Blizzard Lighting Solar Ray Скачать руководство пользователя страница 13

Page 13

Solar Ray™ User Manual Rev. A  

 

 

© 2015 Blizzard Lighting, LLC

DMX Values In-Depth (25-Channel Mode), continued

Channel

Value

What It Does

23

000 <--> 255

LED 23 Intensity (0% <--> 100%)

24

000 <--> 255

LED 24 Intensity (0% <--> 100%)

25

000 <--> 255

LED 25 Intensity (0% <--> 100%)

 

Kling-Net/Art-Net™ Connections

Each cell in the tables below represent the 25 LEDs per linked fixture, and their auto-assigned channel 
values in a 9 fixture setup.

Fixture 1: LED CH

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

25

Fixture 2: LED CH

26

27

28

29

30

31

32

33

34

35

36

37

38

39

40

41

42

43

44

45

46

47

48

49

50

Fixture 3: LED CH

51

52

53

54

55

56

57

58

59

60

61

62

63

64

65

66

67

68

69

70

71

72

73

74

75

Fixture 4: LED CH

76

77

78

79

80

81

82

83

84

85

86

87

88

89

90

91

92

93

94

95

96

97

98

99

100

Fixture 5: LED CH

101 102 103 104 105

106 107 108 109 110

111 112 113 114 115

116 117 118 119 120

121 122 123 124 125

Fixture 6: LED CH

126 127 128 129 130

131 132 133 134 135

136 137 138 138 140

141 142 143 144 145

146 147 148 149 150

Fixture 7: LED CH

151 152 153 154 155

156 157 158 159 160

161 162 163 164 165

166 167 168 169 170

171 172 173 174 175

Fixture 8: LED CH

176 177 178 179 180

181 182 183 184 185

186 187 188 188 190

191 192 193 194 195

196 197 198 199 200

Fixture 9: LED CH

201 202 203 204 205

206 207 208 209 210

211 212 213 214 215

216 217 218 219 220

221 222 223 224 225

Содержание Solar Ray

Страница 1: ...Blizzard Lighting LLC www blizzardlighting com Waukesha WI USA Copyright c 2015...

Страница 2: ...placement 7 DMX 512 Connections 7 Data DMX Cables 7 Power Linking 7 Mounting Rigging 8 Making A Wall of Solar Ray Fixtures 8 Connection Example 9 4 Operating Adjustments 10 Navigating The Control Pane...

Страница 3: ...See the label on the fixture or refer to the fixture s specifications chart for more information A fixture s listed current rating is its average current draw under normal conditions Check the fixtur...

Страница 4: ...ng or replacing fuse and be sure to replace with same fuse size and type ALWAYS secure fixture using a safety chain NEVER carry the fixture by its cord DO NOT operate at ambient temperatures higher th...

Страница 5: ...nnels 6 25 Strobe Rate 0 20 Hz Strong cast aluminum housing Internal Protection IP20 Smooth dimming curve with flicker free operation 400Hz ADDITIONAL FEATURES High performance fanless convection cool...

Страница 6: ...n Up Picture 25x 3 Watt Edison Warm White LEDs Figure 2 The Rear Connections Strong Die Cast Aluminum Housing Signal Status LED Power In 3 Pin DMX In Mounting bracket with turn quick clamp bracket con...

Страница 7: ...the digital DMX signal The maximum recom mended cable run distance is 500 meters 1640 ft The maximum recommended number of items daisy chained on a serial data link is 32 units Data DMX Cabling To li...

Страница 8: ...the mounting bracket Adjust the desired inclination angle via the mounting bracket and tighten the bracket screws Connect the device to the mains with the power plug All devices must be powered direc...

Страница 9: ...hting LLC Connection Example Here is just one of many possible fixture connection setups No matter what type of configuration your choose to connect your fixtures together in always be sure that each...

Страница 10: ...selection UP Scrolls through menu items and numbers in ascending order DOWN Scrolls through menu items and numbers in descending order The control panel LCD display shows the menu items you select fro...

Страница 11: ...n slave mode use the UP DOWN buttons to navigate to Slave Mode and press the ENTER button Then use the UP DOWN buttons to highlight either Yes or No Press the ENTER button to confirm your choice Netwo...

Страница 12: ...Program 21 Program 22 Program 23 Program 24 Program 25 Program 26 Program 27 Program 28 Program 29 Program Mix Mode 6 000 255 Auto Program Speed Slow Fast DMX Values In Depth 25 Channel Mode Channel V...

Страница 13: ...0 Fixture 3 LED CH 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 Fixture 4 LED CH 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 Fixture 5 LED...

Страница 14: ...ed and that unit s ventilation is not obstructed Slow Movement Check that speed channels are set appropriately No Response to Audio Verify that the fixture is in Sound Active mode Fixture Not Respondi...

Страница 15: ...ge the same data will be sent out over and over again This is a great feature of DMX if for some reason the data is not interpreted the first time around it will be re sent shortly Not all 512 channel...

Страница 16: ...factor That s what it s all about after all Returns Gasp We ve taken a lot of precautions to make sure you never even have to worry about sending a defective unit back or sending a unit in for service...

Страница 17: ...F 40 degrees C ambient Control Protocol Art Net Kling Net USITT DMX 512 DMX Channels 6 25 Channels Input Output 3 pin XLR Male Female Other Operating Modes Standalone Master Slave Auto Sound Active Ot...

Страница 18: ...Page 18 Solar Ray User Manual Rev A 2015 Blizzard Lighting LLC This page intentionally left blank...

Страница 19: ...Page 19 Solar Ray User Manual Rev A 2015 Blizzard Lighting LLC This page intentionally left blank...

Страница 20: ...Enjoy your product Our sincerest thanks for your purchase The team Blizzard Lighting...

Отзывы: