Fuse Replacement

The Motif™ Metro utilizes a high-output switch-mode power supply with an 

internal fuse.  Under normal operating conditions, the fuse should not require 

replacement.  The fuse is field replaceable, however it is an advanced procedure 

suited to qualified individuals.  Should the fuse require replacement, please 

contact Blizzard Lighting for instructions, or to return your unit for service.

Connecting A Bunch of Motif™ Metro Fixtures

You will need a serial data link to run light shows using a DMX-512 controller 

or to run shows on two or more fixtures set to sync in master/slave operating 

mode. The combined number of channels required by all the fixtures on a serial 

data link determines the number of fixtures the data link can support.

Fixtures on a serial data link must be daisy chained in one single line. Also, 

connecting more than 32 fixtures on one serial data link without the use of a 

DMX optically-isolated splitter may result in deterioration of the digital DMX 

signal. The maximum recommended cable-run distance is 500 meters (1640 

ft).  The maximum recommended number of fixtures on a serial data link is 32 

fixtures.

Data/DMX Cabling

To link fixtures together you’ll need data cables.  You should use data-grade 

cables that can carry a high quality signal and are less prone to electromagnetic 

interference.

For instance, Belden© 9841 meets the specifications for EIA RS-485 

applications. Standard microphone cables will “probably” be OK, but note that 

they cannot transmit DMX data as reliably over long distances.  In any event, 

the cable should have the following characteristics:

 

2-conductor twisted pair plus a shield

 

Maximum capacitance between conductors – 30 pF/ft.

 

Maximum capacitance between conductor & shield – 55 pF/ft.

 

Maximum resistance of 20 ohms / 1000 ft.

 

Nominal impedance 100 – 140 ohms

Before replacing a fuse, disconnect the power cord. 

ALWAYS replace with the same type and rating of fuse.

3. SETUP

Содержание Motif Metro

Страница 1: ...Blizzard Lighting LLC http www blizzardpro com Waukesha WI USA Copyright c 2020 SUITABLE FOR OUTDOOR USE...

Страница 2: ...nt 7 Connecting A Bunch of Motif Metro Fixtures 7 Data DMX Cabling 7 Cable Connectors 8 3 Pin 5 Pin Huh 8 Take It To The Next Level Setting Up DMX Control 8 Fixture Linking M S Mode 9 Mounting Rigging...

Страница 3: ...packing Powering Up All fixtures must be powered directly off a switched circuit and cannot be run off a rheostat variable resistor or dimmer circuit even if the rheostat or dimmer channel is used so...

Страница 4: ...S disconnect from the power source before servicing ALWAYS secure mounted fixtures with a safety cable NEVER carry the fixture by its head Use its carrying handles DO NOT operate at ambient temperatur...

Страница 5: ...lt head Tough as nails aluminum ABS enclosure IP rated locking power and 3 pin DMX connections Dual omega brackets with 1 4 turn fasteners Control Protocol USITT DMX 512 DMX channels 4 6 9 channel mod...

Страница 6: ...r Manual Rev A 2020 Blizzard Lighting LLC The Rear Connections Motif Metro Pin Up Picture 60 10W 4 in 1 RGBW LEDs 180 Tilt Head Cast Aluminum ABS Enclosure Power In Power Out DMX In DMX Out 4 button L...

Страница 7: ...connecting more than 32 fixtures on one serial data link without the use of a DMX optically isolated splitter may result in deterioration of the digital DMX signal The maximum recommended cable run d...

Страница 8: ...rimary Data Link Pin 3 Pin 3 Data 2 Optional Secondary Data Link Pin 4 Pin 4 Data 2 Optional Secondary Data Link Pin 5 Pin 5 DMX OUT DMX IN First Fixture in Chain Next Fixture in Chain DMX OUT DMX IN...

Страница 9: ...fixture may be mounted in any SAFE position provided there is enough room for ventilation The fan or vents pathway must never obstructed A mounting bracket assembly is provided that secures the botto...

Страница 10: ...ut changing the value press the MENU button 4 OPERATING ADJUSTMENTS The Control Panel All of the features and different modes possible with this fixture are accessed by using the control panel on the...

Страница 11: ...Blue Intensity 0 255 6 White White Intensity 0 255 3 Auto 1 Run Mode Stop Flash Fade Pulse 2 Speed Auto Speed 0 255 4 System 1 Host Mode ON master OFF 2 Language English Chinese 3 Backlight Off Black...

Страница 12: ...ost Mode and then press ENTER Then highlight ON and press ENTER 4 On following fixtures verify that this setting is set to OFF 5 If the DMX signal is lost while operating it will default to the set Au...

Страница 13: ...nction Red Green Blue White Yellow Magenta Cyan 8 000 100 101 150 151 200 201 255 Auto Mode No Function Flash Fade Pulse 9 000 255 Auto Speed Speed slow fast Dimming Modes Allows users to set the fixt...

Страница 14: ...That s what it s all about after all Returns Gasp We ve taken a lot of precautions to make sure you never even have to worry about sending a defective unit back or sending a unit in for service But l...

Страница 15: ...4 in 1 RGBW LEDs Optical Beam Angle 40 beam angle Luminous Intensity 13 220 lux 2 5 meters 3 414 lux 5 meters 1 610 lux 7 5 meters 887 lux 10 meters Movement Range Tilt 180 manual tilt Thermal Max Ope...

Страница 16: ...Enjoy your product Our sincerest thanks for your purchase The team Blizzard Lighting...

Отзывы: