Blizzard Lighting streak G Скачать руководство пользователя страница 8

Page 8

G-Streak™ Mini Moving Head Beam - Rev. A    

 

(c) 2015 Blizzard Lighting, LLC

Cable Connectors

Cables must have a male XLR connector on one end and a female XLR 

connector on the other end.  (Duh!)

CAUTION:

 Do not allow contact between the common and the fix

-

ture’s chassis ground. Grounding the common can cause a ground 

loop, and your fixture may perform erratically. Test cables with an 

ohm meter to verify correct polarity and to make sure the pins are not 

grounded or shorted to the shield or each other.

3-Pin???  5-Pin???  Huh?!?

If you use a controller with a 5 pin DMX output connector, you will need to use a 5 pin to 3 pin adapter.  

They are widely available over the internet and from specialty retailers  If you’d like to build your own, the 

chart below details a proper cable conversion:

Conductor

3-Pin Female 

(Output)

5-Pin Male 

(Input)

Ground/Shield

Pin 1

Pin 1

DMX Data (-)

Pin 2

Pin 2

DMX Data (+)

Pin 3

Pin 3

Not Used.

No Connection.

No Connection.

Not Used.

No Connection.

No Connection.

Take It To The Next Level:  Setting Up DMX Control

Step 1: 

Connect the male connector of the 

DMX cable to the female connector (output) 

on the controller.

Step 2:

 Connect the female connector of the 

DMX cable to the first fixture’s male connec

-

tor (input).  

Note:

  It doesn’t matter which 

fixture address is the first one connected.  

We recommend connecting the fixtures in 

terms of their proximity to the controller, 

rather than connecting the lowest fixture 

number first, and so on.

Step 3:

 Connect other fixtures in the chain 

from output to input as above.  Place a DMX 

terminator on the output of the final fixture 

to ensure best communication.

Содержание streak G

Страница 1: ...Blizzard Lighting LLC www blizzardlighting com Waukesha WI USA Copyright c 2015...

Страница 2: ...Data DMX Cables 7 Cable Connectors 8 3 Pin 5 Pin Huh 8 Take It To The Next Level Setting up DMX Control 8 Fixture Linking Master Slave Mode 9 Mounting Rigging 9 Mounting Points 10 Clamp Mounting 11 S...

Страница 3: ...uitable for your local power supply See the label on the fixture or refer to the fixture s specifications chart for more information A fixture s listed current rating is its average current draw under...

Страница 4: ...ore servicing or replacing fuse and be sure to replace with same fuse size and type ALWAYS secure fixture using a safety chain NEVER carry the fixture by its head Use its carrying handles DO NOT opera...

Страница 5: ...eam gobo 8 facet prism with variable speed and direction 0 100 linear LED dimmer DMX recorder and edit function integrated 3 pin male female input and outputs PowerCon compatible AC power In Out conne...

Страница 6: ...g Head Beam Rev A c 2015 Blizzard Lighting LLC Figure 1 The G Streak Pin Up Picture Lens Menu Buttons LED Readout Figure 2 The Rear Connections DMX In Power Switch PowerCon Compatible In Out Head Arms...

Страница 7: ...n 32 fixtures on one serial data link without the use of a DMX optically isolated splitter may result in deterioration of the digital DMX signal The maximum recommended cable run distance is 500 meter...

Страница 8: ...u d like to build your own the chart below details a proper cable conversion Conductor 3 Pin Female Output 5 Pin Male Input Ground Shield Pin 1 Pin 1 DMX Data Pin 2 Pin 2 DMX Data Pin 3 Pin 3 Not Used...

Страница 9: ...ck the Operating Adjustments section in this manual for com plete instructions for this type of setup and configuration Mounting Rigging This fixture may be mounted in any SAFE position provided there...

Страница 10: ...ety inspection of all installation material and the fixture If you lack these qualifications do not attempt the installation yourself Improper installation can result in bodily injury Caution Please b...

Страница 11: ...ecure an appropriately rated clamp to the mounting bracket using an M10 screw fitted through the center hole of the bracket Securing the Fixture Regardless of the rigging option you choose for your fi...

Страница 12: ...rough menu options in descending order Used to select and store the current menu or option within a menu Access control panel functions using the four panel buttons located directly underneath the LCD...

Страница 13: ...ALON SO A Alone Setting MAST SO M Master Setting SEt MIC M XX 00 99 Mic Sensitivity LODA ON OFF Data Reload VER U 11 current Software Version CALI CODE 0 255 088 preset Security Code CH 1 0 255 Pan Ca...

Страница 14: ...t CW slow fast Rotation Stop Rainbow Effect CCW slow fast 4 6 000 004 005 009 010 014 015 019 020 024 025 029 030 034 035 039 040 044 045 049 050 054 055 059 060 064 065 069 070 074 075 079 080 084 08...

Страница 15: ...006 127 128 255 Prism Prism Off Prism On Prism Rotate slow fast 8 10 000 225 226 235 236 245 246 255 Pan Tilt Speed Speed fast slow Blackout by Movement Blackout by All Wheel Change No Function 9 11...

Страница 16: ...No Power Check fuse AC cord and circuit for malfunction Blown Fuse Check AC cord and circuit for damage verify that moving parts are not restricted and that unit s ventilation is not obstructed Slow...

Страница 17: ...cal 3 pin mic cables although this does not conform to the defined standard DMX is connected using a daisy chain configuration where the source connects to the input of the first device the output of...

Страница 18: ...wow factor That s what it s all about after all Returns Gasp We ve taken a lot of precautions to make sure you never even have to worry about sending a defective unit back or sending a unit in for se...

Страница 19: ...F 40 degrees C ambient Control Protocol USITT DMX 512 DMX Channels 9 11 channel Input 3 pin XLR Male Output 3 pin XLR Female Other Information I changed my password to incorrect so that when I forget...

Страница 20: ...Enjoy your product Our sincerest thanks for your purchase The team Blizzard Lighting...

Отзывы: