5. APPENDIX

A Quick lesson On DMX

DMX covers (and is an abbreviation for) Digital MultipleXed signals. It is the most common 

communications standard used by lighting and related stage equipment.  

DMX provides up to 512 control “channels” per data link. Each of these channels was 

originally intended to control lamp dimmer levels. You can think of it as 512 faders on a 

lighting console, connected to 512 light bulbs. Each slider’s position is sent over the data 

link as an 8-bit number having a value between 0 and 255. The value 0 corresponds to the 

light bulb being completely off while 255 corresponds to the light bulb being fully on. 

DMX data is transmitted at 250,000 bits per second using the RS-485 transmission 

standard over two wires. As with microphone cables, a grounded cable shield is used to 

prevent interference with other signals.

There are five pins on a DMX connector: a wire for ground (cable shield), two wires for 

“Primary” communication which goes from a DMX source to a DMX receiver, and two 

wires for a “Secondary” communication which goes from a DMX receiver back to a DMX 

source. Generally, the “Secondary” channel is not used so data flows only from sources 

to receivers.  Hence, most of us are most familiar with DMX-512 as being employer over 

typical 3-pin “mic cables,” although this does not conform to the defined standard.

DMX is connected using a daisy-chain configuration where the source connects to the input 

of the first device, the output of the first device connects to the input of the next device, 

and so on. The standard allows for up to 32 devices on a single DMX link. 

Each receiving device typically has a means for setting the “starting channel number” that 

it will respond to. For example, if two 6-channel fixtures are used, the first fixture might 

be set to start at channel 1 so it would respond to DMX channels 1 through 6, and the next 

fixture would be set to start at channel 7 so it would respond to channels 7 through 12. 

Troubleshooting

Symptom

Solution

Fixture Auto-

Shut Off

Check the fan in the fixture.  If it is stopped or moving slower than 

normal, the unit may have shut itself off due to high heat.  This is to 

protect the fixture from overheating.  Clear the fan of obstructions, 

or return the unit for service.

Beam is Dim

Check optical system and clean excess dust/grime.  Also ensure that 

the 220V/110V switch is in the correct position, if applicable.

No Light Output

Check to ensure fixture is operating under correct mode, IE sound 

active/auto/DMX/Etc., if applicable.  Contact service for more infor

-

mation.

Chase Speed Too 

Fast/Slow

Check to ensure proper setup of speed adjustment.

No Power

Check fuse, AC cord and circuit for malfunction.

No Response to 

Audio

Verify that the fixture is in “Sound Active” mode.

Adjust Audio Sensitivity, If Applicable.

Fixture Not 

Responding / 

Responding Er

-

ratically

Make sure all connectors are seated properly and securely.

Use Only DMX Cables.

Install a Terminator.

Check all cables for defects.

Reset fixture(s).

Содержание SnowBank

Страница 1: ...Blizzard Lighting LLC www blizzardlighting com Waukesha WI USA Copyright c 2012...

Страница 2: ...7 Connecting A Bunch Of SnowBank Fixtures 7 Data DMX Cables 7 Cable Connectors 8 3 Pin 5 Pin Huh 8 Take It To The Next Level Setting up DMX Control 8 Fixture Linking Master Slave Mode 9 Mounting Riggi...

Страница 3: ...or dimmer circuit even if the rheostat or dimmer channel is used solely for a 0 to 100 switch AC Voltage Switch Not all fixtures have a voltage select switch so please verify that the fixture you rec...

Страница 4: ...ore servicing or replacing fuse and be sure to replace with same fuse size and type ALWAYS secure fixture using a safety chain NEVER carry the fixture by its cord Use its carrying handles DO NOT opera...

Страница 5: ...male input and 3 pin female output Dual mounting yoke allows flexibility in positioning Heavy duty black aluminum housing Optical Beam Angle 45 400hz flicker free LED drivers Light Source 32 3 watt T...

Страница 6: ...ght c 2012 Blizzard Lighting LLC Figure 1 The SnowBank Pin Up Picture High Power Tri Color LEDs Black Aluminum Casing Dual Mounting Brackets Figure 2 The Rear Connections Microphone LED Control Panel...

Страница 7: ...es on a serial data link must be daisy chained in one single line Also connecting more than 32 fixtures on one serial data link without the use of a DMX optically isolated splitter may result in deter...

Страница 8: ...u d like to build your own the chart below details a proper cable conversion Conductor 3 Pin Female Output 5 Pin Male Input Ground Shield Pin 1 Pin 1 DMX Data Pin 2 Pin 2 DMX Data Pin 3 Pin 3 Not Used...

Страница 9: ...k the Operating Adjustments section in this manual for complete instructions for this type of setup and configuration Mounting Rigging This fixture may be mounted in any SAFE position provided there i...

Страница 10: ...the various control panel menus MODE Is used to navigate the various modes SETUP Is used to enter into the selected mode setup UP Scrolls through menu items and numbers in ascending order DOWN Scroll...

Страница 11: ...o choose 26 channel DMX mode SLAu Sets the fixture to run in slave mode SU SU00 SU31 Built in sound active effects Colr r000 r255 Red color adjustment 0 100 9000 9255 Green color adjustment 0 100 b000...

Страница 12: ...the chase speed by selecting from SP01 slowest to SPFL fastest 3 To set the fixture to run just one of its 22 built in chase patterns use the MODE to scroll to Pr and hit SETUP Then use the UP DOWN bu...

Страница 13: ...55 Pixel 3 Blue Intensity 0 100 11 000 255 Pixel 4 Red Intensity 0 100 12 000 255 Pixel 4 Green Intensity 0 100 13 000 255 Pixel 4 Blue Intensity 0 100 14 000 255 Pixel 5 Red Intensity 0 100 15 000 25...

Страница 14: ...7 088 095 096 103 104 111 112 119 120 127 128 135 136 143 144 151 152 159 160 167 168 175 176 183 184 191 192 199 200 207 208 215 216 223 224 231 232 255 No Function Red Yellow Green Cyan Blue Purple...

Страница 15: ...ed using a daisy chain configuration where the source connects to the input of the first device the output of the first device connects to the input of the next device and so on The standard allows fo...

Страница 16: ...satisfaction and wow factor That s what it s all about after all Returns Gasp We ve taken a lot of precautions to make sure you never even have to worry about sending a defective unit back or sending...

Страница 17: ...0W Light Source LED 32 3 watt Tri Color LEDs 100 000 hours Optical Beam Angle 45 degree optics standard Thermal Max Operating Temp 104 degrees F 40 degrees C ambient Control Protocol USITT DMX 512 DMX...

Страница 18: ...Page 18 SnowBank User Manual Rev A Copyright c 2012 Blizzard Lighting LLC This page intentionally left blank...

Страница 19: ...This page intentionally left blank...

Страница 20: ...Enjoy your product Our sincerest thanks for your purchase The team Blizzard Lighting...

Отзывы: