background image

Go to "Settings" (icon in the upper right corner of the screen), go to the "Gate 
settings" section and select the appropriate option in the "Gate type" field. 
Then, depending on your control panel, select the function of the second 
(auxiliary) output. After saving the settings, go to the main panel by clicking 
the arrow in the upper left corner. Test the controller work of by clicking the 
gate / door icon - the control panel should force the motor to move.

In the "Gate settings" section, in the field "Address (URL) of the MJPEG stream" 
you can enter the URL stream of the camera IP which supervise the motor. 

In case you need to make changes in the advanced controller settings, 
click on "Show advanced" button. Will appear additional options.

In the "Gate output type" field, the output behavior can be changed between 
the normally open output (NO - when the output is not shorten) or normally 
closed (NC - in other words the contact pair is shorten, opens when the user 
presses the control button). It is also possible to adjust the duration of the 
impulse in the output - between 0.1 sec. to 15 seconds - after a single press of 
the control button. The option "Outputs swap" allows you to correct the order 
of pairs of wires without switching them again, for example when the gate 
control wire has been connected to the O2 output instead of under O1.

Go to the main panel by clicking the arrow in the upper left corner. If the 
motor position sensor circuit has been connected, test the gate work - click on 
the gate / door icon, the control panel should force the motor to move. Note 
the blue border around the icon. If the motor is in an intermediate position, 
the icon's border will be half blue and half gray. The limit position in the 
"Open" state is indicated by a gray border and in the "Closed" state by a blue 
border.

If you need to change the advanced settings of the controller associated with 
the inputs, return to the controller settings, go to the "Gate settings" section 
and then click the "Show advanced" button. Will appear additional options. If 
despite the correct wiring, the controller can not detect the motors position, 
is possible to change the detection method of the limit switches connected to 
IN1 / IN2 inputs. If the state of the motor position is detected inversely, i.e. the 
motor is physically in the closed position and the visualization indicates that it 
is open, it means that the pairs of wires in the IN1 / IN2 inputs have been 
changed, so the option should be changed in the field "Inputs swap (IN1, IN2)" 
to "Enabled".

Download the 

free wBox application

. If you have an Android mobile device, 

you will find the application in the Play Store. For iOS devices the application is 
in the App Store. 

By using your mobile phone or tablet, connect it to the device wireless 
network. To do this, enter to your smartphone or tablet settings, then go to 
setting of the WiFi network and find the network name "gateBoxPro-
-xxxxxxxxxx” where xxxxxxxxxx is the serial number of the device. Connect to 
this network.

Open the wBox application. A device will appear at the top of the screen. To 
add it to the application, click on "+" on the right side of the name. To pre- 
configure the controller, click on the default device name.

2

FIRST START

You can also set the configuration using the web browser 
of your phone / tablet. After connecting to the wireless 
network of the controller, turn on the browser and go 
website www.blebox.eu

The meaning states of the limits detected in the IN1 / IN2 
inputs (it mean which of the IN1 or IN2 inputs indicates the 
closed position and which the open position) can be 
changed in the controller settings menu in the option 
"Replace inputs".

The limit state is detected if there is a current flowing between the IN1 
and COM connectors and between the IN2 and COM does not. 
Analogously, the opposite state will be detected when there is no 
current flowing between the IN1 and COM connectors, and will flow 
between the IN2 and COM connectors. Any other configuration of the 
current flow is equivalent to the motor position beyond the limit 
positions. Inputs IN1, IN2 and COM have no specific polarity, they are 
galvanically isolated from the rest of the controller. The range of 
allowable voltages on the individual input pairs is 12 - 24V AC / DC.

Information advanced for installers regarding inputs, 
when is connected to a motor control panel for which is 
not available diagram.

Read the diagram and then proceed to install the controller. Pay particular 
attention to the designation of the controller connectors. Start by connecting 
the + 12V / + 24V power wires (red or black with a white dotted line) and GND 
(black).

Paying attention to the polarity, connect the inputs controlling the engine 
control panel. Depending on the control panel, will be necessary to connect 
one or two inputs. The controller output O1 is destined for control in the open 
/ stop / close mode. The O2 output is an auxiliary output, applicable in the 
control panel requiring a connection stop circuit when the motor works, or 
may be used as an additional function, e.g. "wicket" if the control panel is 
equipped with this functionality.

After making sure that the device is connected in accordance with the 
diagram and that there are no metal components near the controller which 
may accidentally cause short-circuit, start the device by turning on the power 
(turning on the mains fuse or connecting the power cord to the power outlet).

If the motor has electromechanical limits switch, it is possible to receive 
feedback from the controller, indicating the position of the motor in the 
positions "Open" (intermediate position) "Closed". To do this, connect input 
IN1 of the controller to the connector of the motor control panel which 
indicates the closed position of the motor (usually FTC, SWC, FC), the IN2 input 
should be connected to the connector indicating the open position of the 
motor (usually FCO, SWO, FA), while the common COM input of the controller 
should be connected to the corresponding common signaling of the motor 
control panel . The connection polarity of the controller inputs is not 
significant.

It is necessary to connect the right pin of the given output 
(O1 / O2) so that it has a higher potential than the left pin. 
In case of an inverted connection, due to the internal 
construction, it will connect the output which may cause 
the movement of the motor even without control it. In this 
situation, it is necessary to reverse the pair of wires 
connected inside output.

Pay attention to the maximum output current 
capacity - the control current cannot exceed 20mA 
per output. Overloading the output will cause 
irreparable damage to the controller.

Information advanced for installers in relation to the 
output polarity, when is connected to engines control 
panels for which the scheme is not available.

3

ACCESS POINT AND WIFI NETWORK SETTINGS

Once you turn on the controller for the first time, you can proceed to its 
further configuration. Being connected to the WiFi network emitted by the 
device, in the control panel of the wBox application select the device, then go 
to “Settings” (icon at the top-right corner of the screen).

Содержание GateBoxPro

Страница 1: ... FC close possition input STOP N C external button common for external buttons P P N O external button common for inputs control with μWiFi technology from any place in the World Apply the safety systems described in the PN EN 13241 standard defining the safety requirements and operational requirements for gates and barriers SAFETY RULES Connect only in accordance with the diagram presented in the...

Страница 2: ...IN1 IN2 inputs it mean which of the IN1 or IN2 inputs indicates the closed position and which the open position can be changed in the controller settings menu in the option Replace inputs The limit state is detected if there is a current flowing between the IN1 and COM connectors and between the IN2 and COM does not Analogously the opposite state will be detected when there is no current flowing b...

Страница 3: ...work or from anywhere in the World To do this in the Connect settings section select a network name from the list and press Connect If is required enter the WiFi network password During the connection of the controller to your home network the phone tablet may disconnected from the network In this case you will need to reconnect your phone tablet to the controller network Please remember that in o...

Страница 4: ...RECOMMENDED PROTECTION FOR GATES SLIDE GATE GARAGE DOOR maximum 20 cm maximum 20 cm minimum 50 cm maximum 20 cm SWING GATE maximum 20 cm maximum 20 cm maximum 20 cm minimum 25 cm minimum 50 cm ...

Страница 5: ...F REEL SWITCH FOR SECTIONAL DOORS side view magnets reel switch sensor reel switch sensor magnets magnets reel switch sensor magnets magnets reel switch sensor reel switch sensor front view top view CLOSED GATE OPEN GATE ...

Страница 6: ... switch sensor magnets reel switch sensor CLOSED GATE CLOSED GATE OPEN GATE OPEN GATE magnets reel switch sensor magnet magnet side view front view top view CONECTION EXAMPLE OF REEL SWITCH FOR SLIDING GATE ...

Отзывы: