background image

Page 2

          Flurry TRI Manual Rev. A  

 

 

Copyright (c) 2011 Blizzard Lighting, LLC

TABLE OF CONTENTS

Flurry™ 

TRI 

      1

1. 

Getting 

Started 

     3

 What’s 

In 

The 

Box? 

    3

 

Getting It Out Of The Box   

 

 

 

3

 Powering 

Up! 

     3

 Getting 

Hold 

Of 

Us 

    3

 

Safety Instructions (Don’t Stick Your Hand In The Toaster!) 

4

2. Meet The Flurry™ TRI  

 

 

 

 

5

 Features 

      5

 

DMX Quick Reference (13-Channel Mode)    

 

5

 

DMX Quick Reference (5-Channel Mode)  

 

 

6

 The 

Flurry 

Pin-up 

Picture 

    6

3. 

Setup 

 

      7

 Fuse 

Replacement 

     7

 

Connecting A Bunch Of Flurry™ TRI Lumieres 

 

7

 Data/DMX 

Cables 

     7

 Cable 

Connectors 

     8

 3-Pin??? 

 

5-Pin??? 

 

Huh? 

    8

 

Take It To The Next Level:  Setting up DMX Control   

8

 

Fixture Linking (Master/Slave Mode) 

 

 

9

 Mounting/Rigging 

     9

4. 

Operating 

Adjustments 

 

    10

 The 

Control 

Panel 

   

   10

 Control 

Panel 

Menu 

Structure 

   11

 Additional 

User 

Adjustments 

   12

 

Setting the pan/tilt/Menu to inverting or non-inverting 

12

 

Setting the DMX channel confi 

guration 

 

  12

 

Setting the maximum pan angle 

  

 

 

12

 

Setting the maximum tilt angle  

 

 

 

12

 Service 

Functions 

     12

 Resetting 

the 

fi 

xture 

    12

 Restoring 

Factory 

Defaults 

    12

 Stand-Alone 

(“Auto”) 

Mode 

    13

 

Master/Slave (“Auto” or “Sound Active”) 

 

 

13

 Easy 

Controller 

Mode 

 

    13

 DMX 

Mode 

 

     13

 

DMX Channel Values In-Depth (13-Channel Mode) 

 

14

 

DMX Channel Values In-Depth (5-Channel Mode) 

 

15

 Troubleshooting 

 

     16

5. 

Appendix 

 

      17

 A 

Quick 

DMX 

Lesson 

    17

 

Keeping Your Flurry As Good As New 

 

 

18

 Returns 

(Gasp!) 

 

     18

 Shipping 

Issues 

     18

 Tech 

Specs 

 

     19

Содержание Flurry TRI

Страница 1: ...Blizzard Lighting LLC www blizzardlighting com Brookfield WI USA Copyright c 2011 ...

Страница 2: ...ing up DMX Control 8 Fixture Linking Master Slave Mode 9 Mounting Rigging 9 4 Operating Adjustments 10 The Control Panel 10 Control Panel Menu Structure 11 Additional User Adjustments 12 Setting the pan tilt Menu to inverting or non inverting 12 Setting the DMX channel configuration 12 Setting the maximum pan angle 12 Setting the maximum tilt angle 12 Service Functions 12 Resetting the fixture 12 ...

Страница 3: ...ostat variable resistor or dimmer circuit even if the rheostat or dimmer channel is used solely for a 0 to 100 switch AC Voltage Switch Not all fixtures have a voltage select switch so please verify that the fixture you receive is suitable for your local pow er supply See the label on the fixture or refer to the fixture s specifi cations chart for more information A fixture s listed current rating...

Страница 4: ...re servicing or replacing fuse and be sure to replace with same fuse size and type ALWAYS secure fixture using a safety chain NEVER carry the fixture by its head Use its carrying handles DO NOT operate at ambient temperatures higher than 104 F 40 C In the event of a serious operating problem stop using the unit immediately NEVER try to repair the unit by yourself Repairs carried out by unskilled p...

Страница 5: ...AL FEATURES User selectable basic or advanced operating modes User selectable pan tilt ranges Pan 540 360 180 Tilt 270 180 90 Compact and lightweight it kept its new year s resolution LED display menu with invert Reset to factory settings option Display auto on off Pan tilt invert option Fan cooled OPTIONAL CONTROLLERS Easy Controller CA 9 DMX Quick Reference 13 Channel Mode Channel What It Does 1...

Страница 6: ...ference 5 Channel Mode Channel What It Does 1 Pan 2 Tilt 3 Dimmer Strobe 4 Color Macros 5 Reserved Figure 1 The Flurry Pin Up Picture High Power LED s Control Panel LED Readout Head Figure 2 The Rear Connections AC Power Fuse Cover 110V 220V Switch DMX In DMX Out Easy Controller CA 9 ...

Страница 7: ...32 fixtures on one serial data link without the use of a DMX optically isolated splitter may result in deterioration of the digital DMX signal The maximum recommended cable run distance is 500 meters 1640 ft The maximum recommended number of fixtures on a serial data link is 32 fixtures Data DMX Cabling To link fixtures together you ll need data cables You should use data grade cables that can car...

Страница 8: ... d like to build your own the chart below details a proper cable conversion Conductor 3 Pin Female Output 5 Pin Male Input Ground Shield Pin 1 Pin 1 DMX Data Pin 2 Pin 2 DMX Data Pin 3 Pin 3 Not Used No Connection No Connection Not Used No Connection No Connection Take It To The Next Level Setting Up DMX Control Step 1 Connect the male connector of the DMX cable to the female connector output on t...

Страница 9: ...k the Operating Adjustments section in this manual for com plete instructions for this type of setup and configuration Mounting Rigging This fixture may be mounted in any SAFE position provided there is enough room for ventilation It is important never to obstruct the fan or vents pathway Mount the fixture using a suitable C or O type clamp The clamp should be rated to hold at least 10x the fixtur...

Страница 10: ... in ascending order DOWN Scrolls through menu items and numbers in descending order ENTER Is used to select and confirm store the current selection The Control Panel LED Display shows the menu items you select from the menu map on page 11 When a menu function is selected the display will show immediately the first available option for the selected menu function To select a menu item press ENTER Pr...

Страница 11: ...Page 11 Flurry TRI Manual Rev A Copyright c 2011 Blizzard Lighting LLC Control Panel Menu Structure ...

Страница 12: ...n press ENTER to confirm TO SET THE DMX CHANNEL CONFIGURATION 1 Press the MODE ESC button until it shows or 2 Use the UP DOWN buttons to set to the desired position press ENTER to confirm TO SET THE MAXIMUM PAN ANGLE 1 Press the MODE ESC button until it shows or or 2 Use the UP DOWN buttons to set to the desired position press ENTER to confirm TO SET THE MAXIMUM TILT ANGLE 1 Press the MODE ESC but...

Страница 13: ...nits together using DMX cable Master Auto or Master Sound becomes when confirmed 3 Select slave function by using the UP DOWN keys to reach SLAv in the Master Auto menu on the slave units and they will react in the same as the Master Slave becomes when confirmed Easy Controller Mode Allows you to use the optional CA 9 Easy Controller for basic control functionality 1 Connect the CA 9 Easy Controll...

Страница 14: ...31 243 244 255 Color Macros No Function White Red Green Blue Cyan Magenta Yellow Purple Orange Chartruese Pink Brown Gold Crimson Violet Crepe Color Change Macro 1 Color Change Macro 2 11 000 255 Color Speed 12 000 007 008 023 024 039 040 055 056 071 072 087 088 104 105 117 118 135 136 151 152 167 168 183 184 199 200 215 216 231 232 247 247 255 Movement Color Macros No Function Automatic Program 1...

Страница 15: ...55 Dimmer Strobe Closed 100 0 Dimming Strobe Slow Fast Open 4 000 007 008 021 022 035 036 049 050 062 063 076 077 090 091 104 105 118 119 132 133 146 147 160 161 174 175 188 189 202 203 216 217 230 231 243 244 255 Color Macros No Function White Red Green Blue Cyan Magenta Yellow Purple Orange Chartruese Pink Brown Gold Crimson Violet Crepe Color Change Macro 1 Color Change Macro 2 5 Reserved ...

Страница 16: ...use Check AC cord and circuit for damage verify that moving parts are not restricted and that unit s ventilation is not obstructed Slow Movement Verify that 220V 110V switch is in the correct position if applicable Also check that speed channels are set appropri ately No Response to Audio Verify that the fixture is in Sound Active mode Adjust Audio Sensitivity If Applicable Fixture Not Responding ...

Страница 17: ...al 3 pin mic cables although this does not conform to the defined standard DMX is connected using a daisy chain configuration where the source connects to the input of the first device the output of the first device connects to the input of the next device and so on The standard allows for up to 32 devices on a single DMX link Each receiving device typically has a means for setting the starting ch...

Страница 18: ...atistfaction and wow factor That s what it s all about after all Returns Gasp We ve taken a lot of precautions to make sure you never even have to worry about sending a defective unit back or sending a unit in for service But like any complex piece of equipment designed and built by humans once in a while something doesn t go as planned If you find yourself with a fixture that isn t behaving like ...

Страница 19: ... LED 18x3W TRI Color 100 000 hours Edison Brand Optical Beam Angle 18 degrees Luminous Intensity 12 110 full white lux 1m Movement Range Pan 540 degrees Tilt 270 degrees Thermal Max Operating Temp 104 degrees F 40 degrees C ambient Control Protocol USITT DMX 512 DMX Channels 5 or 13 User Selectable Input 3 pin XLR Male Output 3 pin XLR Female Optional Controller CA 9 Easy Controller Military Calls...

Страница 20: ...Enjoy your product Our sincerest thanks for your purchase The team Blizzard Lighting ...

Отзывы: