Via Montefeltro, 6 – 20156 Milano (MI) – Italy
- 30 -
Tel. +39 (02) 3088583 – Fax +39 (02) 33406697
www.blinkmarine.com
–
PKP-2200-SI_CANopenUM_REV1.0
•
Number of mapped objects: 1;
•
Set Indicator LED brightness: Object 2003h, Sub index 01h, Length 08h.
42.
Object 1603h: Receive PDO mapping Parameter 3
Describes the mapping of backlight brightness PDO Message.
Identifier
615h (600h + current CAN ID)
Byte 0
40h
Read Device Register
Byte 1
03h
CAN Object 1603h
Byte 2
16h
Byte 3
00h
Number of mapped objects
01h
PDO Mapping Entry 1
Byte 4,7
00h
Not used
Examples:
Direction
Identifier
Format
Message
Data
To Keypad
615
Std
40 03 16 00 00 00 00 00
Keypad reply
595
Std
4F 03 16 00 01 00 00 00
1
To Keypad
615
Std
40 03 16 01 00 00 00 00
Keypad reply
595
Std
43 03 16 01 08 02 03 20
2003 02 08
Receive PDO mapping Parameter 3:
•
Number of mapped objects: 1;
•
Set backlight brightness: Object 2003h, Sub index 02h, Length 08h.