Installation Manual
BlinkCharging.com
•
(888) 998.2546
14
9. CHARGER SETTINGS
SETTING PARAMETERS
During the initial installation, the setting parameters must
be set by the manufacturer or the operating partner, or the
service partner. Changes may only be made by trained
specialist personnel.
The setting window can be accessed by following steps.
1) Touch the Tellus Power Logo
2) Provide the Password. Password will be shared to the
authorized representative
3) Select System Settings
PARAMETER
VALUE
TIME ZONE
UTC+HH:MM
PSM QUANTITY
1
POWER OUT MODE
0
OCCUPIED PLUG
1
PSM MAX VOLTAGE
1000
PSM MAX CURRENT
100
PSM MID VOLTAGE
300
PSM MID CURRENT
20
PSM MIN VOLTAGE
50
PSM MIN CURRENT
0
PMAX
30000
CCS NETWORK 1
ETH1
INSYS PLC MAC 1
00:00:00:00
TIME
2020-08-20 T20:46:25
S.NO
PARAMETERS
VALUE
REMARKS
1
NETWORK
ETH
Ethernet-DO NOT CHANGE
2
NETCFGFILE
/etc/network/interfaces
Path- DO NOT CHANGE
3
WLAN CONF
/home/guest/wpa_supplicant.conf
Path- DO NOT CHANGE
4
DEVICE IP
192.168.0.3
IP Adress of Device
5
DEVICE GATEWAY
192.168.0.1
IP Adress of Gateway
6
DEVICE NET MASK
255.255.255.0
IP Adress of Mask
7
SERVICE URL
<<Provide Portal Details>>
OCPP Server URL
8
DEVICE ID
<<Provide ID>>
Device ID
9
CHARGE POINT VENDOR
Tellus power
Charger OEM- DO NOT CHANGE
10
CHARGE POINT MODEL
DC
Charger Type- DO NOT CHANGE
11
ADPATH
./pic
Path - DO NOT CHANGE
12
QRCODE NAME
NA
13
LANG
en
Path - DO NOT CHANGE
14
MODE
offline/record/upload/debug
Path - DO NOT CHANGE
15
CHARGING PIC
/img/charging_tata.jpg
Path - DO NOT CHANGE
16
IDLE PIC
/img/standby.jpg
Path - DO NOT CHANGE