6

 

 

 

   

7

Charge on.

Charge on.

Model HQ

Mechanical

Charging Cable Length

18 ft (5.5 m), straight cable

Ingress Protection

Type 3R

Mounting Type

Wall-Mount

Cooling

Natural cooling

Dimension (W x H x D)

13.8 x 15.7 x 5.0 inch (350 x 400 x 126 mm), excluding 

charging cable, support bracket and cable holder

Net Weight

15.4 lb (7 kg)

Regulation

UL

Charging Interface

SAE J1772 compliant charging plug

Accessibility

such that the height of the storage means for the coupling de-

vice is located between 24 inches (600 mm) and 4 feet (1.2 m) 

from grade per NEC Article 625.

3 Installation

3.1 Before Installation

3.1.1  Safety Check

 

CAUTION:

 DISCONNECT ELECTRICAL POWER PRIOR TO INSTALLING THE BLINK CHARGER.  FAILURE 

TO DO SO MAY CAUSE PHYSICAL INJURY OR DAMAGE TO THE ELECTRICAL SYSTEM AND BLINK 

CHARGING UNIT.

The Blink Charger should be installed only by a licensed contractor, and/or a licensed electrician in accordance 

with all applicable state, local and national electrical codes and standards.
Before installing the Blink Charger, review this manual carefully and consult with a licensed contractor, licensed 

electrician and trained installation expert to ensure compliance with local building practices, climate conditions, 

safety standards, and state and local codes.
Use appropriate protection when connecting to the main power distribution cable. Use tools as outlined in the 

section “Tools Required for Installation”.

3.1.2  GROUNDING INSTRUCTIONS

This product must be connected to a grounded, metal, permanent wiring system; or an equipment grounding 

conductor must be run with the circuit conductors and connected to the equipment grounding terminal or lead on 

the product. 

3.2 Tools & Parts Required for Installation

Table 3-2.  Tools & Parts Required for Installation

Tool

Size

Supplier

EVSE Mounting Bracket

N/A

Blink

Torx Bolts (3 each) - used to secure the 

EVSE to the mounting bracket

T30

Blink

Cable hanger bracket

N/A

Blink

Conduit – used for power wire

1”

Commercially available

Screws (2 each) – used to secure the main 

body mounting bracket on the wall

#10 x 2.5” Wood Screws, 

Countersunk Phillips Head

Commercially available

Torx Driver

T30

Commercially available

Torque Wrench

N/A

Commercially available

Screws, wood (if required)

No. 8

Commercially available

Bolts (for masonry)

1/4”, expansion

Commercially available

Wire, Copper

No. 8 AWG, 75°C or 90°C

Commercially available

Содержание HQ Charger

Страница 1: ...Instruction Manual Blink HQ Charger Charge on a CarCharging Company ...

Страница 2: ... 14 4 3 Charging an Electric Vehicle EV 15 4 3 1 Interrupt Charging 18 4 3 2 Auto Restart 18 4 3 3 Power Outage Recovery 19 4 4 Troubleshooting 19 4 5 General Care 20 Federal Communications Commission FCC Regulatory Statements and Notices This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to...

Страница 3: ...nk is not responsible for physical injury damage to property or equipment caused by the installation of this device This document provides instructions for the Blink Charger and should not be used for any other product Before installation or use of this product review this manual carefully and consult with a licensed contractor licensed electrician or trained installation expert to make sure of co...

Страница 4: ... owner s manual to determine ventilation requirements WARNING Do not use extender cables to increase the length of the charging cable Maximum length is limited to 25 feet by the National Fire Protection Agency WARNING To reduce the risk of fire replace only with same type and ratings of fuse WARNING To reduce the risk of fire connect only to a circuit provided with 40 amperes maximum branch circui...

Страница 5: ...ID per UL 2231 Upstream Breaker 2 pole 40 A breaker on dedicated circuit non GFCI type Plug Out Protection Power output is terminated upon detection of charging connector plug out Electrical Protection Over Current Short Circuit Over Voltage Under Voltage Ground Fault Surge Protection Over temperature User Interface Control Status Indicators Standby green Charging flashing green Fault red Warn ing...

Страница 6: ...ntractor licensed electrician and trained installation expert to ensure compliance with local building practices climate conditions safety standards and state and local codes Use appropriate protection when connecting to the main power distribution cable Use tools as outlined in the section Tools Required for Installation 3 1 2 GROUNDING INSTRUCTIONS This product must be connected to a grounded me...

Страница 7: ...he mounting bracket and the cable hanger Note Follow applicable accessibility requirements for the mounting position The unit shall be mounted at a sufficient height from grade such that the height of the storage means for the coupling device is located between 24 inches 600 mm and 4 feet 1 2 m from grade per NEC Article 625 Masonry Walls Sheet Rock and Wood Stud Walls Figure 3 1 Mounting Bracket ...

Страница 8: ... Wiring 4 Align the screw holes of the mounting bracket with the Blink charger holes Figure 3 4 Blink Charger and Mounting Bracket 5 Install and secure with three screws to the mounting bracket Figure 3 5 Mounting Bracket Screws PE L2 L1 ...

Страница 9: ... Status Indicators Table 4 1 Charging Status Indicators FRONT PANEL LED BEHAVIOR DESCRIPTION DEFINITION Not illuminated Charger is powered OFF Use the Power ON OFF switch to power ON the Charger Green Charger is powered ON and ready for charging Flashing green Charging in process Red Charger malfunction Stop using immediately Flashing red Charger is recovering from a minor fault such as OVP UVP OT...

Страница 10: ...ay Timer is not enabled 2HR 4HR 6HR 8HR Charger is ready and the delay timer can be set 2HR 4HR 6HR 8HR 2HR LED solid ON Delay Timer is set to 2 hours 2HR 4HR 6HR 8HR 2HR and 4HR LEDs solid ON Delay Timer is set to 4 hours 2HR 4HR 6HR 8HR 2HR 4HR and 6HR LEDs solid ON Delay Timer is set to 6 hours 2HR 4HR 6HR 8HR 2HR 4HR 6HR and 8HR LEDs solid ON Delay Timer is set to 8 hours 2HR 4HR 6HR 8HR Delay...

Страница 11: ...elay Timer 5 Disconnect the charging plug from the EV or press the STOP button to stop charging before the charge is complete 6 Reconnect the charging plug to start charging again Refer to Step 2 of this Section Figure 4 5 Press the Stop Button 7 When charging is complete disconnect the charging plug from the EV and place it in the charger holster Figure 4 6 Remove the Charging Plug from the EV Fi...

Страница 12: ...avoid impacting the utility grid when multiple chargers are in the same area attempting to resume charging simultaneously SITUATION ACTION Status indicator does not turn on 1 Make sure the power input is connected correctly 2 Turn the Blink HQ charger power OFF then back ON 3 If the problem persists contact Customer Support Status indicator does not blink when the charger is connected to the EV 1 ...

Страница 13: ...ssing the STOP button 4 Unplug the charging connector 5 Wait until the status indicator turns solid green 6 Press Delay timer button to set delay timer 7 Connect charger to the EV 8 Delay timer will start to count down 4 5 General Care The exterior of the Charger is designed to be rainproof To ensure proper maintenance of the charger follow these guidelines Despite the water resistance of the encl...