I. Specifications
Instruccions DETECT-E
Detect – S is a new product adopting a microwave sensor with high frequency electromagnetic waves (5.8Ghz), gathering automatism,
convenience, safety and energy saving in a smaller size. As soon as someone enters its detection field, Detect-S starts up almost instantly
identifying day and night cycles. Detect–S can detect trough doors, glass and thin walls.
Power Sourcing
Frequency
Detection Range
Detection distance
Ambient Light
Time-Delay
Load
Working temperature
Humidity
Power Consumption
Intalling height
Detection Motion speed
All responsibilities for defects or damages are hereby rejected, if caused by: Incorrect assembling
of the product; incorrect supply, use of lamps not suitable for this product; external agents. BLI_01.1_2017
All responsibilities for defects or damages are hereby rejected, if caused by: Incorrect assembling
of the product; incorrect supply, use of lamps not suitable for this product; external agents. BLI_01.1_2017
220-240 V/AC
50Hz
180º
5m - 15m (<24)
-20~+40
<93%RH
aprox.0.9W
0.6-1.5m/s
Min. 10seg. 3seg.
3-2000LUX (aj.)
Max. 12min. 2min.
300W
Max. 1200W
1-1,8m
±
±
Identify day and night automatically. Can adjust ambient light according to your desire: when turn to SUN (max), it will work in the daytime
and at night. When turn to MOON (min), it will only work under less than 3LUX circumstance. As for Adjustment, please refer to testing way.
Time-delay is added continually: when it receives the second induction signal after the first inductor, it will compute time once more on
the rest of the first time-delay basic (Set time).
Detect–S sensitivity can be set accordingly to your needs. If low sensitivity is needed, set the dial to 5 meters, otherwise turn the dial
to 15 meters.
Time-delay adjustment: it can be set according to your desire. The minimum is 10±3 sec; the maximum is 12±2min.
II. Function
NOTE:
when testing in daylight, please turn LUX knob to SUN position, otherwise
the sensor lamp could not work!
IV. Test
Set the LUX knob clockwise until the SUN symbol is reached, then turn SENS knob clockwise until it reaches the + symbol
and turn the TIME knob anti-clockwise until the 10s is reached.
Connection Sketch (Figure 4):
Next switch on the power, if you followed the guide to this point it should start
working, the light will turn on immediately turning off after 10s +- 3 sec.
Should it receive a second signal amidst the first cycle, the timer will add up, meaning
that the overall timer the bulb stays on will increase.
Turn LUX knob anti-clockwise on the minimum (3). If the ambient light is less than 3LUX
(darkness), the inductor load could work when it receives induction signal.
III. Installation
Turn off the power
Open Detect –S faceplate and adjust the Time and Lux knob.
Loosen the screws on the connection terminal and connect the power cables as shown in the diagram (figure 4).
Detect – S can be installed in circular or square sockets. For round sockets put it and spray bolt on both sides (Figure 2).
For square sockets fix the screws through the mounting hole. (figure 3).
Put back the faceplate, and switch ON the power.
Reg nº 402030
www.blink.com.pt
Reg nº 402030
www.blink.com.pt
NOTA:
The installation must be executed by a qualified professional, whom must follow these instructions rigorously.
Read these instructions carefully before using this product.
The High – Frequency output is lower than 0.2MW