RLINK User Manual
8/14
RLINK
Part 3 Configuration
RLINK has been configured at the factory and generally does not require additional
configuration. If you need to modify the parameters, you can customize the configuration
according to the instructions below.
3.1 Enter Configuration Mode
Connect RLINK(the ground end) to the computer via a data cable at first, make sure the
your serial assistant can communicate with RLINK, press and hold the RLINK CONFIG
key with a thimble or other sharp object. The RLINK will enter configuration mode when
the serial assistant pops up the NO CARRIER 0K prompt and then release CONFIG key.
Figure 3.1 Enter configuration mode
After entering configuration mode, the configuration can be completed by sending the
relevant parameters via the serial assistant (all with OK after successful configuration).
Noting that every configuration command needs to be followed by a carriage return.
3.2 Common Commands Reference
➢
Common commands
ATS101: Operator Mode
(
0 – Master
;
1 –Repeater
;
2 – Slave
)
ATS133: Network Type
(
0 – Point to Mutlipoint
;
1 – Point to Point
)
ATS102: Serial Baud Rate
(
0 - 230400
;
1 - 115200
;
2 - 57600
;
3 - 38400
;
4 - 28800
;
5 - 19200
;
6 - 14400
;
7 - 9600
;
8 - 7200
;
9 - 4800
;
10 - 3600
;
11 - 2400
;
12 - 1200
;
13 – 600
;
14 - 300
)
ATS103: Wireless Link Rate
(
0 - 172800
;
1 - 230400
;
2 - 276480
;
3 - 57600
;
4 - 115200
)
ATS108: Output Power
(
20 - 100
;
21 - 125
;
22 - 160
;
23 - 200
;
24 - 250
;
25 - 320
;
26 - 400
;
27 - 500
;
28 - 630
;
29 - 900
;
30 -1000
)