3. SETUP

Fuse Replacement

CAUTION!  The ROCKLITE™ TRI utilizes a high-output switch-mode 

power supply with an internal fuse.  Under normal operating condi-

tions, the fuse should not require replacement.  The fuse is fi eld 

replaceable, however it is an advanced procedure suited to qualifi ed 

individuals.  Should your ROCKLITE™ fuse require replacement, please 

contact Blizzard Lighting for instructions, or to return your unit for 

service.

Connecting A Bunch of ROCKLITE™ TRI Fixtures
You will need a serial data link to run light shows using a DMX-512 

controller or to run shows on two or more fi xtures set to sync in mas-

ter/slave operating mode. The combined number of channels required 

by all the fi xtures on a serial data link determines the number of fi x-

tures the data link can support.

Fixtures on a serial data link must be daisy chained in one single line. 

Also, connecting more than 32 fi xtures on one serial data link without 

the use of a DMX optically-isolated splitter may result in deterioration 

of the digital DMX signal.

The maximum recommended cable-run distance is 500 meters (1640 

ft).  The maximum recommended number of fi xtures on a serial data 

link is 32 fi xtures.

Data/DMX Cabling
To link fi xtures together you’ll need data cables.  You should use data-

grade cables that can carry a high quality signal and are less prone to 

electromagnetic interference.

For instance, Belden© 9841 meets the specifi cations for EIA RS-485 

applications. Standard microphone cables will “probably” be OK, but 

note that they cannot transmit DMX data as reliably over long distanc-

es.  In any event, the cable should have the following characteristics:

 

2-conductor twisted pair plus a shield

 

Maximum capacitance between conductors – 30 pF/ft.

 

Maximum capacitance between conductor & shield – 55 pF/ft.

 

Maximum resistance of 20 ohms / 1000 ft.

 

Nominal impedance 100 – 140 ohms

Содержание ROCKLITE TRI LED

Страница 1: ...Blizzard Lighting LLC www blizzardlighting com Brookfield WI USA Copyright c 2011 ROCKLITE TRI...

Страница 2: ...nt 7 Connecting A Bunch Of ROCKLITE TRI LED PAR Cans 7 Data DMX Cables 7 Cable Connectors 8 3 Pin 5 Pin Huh 8 Take It To The Next Level Setting up DMX Control 8 Fixture Linking Master Slave Mode 9 Mou...

Страница 3: ...mer circuit even if the rheostat or dimmer channel is used solely for a 0 to 100 switch AC Voltage Switch Not all fixtures have a voltage select switch so please verify that the fixture you receive is...

Страница 4: ...fore servicing or replacing fuse and be sure to replace with same fuse size and type ALWAYS secure fixture using a safety chain NEVER carry the fixture by its cord Use its carrying handles DO NOT oper...

Страница 5: ...ave Built in sound active programs RGB color mixing ability in standalone mode ADDITIONAL FEATURES Rugged and well built It hits the gym regularly Light source 18x 9 watt Tri Color LEDs Internal Fan C...

Страница 6: ...v A Copyright c 2011 Blizzard Lighting LLC Figure 1 The ROCKLITE Pin Up Picture High Power TRI Color LEDs Spun Aluminum Enclosure Mounting Yoke Adjustment Lock ing Knobs Figure 2 The Rear Connections...

Страница 7: ...Fixtures on a serial data link must be daisy chained in one single line Also connecting more than 32 fixtures on one serial data link without the use of a DMX optically isolated splitter may result in...

Страница 8: ...ou d like to build your own the chart below details a proper cable conversion Conductor 3 Pin Female Output 5 Pin Male Input Ground Shield Pin 1 Pin 1 DMX Data Pin 2 Pin 2 DMX Data Pin 3 Pin 3 Not Use...

Страница 9: ...eck the Operating Adjustments section in this manual for com plete instructions for this type of setup and configuration Mounting Rigging This fixture may be mounted in any SAFE position provided ther...

Страница 10: ...DOWN Scrolls through menu items and numbers in descending order SAVE Is used to select and confirm store the current selection The Control Panel LED Display shows the menu items you select from the me...

Страница 11: ...e MENU d001 DMX Mode 3 Channel MENU a001 DMX Mode 7 Channel MENU FF01 FF99 Color Fade Mode MENU CC01 CC99 Color Snap Mode MENU b001 r255 Manual Adjustment Red SAVE g001 g255 Manual Adjustment Green SA...

Страница 12: ...ture in Flash Fade mode select FF01 FF99 Fade Mode slowest to fastest or CC01 CC99 To confirm press the SAVE button 2 To use the fixture in demo mode select dEoo then press the SAVE button to confirm...

Страница 13: ...Intensity DMX Values In Depth 7 Channel Mode Channel Channel Value Does 1 000 255 Full Color Dimming 2 000 255 Red Intensity 3 000 255 Green Intensity 4 000 255 Blue Intensity 5 000 255 Strobe Slow F...

Страница 14: ...Fuse Check AC cord and circuit for damage verify that moving parts are not restricted and that unit s ventilation is not obstructed Slow Movement Verify that 220V 110V switch is in the correct positi...

Страница 15: ...ical 3 pin mic cables although this does not conform to the defined standard DMX is connected using a daisy chain configuration where the source connects to the input of the first device the output of...

Страница 16: ...s satistfaction and wow factor That s what it s all about after all Returns Gasp We ve taken a lot of precautions to make sure you never even have to worry about sending a defective unit back or sendi...

Страница 17: ...00 hours Optical Beam Angle 25 degree optics standard 23 degree beam 26 degree field Luminous Intensity 17 040 Lux 1m 25 degree optics Thermal Max Operating Temp 104 degrees F 40 degrees C ambient Con...

Страница 18: ...Page 18 ROCKLITE TRI LED Manual Rev A Copyright c 2011 Blizzard Lighting LLC This page intentionally left blank...

Страница 19: ...This page intentionally left blank...

Страница 20: ...Enjoy your product Our sincerest thanks for your purchase The team Blizzard Lighting...

Отзывы: