If your cooling water is too hot to cool to your desired wort outlet temperature, you will need to use an 
immersion chiller in an ice-bath in conjunction with your Therminator

TM

 chiller to lower the cooling water 

temperature the additional degrees.  Since the Therminator

TM

 chiller will remove the vast majority of the 

heat in a very short period of time, much less ice will be consumed.  A 6 m (20 ft) length of 5/8” copper 
tube immersed in a ca. 20 L (5 gal) pail of ice and water will usually be sufficient.  Pre-chilling the cooling 
water, instead of post-chilling the wort in another exchanger, reduces the possibility of contamination 
since the cooling water chiller doesn’t need to be sanitized. 

 
Therminator Accessories:

 are available through your Blichmann Engineering retailer.  Designed 

with the highest quality and attention to detail to give you the best beer possible, with the least hassle. 
 

   

 

 
 
 

 
 
 
 
 
 
Troubleshooting: 

 
Not reaching desired wort temperature:  

 

Use graph on page 6 to estimate cooling capacity with the cooling water temperature and flow rate 
in your brewery.  Water supplies change temperature depending on the season, and flow can 
change with varying system water usage. 

 

Be sure exchanger is installed at the low point in the system so it is completely full of wort.   

 

Be sure unit is operated on its side so all the air is purged from the unit. 

 

Unit is fouled from water salts – see “Periodic maintenance” section above 

Not reaching desired wort flow: 

 

Use graph on page 6 to estimate flow capacity with the cooling water temperature and flow rate in 
your brewery.  Water supplies change temperature depending on the season, and flow can change 
with varying system water usage. 

 

For gravity drain systems, you may not be able to meet the maximum flow needed based on 
available elevation of the brew pot and restriction of the brew pot drain and hoses.  The exchanger 
itself adds a negligible restriction (about 0.1 PSI or .6” of water column) 

 

Hose diameter too small causing excessive restriction - use a larger diameter hose. 

 

Check for blocked or plugged brew pot suction, hose, flow control valve, or exchanger inlet.  If 
plugged, it is recommended that you install a stainless scouring pad or suction screen to the 
suction (inlet) of your brew pot to ensure particulate matter remains in the brew pot.  This will also 
enhance the flavor and clarity of your finished beer by removing trub from the finished wort.   

Sanitation (contamination) problems: 

 

Thoroughly read “Cleaning & Sanitation” section above specifically: 

 

Ensure unit is cleaned with hot water, PBW, and sanitizer IMMEDIATELY after each use 

Back-flush hose assembly 
(057.029.IBF) 

 

18” long ½” ID hose with Garden Hose 
thread and ½” QuickConnector

TM

 on 

the ends. 

 

Makes cleaning your Therminator

TM

 

hassle free! 

QuickConnector

TM

 

 

Stainless barb available for 1/2” or 
3/8” ID hose.  Includes silicone o-ring 

and nickel plated brass nut (does not 

touch liquid).  Tightens by hand! 

 
Makes connecting your Therminator

TM

 

a snap! 

Therminator

TM  

Accessory Kit 

 
Includes back-flush hose and a pair of  

QuickConnector

TM

 fittings (your choice 

of 1/2” or 3/8” barb) 

 
Everything you need for your 
Therminator

TM

 

Содержание Therminator 057.029.1

Страница 1: ...on Sections labeled Caution can lead to equipment damage or unsatisfactory performance of the equipment Please read these sections thoroughly and if you have any questions contact your retailer or Blichmann Engineering before use Assembly Threaded fittings The TherminatorTM utilizes NPT National Pipe Taper male threads for the wort side of the exchanger top fittings on the back and front of the ex...

Страница 2: ...per braze material Powdered Brewery Wash is just as effective and MUCH safer to use Any other non chlorine sanitizer is acceptable to use IodophorTM or StarSanTM see warning below both work very well and do not require rinsing Prior to the first use soak the unit in PBW Powdered Brewery Wash with the fittings facing up so all air is purged from the exchanger and all surfaces get wetted Rocking the...

Страница 3: ...tallation Operation For the exchanger to perform properly it is critical that all surfaces of the exchanger be continuously flooded with cooling water and wort If air is trapped in the unit not only will the exchanger performance drastically drop but also you will be oxidizing your wort It is also permissible to operate the unit with the fittings facing vertically but the wort inlet should be faci...

Страница 4: ...ng water on to the maximum flow rate which will purge all air from the water side of the exchanger Slowly increase the hot wort flow rate until you reach the desired outlet temperature If using the ThruMometerTM in line thermometer and you never see a change in color on the thermometer elements carefully touch the side of the ThruMometerTM and determine if the temperature is above 88oF or below 58...

Страница 5: ...Use graph on page 6 to estimate flow capacity with the cooling water temperature and flow rate in your brewery Water supplies change temperature depending on the season and flow can change with varying system water usage For gravity drain systems you may not be able to meet the maximum flow needed based on available elevation of the brew pot and restriction of the brew pot drain and hoses The exch...

Страница 6: ...arden hose as the cooling media Wort specific gravities above 1 040 will perform slightly lower than the graph Specific gravities below 1 040 will perform slightly better than the graph Note that small changes in inlet cooling water temperature and flow can have a large impact on the wort outlet temperature and flow Therminator Performance Data 1 040 S G 68 F Wort Outlet Temp 50 52 54 56 58 60 62 ...

Страница 7: ...e to use TeflonTM thread sealing tape where recommended Blichmann Engineering is not responsible for incidental or consequential damages arising from use or misuse of this product This product is intended for home use only No warranty or guarantee of suitability express or implied is given for commercial use of this product Blichmann Engineering must be notified within 7 days of the ship date of a...

Отзывы: