Blizzard Lighting LB HEX Скачать руководство пользователя страница 3

Page 3

LB-Hex User Manual Rev. B  

 

 

© 2017 Blizzard Lighting, LLC

1. GETTING STARTED

What’s In The Box?

 

 

• 1 x LB Hex™ Professional LED Fixture

 

• An Ever-So-Handy Power Cord

 

• This Lovely User Manual

Getting It Out Of The Box

 

Congratulations on your purchase of one super-cool 6-in-1 LED PAR can! Now that 

you’ve got your LB Hex™ (or hopefully, more!), you should carefully unpack the box 

and check the contents to ensure that all parts are present and in good condition. If 

anything looks as if it has been damaged in transit, notify the shipper immediately and 

keep the packing material for inspection. Again, please save the carton and all packing 

materials. If a fixture must be returned to the factory, it is important that the fixture be 

returned in the original factory box and packing.

Powering Up! 

All fixtures must be powered directly off a switched circuit and 

cannot be run off a 

rheostat (variable resistor) or dimmer circuit, even if the rheostat or dimmer 

channel is used solely for a 0% to 100% switch

.  

AC Voltage Switch -

 Not all fixtures have a voltage select switch, so please verify that 

the fixture you receive is suitable for your local power supply.  See the label on the 

fixture or refer to the fixture’s specifications chart for more information.  A fixture’s 

listed current rating is its average current draw under normal conditions. Check the 

fixture or device carefully to make sure that if a voltage selection switch exists that it is 

set to the correct line voltage you will use.

 

Warning! 

Verify that the voltage select switch on your unit matches the line 

voltage applied. Damage to your fixture may result if the line voltage applied 

does not match the voltage indicated on the voltage selector switch. All 

fixtures must be connected to circuits with a suitable Ground (Earthing).

Getting A Hold Of Us

If something is wrong, please just visit our website at www.blizzardlighting.

com and open a support ticket. We’ll be happy to help, honest.

Disclaimer:

 The information and specifications contained in this document are subject 

to change without notice. Blizzard Lighting™ assumes no responsibility or liability 

for any errors or omissions that may appear in this user manual. Blizzard Lighting™ 

reserves the right to update the existing document or to create a new document to 

correct any errors or omissions at any time. You can download the latest version of this 

document from www.blizzardlighting.com.

 

Author:

Date:

Last Edited:

Date:

J. Thomas

1/30/2015

J. Thomas

4/18/2017

Содержание LB HEX

Страница 1: ...Blizzard Lighting LLC www blizzardlighting com Waukesha WI USA Copyright c 2017...

Страница 2: ...uh 8 Take It To The Next Level Setting up DMX Control 8 Fixture Linking Master Slave Mode 9 Mounting Rigging 9 Using this fixture with the wiCICLE Wireless DMX System 10 4 Operating Adjustments 12 Nav...

Страница 3: ...er supply See the label on the fixture or refer to the fixture s specifications chart for more information A fixture s listed current rating is its average current draw under normal conditions Check t...

Страница 4: ...g or replacing fuse and be sure to replace with same fuse size and type ALWAYS secure fixture using a safety chain NEVER carry the fixture by its cord Use its carrying handles DO NOT operate at ambien...

Страница 5: ...Dual bracket for flexibility in mounting Flicker free constant current LED driver 3 pin male input and 3 pin female output PowerCon compatible AC power In Out connectors Can directly power the wiCICLE...

Страница 6: ...LC Figure 1 The LB Hex Pin Up Picture 12 6 in 1 RGBAW UV LEDs Heavy Duty Composite Housing Secure Grip Locking Knobs Figure 2 The Rear Connections Power Out DMX In DMX Out Microphone Power In Mic Sens...

Страница 7: ...erial data link must be daisy chained in one single line Also connecting more than 32 fixtures on one serial data link without the use of a DMX optically isolated splitter may result in deterioration...

Страница 8: ...e to build your own the chart below details a proper cable conversion Conductor 3 Pin Female Output 5 Pin Male Input Ground Shield Pin 1 Pin 1 DMX Data Pin 2 Pin 2 DMX Data Pin 3 Pin 3 Not Used No Con...

Страница 9: ...Operating Adjustments section in this manual for com plete instructions for this type of setup and configuration Mounting Rigging This fixture may be mounted in any SAFE position provided there is eno...

Страница 10: ...to a DMX chain Some of these programs will automatically run unless the fixture is set to slave mode These fixtures typically sense DMX automatically and switch to DMX mode upon receiving DMX signal o...

Страница 11: ...current selection UP Scrolls through menu items and numbers in ascending order DOWN Scrolls through menu items and numbers in descending order The control panel LED display shows the menu items you s...

Страница 12: ...rolled by any universal DMX controller Set the Starting DMX Address The default mode for the fixture is DMX so the first menu item that you can edit is the starting DMX address 1 Navigate the main men...

Страница 13: ...000 255 0 100 3 Press the ENTER button to confirm Blue 1 Navigate the main menu until you reach bL and press ENTER 2 Use the UP DOWN buttons to adjust blue 000 255 0 100 3 Press the ENTER button to c...

Страница 14: ...29 030 039 040 049 050 059 060 069 070 079 080 089 090 099 100 109 110 119 120 129 130 139 140 255 Programs Auto and Sound Active Dimmer Speed Program 1 R G B jump Program 2 R G B fade in out Program...

Страница 15: ...in mic cables although this does not conform to the defined standard DMX is connected using a daisy chain configuration where the source connects to the input of the first device the output of the fir...

Страница 16: ...tor That s what it s all about after all Returns Gasp We ve taken a lot of precautions to make sure you never even have to worry about sending a defective unit back or sending a unit in for service Bu...

Страница 17: ...ntless words Warranty 2 year limited warranty does not cover malfunction caused by damage to LEDs Troubleshooting Symptom Solution Fixture Auto Shut Off Check the fan in the fixture If it is stopped o...

Страница 18: ...m DISCLAIMER The power connector fitted to the fixture and fixture cord are designed for compatibility with products manufactured by Neutrik AG Neutrik USA and their related entities however they are...

Страница 19: ...compatible input 2 Upper lamp pressing plate 12 Red PVC 3 Under lamp pressing plate 13 PCB DMX canon socket 4 Lamps 14 Power supply 5 Copper pillar 15 Master PCB 6 PCB lamp board 16 Outer bracket 7 Ra...

Страница 20: ...Enjoy your product Our sincerest thanks for your purchase The team Blizzard Lighting...

Отзывы: