BLiNQ Networks Inc.
X-1200 System Installation Guide
Release 1.0
Confidential - Restricted Use and Duplication
Page
30
Issue 01 D1
Green
Green/White
Brown
Brown/White
6.
Secure and seat the conductors to the pin strip terminals by gently but firmly pressing them into
place with the terminal blocks removed in step 4. Gently pull the terminal blocks off again when
done.
7.
Once all the conductors are seated to the pin strip terminals, gently press the terminal blocks into
the pin strip terminals of your choice for storage.
8.
Repeat steps 3 through 7 through the other strain relief for the outgoing Ethernet cable running to
the X-1200 equipment.
Note:
Ensure the left-side and right-side Ethernet conductor wire colors match.
9.
Thread the incoming DC power cable from the power source through one of the strain reliefs on the
bottom of the unit.
10.
Using wire strippers, strip back the DC cable jacket about 1 in./25.4 mm to expose the two wires,
then strip the insulation about 3/8 in./9.5 mm from each wire.
11.
Insert the Ground Return (RTN) wire into DC+ of the four-position power terminal strip (the top
position), and the -48 Vdc wire into DC- of the power terminal strip (the bottom position), and
tighten each wire down to the terminal using a small slot head screwdriver.
12.
Repeat steps 9 through 11 through the other strain relief for the outgoing DC power cable running
to the X-1200 equipment.
13.
Confirm the left-side and right-side Ethernet conductor wire colors match between the left and right
Ethernet pin strip terminals.
14.
Confirm the DC power cable polarity is correct: RTN goes to DC+; -48 Vdc goes to DC-
15.
Tighten the strain reliefs onto the cables (do not over tighten).
16.
Reinstall the cover.
17.
Connect the external ground lug on the unit to a solid Earth ground. The unit must be grounded for
the arrester to work properly.