Page 15
Motif™ Atelier 16FX User Manual Rev. A
Copyright © 2018 Blizzard Lighting, LLC
Data Sync Feature:
Users can transfer their custom settings from one fixture to another via DMX.
1.) Disconnect fixtures from any DMX controllers, and link them together via DMX in/out.
2.) On the sending fixture (DMX out), navigate the main menu using the
<UP/DOWN>
buttons
to reach
SEND
, and press the
<ENTER>
button.
3.) Select
YES
, and press the
<ENTER>
button to begin the transfer.
4.) Information for
ADDR
(address),
CAL
(global intensity), or
ID
(Fixture ID) will not be sent.
5.) After the data has been transferred, the receiving fixture will be automatically be reset.
Fixture ID Settings:
ID settings give you the ability to assign ID numbers to individual or groups of fixtures for quick and easy
DMX control access. This is available in 72/40/24 and 16-channel DMX modes.
1.) Use the
<MENU>
and
<UP/DOWN>
buttons to navigate to
ID
and press
<ENTER>
.
2.) Now use the
<UP/DOWN>
buttons to select any ID value you would like to assign to this
fixture, and press the
<ENTER>
button to save it.
3.) While using a DMX channel mode where fixture ID control available, you can now set the
ID
Function
Slider
to a value ranging from
010-020
for “
1 ID control per each 1 digit”
, ex. 21 =
ID21, 22=ID22, or you can set the
ID FUNCTION
slider to a value ranging from
021-030
for
“
1 ID control per each 10 digit
” functionality, ex. 010 <--> 019 = ID1, etc.
4.) Now use the
ID Address
Slider
on your controller to select the fixture ID number (or ID
range) setup in steps 1 & 2, while keeping in mind the function method you selected in step 3.
5.) You should now have DMX control of any fixtures with this ID.
Fixture Information:
These are not editable features, they are for informational purposes only.
1.) Use the
<MENU>
and
<UP/DOWN>
buttons to navigate to
INFO
and press
<ENTER>
,
then use the
<UP/DOWN>
buttons to highlight
SOFT
,
TEMP
, or
POW
, and press
<ENTER>
.
2.) The
SOFT
information displays the current software version installed on the fixture,
TEMP
displays the temperature (C) of the LED board, and
POW
displays the fixtures current power
level setting. Normally, it will be at 100%... but this fixture has built-in overheat protection that
may automatically reduce the output level to 80%, or 50% in high temperature situations.