Blizzard Lighting The Puck 3NX Скачать руководство пользователя страница 3

Page 3

The Puck 3NX Manual Rev. B  

 

 

Copyright (c) 2011-2012 Blizzard Lighting, LLC

1. GETTING STARTED

What’s In The Box?

 

• 1 x Puck 3NX™ Flat LED PAR Fixture

 

• 1x Mounting Bracket & 2 Knobs

 

• 1x IEC Power Cord

 

• This Eloquently Written User Manual

Getting It Out Of The Box

Congratulations on purchasing the next generation of our best-selling fi xture 

ever!  We’ve completely redesigned the Puck3 to provide more output, more 

reliability and more features, all at the same great price!

Now that you’ve got The Puck 3NX™  (or hopefully, Pucks!), you should care-

fully unpack the box and check the contents to ensure that all parts are present 

and in good condition. If anything looks as if it has been damaged in transit, 

notify the shipper immediately and keep the packing material for inspection.  

Again, please save the carton and all packing materials. If a fi xture must be re-

turned to the factory, it is important that the fi xture be returned in the original 

factory box and packing.

Powering Up!

All fi xtures must be powered directly off a switched circuit and cannot be run 

off a rheostat (variable resistor) or dimmer circuit, even if the rheostat 

or dimmer channel is used solely for a 0% to 100% switch.  

AC Voltage Switch - Not all fi xtures have a voltage select switch, so please 

verify that the fi xture you receive is suitable for your local power supply.  See 

the label on the fi xture or refer to the fi xture’s specifi cations chart for more 

information.  A fi xture’s listed current rating is its average current draw under 

normal conditions. Check the fi xture or device carefully to make sure that if a 

voltage selection switch exists that it is set to the correct line voltage you will 

use.

Warning! Verify that the voltage select switch on your unit matches 

the line voltage applied. Damage to your fi xture may result if the line 

voltage applied does not match the voltage indicated on the voltage se-

lector switch. All fi xtures must be connected to circuits with a suitable 

Ground (Earthing).

Getting A Hold Of Us

If something is wrong, just give us a call or send an email.  We’ll be 

happy to help, honest.

Blizzard Lighting

W220 N1531 Jericho Ct. Suite E, Waukesha, WI 53186 USA

[email protected]

www.blizzardlighting.com

866.493.6025

Содержание The Puck 3NX

Страница 1: ...Blizzard Lighting LLC www blizzardlighting com Wisconsin USA Copyright c 2011 2012 ...

Страница 2: ...ference 3 and 6 Channel Modes 5 The Puck 3NX Pin up Picture 6 3 Setup 7 Fuse Replacement 7 Connecting A Bunch Of Puck 3NX LED PAR Cans 7 Data DMX Cables 7 4 Operating Adjustments 8 DMX Mode DMX Mode Selection 8 Master Slave Mode 8 Sound Active Mode 8 Custom Color Display 9 Fixture running hour display 9 Additional Operating Help 9 Using the Fixture With The wiCICLE Wireless DMX System 10 Troublesh...

Страница 3: ...tly off a switched circuit and cannot be run off a rheostat variable resistor or dimmer circuit even if the rheostat or dimmer channel is used solely for a 0 to 100 switch AC Voltage Switch Not all fixtures have a voltage select switch so please verify that the fixture you receive is suitable for your local power supply See the label on the fixture or refer to the fixture s specifications chart fo...

Страница 4: ...before servicing or replacing fuse and be sure to replace with same fuse size and type ALWAYS secure fixture using a safety chain NEVER carry the fixture by its cord Use its carrying handles DO NOT operate at ambient temperatures higher than 104 F 40 C In the event of a serious operating problem stop using the unit immediately NEVER try to repair the unit by yourself Repairs carried out by unskill...

Страница 5: ...urable acrylic lens protector for added LED protection 4 Button LED control panel for easy programming Light source 9x 3 watt TRI Color Edison Edixeon LEDs Dual bracket for flexibility in mounting Power outlet for fixture linking MAX 3A 120VAC Ultra quiet fan for cool operation all night long wiCICLE Enabled functionality allows plug and play operation with our wiCICLE Brand Wireless DMX system DM...

Страница 6: ... 2011 2012 Blizzard Lighting LLC Figure 1 The Puck 3NX Pin Up Picture Super Fly TRI Color LEDs Flat as a pancake Dual Mounting Yokes Figure 2 The Rear Connections AC Power In Out DMX In DMX Out LED Control Panel Microphone Acrylic Lens Protector ...

Страница 7: ...ore than 32 fixtures on one serial data link without the use of a DMX optically isolated splitter may result in deterioration of the digital DMX signal The maximum recommended cable run distance is 500 meters 1640 ft The maximum recommended number of fixtures on a serial data link is 32 fixtures Data DMX Cabling To link fixtures together you ll need data cables You should use data grade cables tha...

Страница 8: ...hout a controller 1 Use standard DMX cables to daisy chain your units together via the DMX con nector on the rear of the units 2 Choose a unit to function as the Master Select MAST The master unit must be the first unit Finally chain the units together using DMX cable Master SLNd then NASt to confirm 3 Select slave function by using the UP DOWN keys to reach SLAV in the Master Auto menu on the sla...

Страница 9: ...ue 255 after using this mode 1 Select NAnu from the control panel then hit ENTER 2 Choose rEd GrEE or bLuE then hit ENTER to confirm 3 Using the UP DOWN keys select the color you wish to display by varying Red Green Blue intensity between 0 and 255 then hit ENTER to confirm each color choice 4 Select Color preset mode as instructed above then select CoL 7 then ENTER to confirm To Show the Fixture ...

Страница 10: ...IRCUMSTANCES IS BLIZZARD LIGHTING RESPONSIBLE FOR ANY DAMAGE FROM SUCH OPERATION Fixtures bearing the above logo MUST only use cable and connec tors which separate chassis case ground from cable shielding Cabling with the shield connected to the connector s case chassis may cause malfunction and damage to the wiCICLE or fixture wiCICLE transmitters have additional power requirements and therefore ...

Страница 11: ... s proceed 1 Plug the wiCICLE Receiver into the DMX IN connector of the fixture and verify it is receiving power the STATUS LED should illuminate 2 Connect the AC DC adaptor to the the wiCICLE Transmitter and verify it is receiving power the STATUS LED should illuminate 3 Press the RECESSED SELECTOR BUTTON on the Transmitter to select the operating channel group The system will store this setting ...

Страница 12: ...wn Fuse Check AC cord and circuit for damage verify that moving parts are not restricted and that unit s ventilation is not obstructed Slow Movement Verify that 220V 110V switch is in the correct position if applicable Also check that speed channels are set appropri ately No Response to Audio Verify that the fixture is in Sound Active mode Adjust Audio Sensitivity If Applicable Fixture Not Respond...

Страница 13: ...ypical 3 pin mic cables although this does not conform to the defined standard DMX is connected using a daisy chain configuration where the source connects to the input of the first device the output of the first device connects to the input of the next device and so on The standard allows for up to 32 devices on a single DMX link Each receiving device typically has a means for setting the startin...

Страница 14: ... s satistfaction and wow factor That s what it s all about after all Returns Gasp We ve taken a lot of precautions to make sure you never even have to worry about sending a defective unit back or sending a unit in for service But like any complex piece of equipment designed and built by humans once in a while something doesn t go as planned If you find yourself with a fixture that isn t behaving l...

Страница 15: ... Optical Beam Angle 25 degrees 29 degree field Luminous Intensity 7 160 Lux 1m Full White Red 1 550 Lux 1m Green 2 250 Lux 1m Blue 2 930 Lux 1m Thermal Max Operating Temp 104 degrees F 40 degrees C ambient Control Protocol USITT DMX 512 DMX Channels 3 or 6 User Selectable Input 3 pin XLR Male Output 3 pin XLR Female Other Operating Modes Standalone Master Slave Sound Active Color Preset Standalone...

Страница 16: ...Enjoy your product Our sincerest thanks for your purchase The team Blizzard Lighting ...

Отзывы: