Blizzard Lighting Q-Stick RGBW LED Скачать руководство пользователя страница 15

Page 15

Q-Stick™ RGBW Manual Rev. B 

 

 

Copyright (c) 2012 Blizzard Lighting, LLC

5. APPENDIX

A Quick Lesson On DMX

DMX (aka DMX-512) was created in 1986 by the United States Institute for Theatre 

Technology (USITT) as a standardized method for connecting lighting consoles to lighting 

dimmer modules. It was revised in 1990 and again in 2000 to allow more flexibility.  The 

Entertainment Services and Technology Association (ESTA) has since assumed control over 

the DMX512 standard.  It has also been approved and recognized for ANSI standard clas

-

sification.  

DMX covers (and is an abbreviation for) Digital MultipleXed signals. It is the most common 

communications standard used by lighting and related stage equipment.  

DMX provides up to 512 control “channels” per data link. Each of these channels was origi

-

nally intended to control lamp dimmer levels. You can think of it as 512 faders on a lighting 

console, connected to 512 light bulbs. Each slider’s position is sent over the data link as an 

8-bit number having a value between 0 and 255. The value 0 corresponds to the light bulb 

being completely off while 255 corresponds to the light bulb being fully on. 

DMX data is transmitted at 250,000 bits per second using the RS-485 transmission stan

-

dard over two wires. As with microphone cables, a grounded cable shield is used to prevent 

interference with other signals.

There are five pins on a DMX connector: a wire for ground (cable shield), two wires for 

“Primary” communication which goes from a DMX source to a DMX receiver, and two wires 

for a “Secondary” communication which goes from a DMX receiver back to a DMX source. 

Generally, the “Secondary” channel is not used so data flows only from sources to receiv

-

ers.  Hence, most of us are most familiar with DMX-512 as being employer over typical 

3-pin “mic cables,” although this does not conform to the defined standard.

DMX is connected using a daisy-chain configuration where the source connects to the input 

of the first device, the output of the first device connects to the input of the next device, 

and so on. The standard allows for up to 32 devices on a single DMX link. 

Each receiving device typically has a means for setting the “starting channel number” that 

it will respond to. For example, if two 6-channel fixtures are used, the first fixture might 

be set to start at channel 1 so it would respond to DMX channels 1 through 6, and the next 

fixture would be set to start at channel 7 so it would respond to channels 7 through 12.

The greatest strength of the DMX communications protocol is that it is very simple and 

robust.  It involves transmitting a reset condition (indicating the start of a new “packet”), 

a start code, and up to 512 bytes of data. Data packets are transmitted continuously. As 

soon as one packet is finished, another can begin with no delay if desired (usually another 

follows within 1 ms). If nothing is changing (i.e. no lamp levels change) the same data will 

be sent out over and over again. This is a great feature of DMX -- if for some reason the 

data is not interpreted the first time around, it will be re-sent shortly.

Not all 512 channels need to be output per packet, and in fact, it is very uncommon to find 

all 512 used.  The fewer channels are used, the higher the “refresh” rate. It is possible to 

get DMX refreshes at around 1000 times per second if only 24 channels are being trans

-

mitted. If all 512 channels are being transmitted, the refresh rate is around 44 times per 

second.

In summary, since its design and evolution in the 1980’s DMX has become the standard 

for lighting control.  It is flexible, robust, and scalable, and its ability to control everything 

from dimmer packs to moving lights to foggers to lasers makes it an indispensable tool for 

any lighting designer or lighting performer.

Содержание Q-Stick RGBW LED

Страница 1: ...Blizzard Lighting LLC www blizzardlighting com Brookfield WI USA Copyright c 2012...

Страница 2: ...Replacement 7 Connecting A Bunch Of Q Stick RGBW PAR Cans 7 Data DMX Cables 7 Cable Connectors 8 3 Pin 5 Pin Huh 8 Take It To The Next Level Setting up DMX Control 8 Fixture Linking Master Slave Mode...

Страница 3: ...ariable resistor or dimmer circuit even if the rheostat or dimmer channel is used solely for a 0 to 100 switch AC Voltage Switch Not all fixtures have a voltage select switch so please verify that the...

Страница 4: ...re servicing or replacing fuse and be sure to replace with same fuse size and type ALWAYS secure fixture using a safety chain NEVER carry the fixture by its cord Use its carrying handles DO NOT operat...

Страница 5: ...NAL FEATURES Compact all metal case is functional and stylish ladies End mounted 3 pin 5 pin DMX connectors and PowerCON com patible in out for tons of cabling flexibility Internal Fan Cooling Sturdy...

Страница 6: ...zard Lighting LLC Figure 1 The Q Stick Pin Up Picture High Power 4 in 1 LEDs Sturdy metal enclosure Mounting Yoke Adjustment Locking Knobs Figure 2 The Rear Connections 3 Pin 5 Pin DMX In Fan Guard PO...

Страница 7: ...xtures on one serial data link without the use of a DMX optically isolated splitter may result in deterioration of the digital DMX signal The maximum recommended cable run distance is 500 meters 1640...

Страница 8: ...d like to build your own the chart below details a proper cable conversion Conductor 3 Pin Female Output 5 Pin Male Input Ground Shield Pin 1 Pin 1 DMX Data Pin 2 Pin 2 DMX Data Pin 3 Pin 3 Not Used...

Страница 9: ...k the Operating Adjustments section in this manual for com plete instructions for this type of setup and configuration Mounting Rigging This fixture may be mounted in any SAFE position provided there...

Страница 10: ...N Scrolls through menu items and numbers in descending order ENTER Is used to select and confirm store the current selection The Control Panel LED Display shows the menu items you select from the menu...

Страница 11: ...11 UP DOWN ENTER A 001 A511 UP DOWN ENTER cH ENTER F 001 UP DOWN ENTER P 001 A 001 rL ENTER r000 r100 UP DOWN ENTER GL ENTER G000 G100 UP DOWN ENTER bL ENTER b000 b100 UP DOWN ENTER EL ENTER E000 U100...

Страница 12: ...S or FAdE To confirm press the ENTER button 2 Now use the UP DOWN buttons to select the desired speed from 000 slowest to 100 fastest then hit ENTER to confirm 3 To use the fixture in automatic mode s...

Страница 13: ...ar Strobe Slow Fast Random Str Slow Fast Open Red Intensity 2 000 255 Red Intensity Amber Intensity 3 000 255 Green Intensity White Intensity 4 000 255 Blue Intensity Dimmer 0 100 5 000 255 White Inte...

Страница 14: ...se Check AC cord and circuit for damage verify that moving parts are not restricted and that unit s ventilation is not obstructed Slow Movement Verify that 220V 110V switch is in the correct position...

Страница 15: ...al 3 pin mic cables although this does not conform to the defined standard DMX is connected using a daisy chain configuration where the source connects to the input of the first device the output of t...

Страница 16: ...satisfaction and wow factor That s what it s all about after all Returns Gasp We ve taken a lot of precautions to make sure you never even have to worry about sending a defective unit back or sending...

Страница 17: ...ing Temp 104 degrees F 40 degrees C ambient Control Protocol USITT DMX 512 DMX Channels 4 5 7 Input 3 pin 5 pin XLR Male Output 3 pin 5 pin XLR Female Other Operating Modes Standalone Master Slave Sou...

Страница 18: ...Page 18 Q Stick RGBW Manual Rev B Copyright c 2012 Blizzard Lighting LLC This page intentionally left blank...

Страница 19: ...This page intentionally left blank...

Страница 20: ...Enjoy your product Our sincerest thanks for your purchase The team Blizzard Lighting...

Отзывы: