Blaze 40E Скачать руководство пользователя страница 19

ECO

 

BLAZE

 

60E

 

(600V)

 

BLAZE

 

60E

 

(600V)

 

CONTROL

 

PANEL

 

BREAKOUT

 

REV

 

1

 

 

ITEM#

 

PART

 

#

 

DESCRIPTION

 

QUANTITY

 

1

 

C50127

 

FAN

 

MOUNT

 

1

 

2

 

C50128

 

FAN

 

POST

 

4

 

3

 

C50235

 

TRANSFORMER

 

1

 

4

 

C50257

 

CONTACTOR

   

1

 

5

 

C50131

 

BLACK

 

CAM

 

LOCK

1

6

 

C50132

 

RED

 

CAM

 

LOCK

 

1

 

7

 

C50133

 

BLUE

 

CAM

 

LOCK

1

8

 

C50134

 

GREEN

 

CAM

 

LOCK

 

1

 

9

 

C50239

     

FUSE

 

HOLDER

                                            

1

 

10

 

C50241

     

60A

 

FUSE

         

3

11

 

C50135

 

FUSE

 

HOLDER

 

1

 

12

 

C50137

 

30A

 

FUSE

         

3

13

 

C50240

 

FUSE

 

HOLDER

 

1

 

Содержание 40E

Страница 1: ...NUAL IMPORTANT INSTRUCTIONS READ AND UNDERSTAND THIS MANUAL BEFORE ASSEM BLING STARTING OR SERVICING THE HEATER IMPROPER USE OF HEATER CAN CAUSE SERIOUS INJURY KEEP THIS MANUAL FOR FUTURE REFERENCE SAVE THESE INSTRUCTIONS FOR PROFESSIONAL USE ONLY ...

Страница 2: ...NDERSTAND AND FOLLOW THE INSTRUCTIONS SHOULD USE OR SERVICE THIS HEATER IF YOU NEED ASSISTANCE OR HEATER INFORMATION SUCH AS AN INSTRUCTIONS MANUAL LABEL ETC CONTACT THE MANUFACTURER WARNING FIRE BURN INHALATION AND EXPLOSION HAZARD KEEP SOLID COMBUSTIBLES SUCH AS BUILDING MATERIALS PAPER OR CARDBOARD A SAFE DISTANCE AWAY FROM THE HEATER AS RECOMMENDED BY THE INSTRUCTIONS NEVER USE THE HEATER IN S...

Страница 3: ...D TURN OFF POWER TO HEATER CIRCUIT AT MAIN DISCONNECT PANEL DO NOT INSERT OR ALLOW FOREIGN OBJECTS TO ENTER ANY VENTILATION OR EXHAUST OPENING AS THIS MAY CAUSE AN ELECTRIC SHOCK OR FIRE OR DAMAGE THE HEATER USE THIS HEATER ONLY AS DESCRIBED IN THIS MANUAL ANY OTHER USE NOT RECOMMENDED BY THE MANUFACTURER MAY CAUSE FIRE ELECTRIC SHOCK OR INJURY TO PERSONS PREVENT A POSSIBLE FIRE DO NOT BLOCK AIR I...

Страница 4: ...ostat option is available Safety NOTE Wiring procedures and connections shall be in accordance with the national and local codes having jurisdiction Always verify that you have proper voltage supply 240V 480V or 600V depending on the which version you have purchased It is important to check the wiring connections inside the heater before plugging in the Cam Locks Use a meter to measure volt supply...

Страница 5: ...and curtains at least 15 feet 4 6 m from the front of the heater and keep them away from the sides and rear The discharge temperature of these units may reach very high temperatures Maintain minimum distance from combustible materials as follows MINIMUM CLEARANCES Top to Combustibles 6 152 mm Sides to Combustibles 6 152 mm Bottom to Combustibles 6 152 mm Discharge End to Combustibles 15 4 6 m ...

Страница 6: ... Be sure to check the fan assembly and ensure the motor and blade are operating properly 4 Compressed air may be used to keep components free of dust and dirt build up WARNING Any non routine maintenance must be performed by an authorized service representative Pre Start Checklist 1 Heater must be level and lockable wheels must be in the locked position 2 Make sure fan switch and heat selection sw...

Страница 7: ...op cover to heater using the same hardware 3 Connect Flanged Cam locks to female cam locks colour coded Connect cam locks as follows RED L1 BLACK L2 BLUE L3 Ground G 3PHASEUNITCONNECTION 4 Turn on power supply 5 Determine Bypass or Remote Stat if remote set desired temperature 6 Turn Heat on off switch to the ON position The blower will start and heater elements will start to heat up 7 Turn on hea...

Страница 8: ...flow TEMPERATURE SETTINGS HEAT SETTINGBTU Hr CFM 60kW 205 000 4 500 40kW 136 500 4 500 20kW 68 250 4 500 FAN ONLY 04 500 SHUTDOWN 1 Move heat ON OFF control setting to the OFF position 2 When cooling fan shuts down you may shut off power source 3 Shut off power source 4 Disconnect all power sources 5 Store heater ...

Страница 9: ... 480V or 600V MAXIMUM INPUT KW 136 500 BTU Blaze 40E 205 000 BTU Blaze 60E 240V 480V 600V AMP DRAW 60KW 144 72AMPS 58 AMPS 40KW 96 48AMPS 39 AMPS 20KW 48 24AMPS 19 5 AMPS INLETSIZE OUTLETSIZE Designedfor20 Dia Ducting DIMENSIONS HXLXW IN WEIGHT 12 Dia 12 or 16 Dia 51 5 X 22 X 35 5 300 LBS ...

Страница 10: ...10 ...

Страница 11: ...11 ...

Страница 12: ...E PANEL LEFT 1 3 C50117 SIDE PANEL RIGHT 1 4 C50118 DOOR PANEL 1 5 C50119 ACCESS PANEL 1 6 C50120 ELECTRICAL PANEL 1 7 C50121 PANEL 1 8 C50122 ELECTRICAL PANEL CONTROLS 1 9 C50123 DEFLECTOR RIGHT 1 10 C50124 DEFLECTOR LEFT 1 11 C50125 TOP PANEL 1 12 C50126 RETURN PANEL SUPPLY PANEL 1 13 C50127 FAN MOUNT 1 14 C50128 FAN POST 4 ...

Страница 13: ... BLAZE 60E 240V 480V 15 C40029 FAN MOTOR E 1 16 C40030 INLET CONE FOR FAN MOTOR E 1 OPTIONAL PARTS C40051 FAN MOTOR R 1 C40052 INLET CONE FOR FAN MOTOR R 1 C50159 12 SUPPLY PANEL 1 C50160 16 SUPPLY PANEL 1 ...

Страница 14: ...FAN MOUNT 1 2 C50128 FAN POST 4 3 C50129 ROTARY SWITCH 1 4 C50130 TRANSFORMER 1 5 C50131 BLACK CAM LOCK 1 6 C50132 RED CAM LOCK 1 7 C50133 BLUE CAM LOCK 1 8 C50134 GREEN CAM LOCK 1 9 C50135 FUSE HOLDER 1 10 C50136 FUSE HOLDER 1 11 C50162 FUSE HOLDER 1 12 C50137 30A FUSE 3 13 C50138 60A FUSE 3 14 C50163 100A FUSE 3 ...

Страница 15: ... 3 31 C50155 AIR SWITCH 1 32 C40033 TEMPERATURE CONTROLLER 1 33 C50156 THERMOCOUPLE ASSEMBLY 1 34 C50167 ELEMENT 1 35 C50168 CASTER 4 36 C40029 FAN MOTOR E 1 37 C40030 INLET CONE FOR FAN MOTOR E 1 38 C90055 CAPACITOR FOR FAN MOTOR E 1 39 C50124 DEFLECTOR LEFT 1 40 C90041 HIGH LIMIT SWITCH 1 41 C70064 SELECTOR SWITCH 1 42 C50299 HINGE 2 43 C70087 GRAB HANDLE 1 44 C50298 1 4 TURN LATCH 1 45 C70072 F...

Страница 16: ...40 480V DECAL KIT C50317 SERIAL NUMBER VARIABLE DATA C50302 CAMPO LOGO C50303 CAUTION SHOCK RISK C50304 CAUTION BURN FIRE HAZ C50305 CAUTION CAM LOCKS C50306 DANGER MOVING PARTS C50307 DANGER HAZ VOLTAGE C50308 CAUTION AIR FLOW BLOCK C50309 MUST BE GROUNDED C50318 BLAZE 60E C50311 BUTTONS ...

Страница 17: ...EL LEFT 1 3 C50117 SIDE PANEL RIGHT 1 4 C50118 DOOR PANEL 1 5 C50119 ACCESS PANEL 1 6 C50120 ELECTRICAL PANEL 1 7 C50121 PANEL 1 8 C50122 ELECTRICAL PANEL CONTROLS 1 9 C50123 DEFLECTOR RIGHT 1 10 C50124 DEFLECTOR LEFT 1 11 C50125 TOP PANEL 1 12 C50126 RETURN PANEL SUPPLY PANEL 1 13 C50127 FAN MOUNT 1 14 C50128 FAN POST 4 ...

Страница 18: ...CO BLAZE 60E 600V 15 C40029 FAN MOTOR E 1 16 C40030 INLET CONE FOR FAN MOTOR E 1 OPTIONAL PARTS C40051 FAN MOTOR R 1 C40052 INLET CONE FOR FAN MOTOR R 1 C50159 12 SUPPLY PANEL 1 C50160 16 SUPPLY PANEL 1 ...

Страница 19: ... C50127 FAN MOUNT 1 2 C50128 FAN POST 4 3 C50235 TRANSFORMER 1 4 C50257 CONTACTOR 1 5 C50131 BLACK CAM LOCK 1 6 C50132 RED CAM LOCK 1 7 C50133 BLUE CAM LOCK 1 8 C50134 GREEN CAM LOCK 1 9 C50239 FUSE HOLDER 1 10 C50241 60A FUSE 3 11 C50135 FUSE HOLDER 1 12 C50137 30A FUSE 3 13 C50240 FUSE HOLDER 1 ...

Страница 20: ...LUG 1 27 C70065 SELECTOR SWITCH 4 28 C70069 FIXING COLLAR 3 30 C50166 CONTACT BLOCK 3 31 C70072 FLIP LID COVER HOUSING 1 32 C40033 TEMPERATURE CONTROLLER 1 33 C50156 THERMOCOUPLE 1 34 C50313 ELEMENT 1 35 C50168 CASTER 4 36 C40029 FAN MOTOR E 1 37 C40030 INLET CONE FOR FAN MOTOR E 1 39 C50124 DEFLECTOR LEFT 1 40 C90041 LIMIT SWITCH 1 42 C50299 HINGE 2 43 C70087 GRAB HANDLE 1 44 C50298 LOCK 1 OPTION...

Страница 21: ... DECAL KIT C50320 SERIAL NUMBER VARIABLE DATA C50302 CAMPO LOGO C50303 CAUTION SHOCK RISK C50304 CAUTION BURN FIRE HAZ C50305 CAUTION CAM LOCKS C50306 DANGER MOVING PARTS C50307 DANGER HAZ VOLTAGE C50308 CAUTION AIR FLOW BLOCK C50309 MUST BE GROUNDED C50318 BLAZE 60E C50311 BUTTONS ...

Отзывы: