Blizzard Lighting AutoBahn 8 ArtNet Скачать руководство пользователя страница 15

Page 15

AutoBahn™ 8 User Manual - Rev. A  

 

 

(c) 2014 Blizzard Lighting, LLC

This page intentionally left blank.

Содержание AutoBahn 8 ArtNet

Страница 1: ...Blizzard Lighting LLC www blizzardlighting com Waukesha WI USA Copyright c 2014 ...

Страница 2: ...3 2 Meet The AutoBahn 8 4 Main Features 4 Overview 4 3 Operating Instructions 5 Startup View 5 Renaming the Device 6 Setting the IP Address 6 Setting the Netmask 7 DMX Port Settings 7 Setting the ID 9 LCD Backlight 9 User Presets 10 Firmware Version 10 4 Appendix 11 A Quick Lesson on ArtNet 11 Keeping Your AutoBahn 8 As Good As New 12 Returns Gasp 12 Shipping Issues 12 Application Diagram 13 Dimen...

Страница 3: ... and keep the packing material for inspection Again please save the carton and all packing materials If a fixture must be returned to the factory it is important that the fixture be returned in the original factory box and packing Caution There are no user serviceable parts inside this unit Do not open the housing or attempt any repairs yourself doing so will void your manufactures warranty In the...

Страница 4: ...n be set to single zero HTP or LTP mode Each DMX input can be set to normal or backup mode DMX splitter merger functionality Manual IP address settings LCD display indicates each DMX input output status Ethernet LED status indicator Quick and easy to set user presets Overview Front Side 1 Power LED Shows unit on off status 2 Link LED Shows network connect status 3 Activity LED Flashes when data tr...

Страница 5: ...e 4 initial top tier menu status screens shown above that you ll see when you power on the unit You can scroll through them by using the UP DOWN buttons The Device Name Device ID and IP Address can all be edited later within the menu settings In the first row of the port status screen A B refers to the DMX IN A B and 1 8 refers to DMX outputs 1 8 In the second row of port status screen x means the...

Страница 6: ...u must save your changes by using the UP DOWN buttons to scroll to Enter and then push the ENTER button Setting the IP Address Enter the main menu by pressing the MENU button then use the UP DOWN buttons to highlight 2 Set IP Address Press the ENTER button Then use the UP DOWN buttons to scroll through the IP address character groups Push the ENTER button when the set of characters you d like to c...

Страница 7: ...sing the UP DOWN buttons to scroll to Enter and then push the ENTER button DMX Port settings Enter the main menu by pressing the MENU button then use the UP DOWN buttons to highlight 4 Set DMX Port Press the ENTER button Then use the UP DOWN buttons to scroll through the DMX in out port selections and push the ENTER button when highlighted 1 DMXIN Port A B DMX IN Port A B can be set as input or di...

Страница 8: ...en the Port Status is set to output the Port Mode can be set to one of the following 4 modes Zero The port sends a DMX test signal only with all channels at 0 Single The port sends the DMX values of the selected universe LTP Latest Takes Precedence Port will output the latest channel activity between 2 selected universes It compares the principal and secondary universes and sends the latest one to...

Страница 9: ...ur changes by using the UP DOWN buttons to scroll to Enter and then push the ENTER button LCD BACKLIGHT Enter the main menu by pressing the MENU button then use the UP DOWN buttons to highlight 6 Set LCD Backlight Press the ENTER button Then use the UP DOWN buttons to scroll through your choice of either 1 ON or 2 OFF ON means the LCD backlight will stay on all the time OFF means the LCD backlight...

Страница 10: ...gs restore 1 2 In 1 Backup Mode When one DMX input port is not sending a signal it will use the DMX signal from the other input 2 2 In 1 HTP Mode Compares your designated input signals and outputs the one with higher value to the network 3 2 In 1 LTP Mode Compares your designated input signals and outputs the latest to the network 4 DMX Splitter 1 4 Mode DMX IN A signal outputs to DMX out ports 1 ...

Страница 11: ...nd was developed by Wayne Howell and his company Artistic Licence Engineering Ltd USITT DMX512 is well known in the entertainment industry because it is the industry standard for controlling dimmers and automated lighting fixtures moving lights The electrical standard of DMX512 is RS485 which is as superset of RS422 which almost the same as RS232 well known as serial port on a PC Ethernet is the e...

Страница 12: ...e you never even have to worry about sending a defective unit back or sending a unit in for service But like any complex piece of equipment designed and built by humans once in a while something doesn t go as planned If you find yourself with a unit that isn t be having like a good little electronic device should you ll need to obtain a Return Authorization RA Don t worry this is easy Just send an...

Страница 13: ...l Drawings Tech Specs Weight Dimensions Length 19 inches 482 mm Height 1 75 inches 44 mm Depth 6 1 inches 155 mm Weight 5 1 lbs 2 3 kg Other Information When you step on the brakes your life is in your foot s hands Warranty 2 year limited warranty 19 inches 482mm 1 75 inches 44mm 6 1 inches 155mm ...

Страница 14: ...Page 14 AutoBahn 8 User Manual Rev A c 2014 Blizzard Lighting LLC This page intentionally left blank ...

Страница 15: ...Page 15 AutoBahn 8 User Manual Rev A c 2014 Blizzard Lighting LLC This page intentionally left blank ...

Страница 16: ...Enjoy your product Our sincerest thanks for your purchase The team Blizzard Lighting ...

Отзывы: