

106-110  AUTO 11 

111-115  AUTO 12 

116-120  AUTO 13 

121-125  AUTO 14 

126-130  AUTO 15 

131-135  AUTO 16 

136-140  AUTO 17 

141-145  AUTO 18 

146-150  AUTO 19 

151-155  AUTO 20 

156-160  AUTO 21 

161-165  AUTO 22 

166-170  AUTO 23 

171-175  AUTO 24 

176-180  AUTO 25 

181-185  AUTO 26 

186-190  AUTO 27 

191-195  AUTO 28 

196-200  AUTO 29 

Содержание TOURnado IP BAY

Страница 1: ...1 TOURnado IP BAY Blizzard Lighting LLC www blizzardlighting com Waukesha WI USA Copyright c 2015 ...

Страница 2: ...MMING MODE SETTING 13 6 9 DISPLAY SETTING 13 6 10 CUSTOM COLOR SETTING 13 6 11 AUTO RUN SELF PROGRAM RUN 14 6 12 EDIT SELF PROGRAM 14 6 13 CHECK THE LIGHTING INFORMATION 14 6 14 LIGHTING SETTING PARAMETER RESET 14 6 15 PROG SELF PROGRAMMING PARAMETER RESET 15 6 16 LIGHTING PARAMETER DOWNLOADING EACH OTHER VIA DMX CABLE 15 7 Instruction for compatible Sweden DMX wireless module Error Bookmark not d...

Страница 3: ...The TOURNADO IP BAY fixtures feature 12x high output 5 in 1 RGBW UV LEDs and a highly durable cast aluminum housing They offer a long life span low power consumption great color mixing effects and are super bright It features awesome built in programs dimming strobe gradual change fading and much more Packing List TOURNADO IP BAY 1 PC DMX Signal Cable 1 Set Waterproof input power cable 1 PC User M...

Страница 4: ...ge is in the range of the request technical parameter Before the installation please check the light s fasteners and mechanical structure have been received in good condition and appear no damage This light is designed for indoor use working temperature is lower than 40 degree The fixtures maybe mounted in any position provided there is adequate room for ventilation Make sure there are no inflamma...

Страница 5: ... 63HZ Consume 300W Lamp Type 25W LED 5 in 1 R G B UV W 12PCS Life span 50000 100000hours PWM Dimmer 1500HZ 16666 grades Control Signal DMX512 Control mode stand alone master slaver Channel 16CH 11CH 10CH 11CH 6CH 5CH Function Effect dimmer strobe gradual change ...

Страница 6: ...ction DMX Channels 5CH 6CH 11CH 10CH 11CH 16CH Value Function CH1 CH1 CH1 CH1 0 255 Dim all CH1 CH2 CH2 0 255 R CH2 CH3 CH3 0 255 G CH3 CH4 CH4 0 255 B CH4 CH5 CH5 0 255 UV CH5 CH6 CH6 0 255 W CH1 CH2 CH2 0 255 R1 CH2 CH3 CH3 0 255 G1 CH3 CH4 CH4 0 255 B1 CH4 CH5 CH5 0 255 UV 1 CH5 CH6 CH6 0 255 W1 CH6 CH7 CH7 0 255 R2 CH7 CH8 CH8 0 255 G2 CH8 CH9 CH9 0 255 B2 CH9 CH10 CH10 0 255 UV 2 CH10 CH11 CH...

Страница 7: ...5 CT08 46 50 CT09 51 55 CT10 56 60 AUTO 1 61 65 AUTO 2 66 70 AUTO 3 71 75 AUTO 4 76 80 AUTO 5 81 85 AUTO 6 86 90 AUTO 7 91 95 AUTO 8 96 100 AUTO 9 101 105 AUTO 10 106 110 AUTO 11 111 115 AUTO 12 116 120 AUTO 13 121 125 AUTO 14 126 130 AUTO 15 131 135 AUTO 16 136 140 AUTO 17 141 145 AUTO 18 146 150 AUTO 19 151 155 AUTO 20 156 160 AUTO 21 161 165 AUTO 22 166 170 AUTO 23 171 175 AUTO 24 176 180 AUTO ...

Страница 8: ...n full Blue full White 0 step 52 90 Red 0 Green full Blue down White 0 proportional 91 Green Red 0 Green full Blue 0 White 0 step 92 130 Red up Green full Blue 0 White 0 proportional 131 Yellow Red full Green full Blue 0 White 0 step 132 170 Red full Green down Blue 0 White 0 proportional 171 Red Red full Green 0 Blue 0 White 0 step 172 210 Red full Green 0 Blue up White 0 proportional 211 Magenta...

Страница 9: ...mer mode which menu had set up 6 Display Operation instruction MENU access the menu or return to a previous menu option ENTER select the current menu option UP menu selection or parameter increments DOWN menu selection or parameters decrease Menu Tree TAB LEVEL1 LEVEL2 LEVEL3 LEVEL4 ADDR Address 001 512 STAT Static control R1 0 255 G1 0 255 B1 0 255 UV 1 0 255 W1 0 255 R2 0 255 G2 0 255 B2 0 255 ...

Страница 10: ...el mode 16CH 11CH 10CH 11CH 6CH 5CH DIM Dimming mode LIN linear SQR square law ISQR inverse square law SCUR S curve LIN linear smooth SQR square law smooth ISQR inverse square law smooth SCUR S curve smooth DISY Display set ON Permanent on 2 OFF 2 minutes off CTST Custom color set CT01 R 0 255 G 0 255 B 0 255 UV 0 255 W 0 255 CT10 AUTO Auto AT01 RUN RUN RUN RUN AT33 RUN ATSP Auto speed 0 255 S CHS...

Страница 11: ...ture2 xxxC POW Power reduction xxx LOAD Load ST L Setting load YES NO PR L Program load YES NO SEND Send YES NO Instructions When enter to the position displayed on the LED the light will automatically set as master and send data to external Other fixtures can receive this data and will synchronously running without manually set as slave When power cycle it will jump to the position and running ag...

Страница 12: ...Analog process of press the button on again after wireless module off 3 KEY similar as the build out kep 6 5 AUTO LOCK KEY SETTING 1 Press the ENTER button in LOCK menu then enter auto lock key setting 2 Press the UP DOWN button to select YES NO 3 Press the ENTER button to escape and save Instructions When set to YES it will lock automatically after two minutes to prevent accidental triggering flo...

Страница 13: ... DIM menu then enter to the dimming mode setting 2 Press the UP DOWN button to select LIN SQR ISQR SCUR LIN SQR ISQR and SCUR 3 Press the ENTER button to escape and save Illustrations When setting LIN SQR ISQR and SCUR in DIM menu there will be added a little delay dimming effect for smooth Dimming curve Linear curve square law curve Inverse Square law curve S curve 6 9 DISPLAY SETTING 1 Press the...

Страница 14: ...ton for confirmation and enter to the next menu 6 Then press the UP DOWN button to select RED1 TIME WAIT USE 7 Press the UP DOWN button to set up the parameter which are needed 8 Press the ENTER button t o escape and save Illustrations When USE is set to be NO or the parameter of TIME is 0 it will not run this scene When WAIT is set to be FADE time the running process isas the following chart show...

Страница 15: ...ustrations 1 Please disconnect the connection of projector and DMX console before sending the parameter 2 The information of ADDR CAL can t be sent can t be downloaded each other 3 There will be an automatic reset of the other projectors after receiving parameter correctly 7 Instruction for compatible Sweden DMX wireless module 1 There are 4 modes compatible Sweden receive mode green indicator com...

Страница 16: ... the fixtures work in master mode it will send out the signal for the slave synchronous with it To avoid the host signal and DMX512 signals interfere with each other should cut off the DMX512 signals The signal lines are longer than 60 meters 20 lamps should increase a signal amplifier 9 XLR cable connecting XLR cable The standard connection way of the XLR is one end connects to the male plug and ...

Страница 17: ...4W at the end of the DMX connecting as below The Conversion between 3 pin and 5 pin XLR If the output cable of DMX512 controller is the 5PIN please use 1pc 5PIN to 3PIN cable 10 Connecting picture Light connecting picture ...

Страница 18: ...g signal if it shows twinkling of the decimal point which in the lower right corner of the screen when exiting the screen saver Please check the DMX address setting of lighting is correct or not Check CHMD setting is correct or not Check SIGN setting is correct or not Please check whether the DMX line is near to the high voltage wire or not In that case it will damage or interfere the DMX electric...

Отзывы: