Blizzard Lighting ROCKER PANEL RGBAW Скачать руководство пользователя страница 5

Page 9

ROCKER PANEL RGBAW Manual Rev. A  

 

 

Copyright (c) 2010 Blizzard Lighting, LLC

Fixture Linking (Master/Slave Mode)

1.  Connect the (male) 3 pin connector side of the 

DMX cable to the output (female) 3 pin connector of 

the fi rst fi xture.

2.  Connect the end of the cable coming from the 

fi rst fi xture which will have a (female) 3 pin connec-

tor to the input connector of the next fi xture con-

sisting of a (male) 3 pin connector. Then, proceed 

to connect from the output as stated above to the 

input of the following fi xture and so on.

A quick note:  Often, 

the setup for Master-

Slave and Standalone 

operation requires that 

the fi rst fi xture in the 

chain be initialized for 

this purpose via either 

settings in the control 

panel or DIP-switches. 

Secondarily, the fi xtures 

that follow may also re-

quire a slave setting. 

Check the “Operating Adjustments” section in this manual for com-

plete instructions for this type of setup and confi guration.

Mounting & Rigging
This fi xture may be mounted in any SAFE position provided there is 

enough room for ventilation.

It is important never to obstruct the fan or vents pathway. Mount the 

fi xture using a suitable “C” or “O” type clamp.  The clamp should be 

rated to hold at least 10x the fi xture’s weight to ensure structural sta-

bility.  Do not mount to surfaces with unknown strength, and ensure 

properly “rated” rigging is used when mounting fi xutres overhead.

Adjust the angle of the fi xture by loosening both knobs and tilting the 

fi xture. After fi nding the desired position, retighten both knobs.

•  When selecting installation location, take into consideration lamp 

replacement access (if applicable) and routine maintenance.
•  Safety cables MUST ALWAYS be used.
•  Never mount in places where the fi xture will be exposed to rain, 

high humidity, extreme temperature changes or restricted ventilation.

Page 10

             ROCKER PANEL RGBAW Manual Rev. A  

 

 

Copyright (c) 2010 Blizzard Lighting, 

LLC

4. OPERATING ADJUSTMENTS

The Dip Switches

All of the various functions of the ROCKER PANEL™ RGBAW are set up using 

the 10-position DIP switch located on the rear of the unit.  Using this set of 

switches, you can select several different standalone, master/slave and DMX 

operating modes.  The chart below describes the various operating modes and 
their respective DIP switch settings. 

Function

DIP 1

DIP 2

DIP 3

DIP 4

DIP 5

DIP 6

DIP 7

DIP 8

DIP 9

DIP 10

All Red

ON

All Green

ON

All Blue

ON

All Amber

ON

All White

ON

Strobes

Slow

Fast

Auto Chase

Slow

Med.

Fast

Hyper

ON

OFF

Sound Active

OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF

ON

OFF

Slave

ON

OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF

ON

DMX CH. #

1

2

4

8

16

32

64

128

256

ON

The Control Panel LED Display shows the menu items you select from 

the menu map on page #11. When a menu function is selected, the 

display will show immediately the fi rst available option for the selected 

menu function. To select a menu item, press <ENTER>.

Press the <MENU> button repeatedly until you reach the desired 

menu function. Use the <UP> and <DOWN> buttons to navigate the 

menu options. Press the <SAVE> button to select the menu function 

currently displayed, or to enable a menu option. To return to the previ-

ous option or menu without changing the value, press the 

<MENU> button.

Содержание ROCKER PANEL RGBAW

Страница 1: ...erence 5 The ROCKER PANEL Pin up Picture 6 3 Setup 7 Fuse Replacement 7 Connecting A Bunch Of ROCKER PANEL RGBAW 7 Data DMX Cables 7 Cable Connectors 8 3 Pin 5 Pin Huh 8 Take It To The Next Level Setting up DMX Control 8 Fixture Linking Master Slave Mode 9 Mounting Rigging 9 4 Operating Adjustments 10 Navigating The Dip Switches 10 DMX Mode 10 Master Slave Mode 10 Sound Active Mode 10 Standalone P...

Страница 2: ...ing A Hold Of Us If something is wrong just give us a call or send an email We ll be happy to help honest Blizzard Lighting PO Box 1874 Brookfield WI 53008 USA support blizzardlighting com www blizzardlighting com 414 979 5781 Page 4 ROCKER PANEL RGBAW Manual Rev A Copyright c 2010 Blizzard Lighting LLC SAFETY INSTRUCTIONS Please keep this User Guide for future use If you sell the unit to someone ...

Страница 3: ...ATURES Rugged and well built It hits the gym regularly Light source 288x 10mm 5 watt Edison LEDs Multiple mounting brackets for positioning flexibility DMX Quick Reference Channel What It Does 1 Red Intensity 2 Green Intensity 3 Blue Intensity 4 Amber Intensity 5 White Intensity 6 Dimmer 7 Color Macros 8 Strobe 9 Built In Programs Page 6 ROCKER PANEL RGBAW Manual Rev A Copyright c 2010 Blizzard Li...

Страница 4: ...vent the cable should have the following characteristics 2 conductor twisted pair plus a shield Maximum capacitance between conductors 30 pF ft Maximum capacitance between conductor shield 55 pF ft Maximum resistance of 20 ohms 1000 ft Nominal impedance 100 140 ohms Page 8 ROCKER PANEL RGBAW Manual Rev A Copyright c 2010 Blizzard Lighting LLC Cable Connectors Cables must have a male XLR connector ...

Страница 5: ...ed position retighten both knobs When selecting installation location take into consideration lamp replacement access if applicable and routine maintenance Safety cables MUST ALWAYS be used Never mount in places where the fixture will be exposed to rain high humidity extreme temperature changes or restricted ventilation Page 10 ROCKER PANEL RGBAW Manual Rev A Copyright c 2010 Blizzard Lighting LLC...

Страница 6: ...lear the fan of obstructions or return the unit for service Beam is Dim Check optical system and clean excess dust grime Also ensure that the 220V 110V switch is in the correct position if applicable No Light Output Check to ensure fixture is operating under correct mode IE sound active auto DMX Etc if applicable Contact service for more information Chase Speed Too Fast Slow Check to ensure proper...

Страница 7: ...o be output per packet and in fact it is very uncommon to find all 512 used The fewer channels are used the higher the refresh rate It is possible to get DMX refreshes at around 1000 times per second if only 24 channels are being trans mitted If all 512 channels are being transmitted the refresh rate is around 44 times per second In summary since its design and evolution in the 1980 s DMX has beco...

Страница 8: ...0 Am ber White Optical Beam Angle 25 degree optics 23 degree beam 27 degree field Luminous Intensity 6 180 Lux 1m 25 degree optics Thermal Max Operating Temp 104 degrees F 40 degrees C ambient Control Protocol USITT DMX 512 DMX Channels 9 Input 3 pin XLR Male Output 3 pin XLR Female Other Operating Modes Standalone Master Slave Sound Active Color Preset Coolness Factor Leventy Billion Percent Warr...

Отзывы: