Via Montefeltro, 6 – 20156 Milano (MI) – Italy
- 14 -
Tel. +39 (02) 3088583 – Fax +39 (02) 33406697
www.blinkmarine.com
–
PKP-2400-LI_CANOpen_UM_REV1.1
g)
Set Boot-up service: 13h
Identifier
600h + current CAN ID
Default 615h
Byte 0
23h
Set Device Register
Byte 1
00h
CAN Object 6500h
Byte 2
65h
Byte 3
01h
Sub index
Byte 4
13h
Command: Set Boot-up service
Byte 5
XXh
00h: Not active
01h: Active
Byte 6,7
00h
Not used
Example:
Direction
Identifier Format Message
Data
To Keypad
615
Std
23 00 65 01 13 00 00 00 Set Boot-up service
not active
Keypad reply
595
Std
60 00 65 01 00 00 00 00
h)
Set CANopen node ID: 70h
Identifier
600h + current CAN ID
Default 615h
Byte 0
23h
Set Device Register
Byte 1
00h
CAN Object 6500h
Byte 2
65h
Byte 3
01h
Sub index
Byte 4
70h
Command: Set CAN ID
Byte 5
XXh
New ID (00h-7Fh), default 15h
Byte 6,7
00h
Not used
Example:
Direction
Identifier
Format Message
Data
To Keypad
615
Std
23 00 65 01 70 18 00 00 New Id = 18
Keypad reply
595
Std
60 00 65 01 00 00 00 00
Keypad reply
718
Std
00
Boot-up message
with the new ID set
The first reply is with the old node ID.
i)
Set default startup LED light level: 7Ch
Identifier
600h + current CAN ID
Default 615h
Byte 0
23h
Set Device Register
Byte 1
00h
CAN Object 6500h
Byte 2
65h
Byte 3
01h
Sub index
Byte 4
7Ch
Command: Set startup LED level
Byte 5
XXh
0-3Fh
à
min-100%
Byte 6,7
00h
Not used
Example:
Direction
Identifier Format Data
To Keypad
615
Std
23 00 65 01 7C 3F 00 00 Set startup LED level
at 100%
Keypad reply
595
Std
60 00 65 01 00 00 00 00