Version 1.03
April 2011
Chinook CBT
Page 12
G:\pubdata\Manuals\English Manuals\OM-CK24
OM CK24C/CK24F
GENERAL
INSTALLATION IS TO BE PERFORMED BY A QUALIFIED INSTALLER
The authority having jurisdiction (such a municipal building department, fire department, etc.)
should be consulted before installation to determine the need to obtain a permit.
Please take time to read these instructions thoroughly. Not following the instructions could
result in a faulty installation causing serious problems. Along with these general instructions
you must follow the specific instructions which pertain to your particular installation.
Blaze King grants no warranty, implied or stated, for the installation or maintenance of
the appliance and assumes no responsibility of any consequential damage(s).
Blaze King supports the WETT ( Wood Energy Technology Transfer Inc, Canada) & NFI
(National Fireplace Institute, USA). These organizations provide training and
certification for personnel involved in installation and maintenance of wood heating
systems.
FREIGHT DAMAGE
This product was carefully inspected before it left Blaze King. Inspect the unit thoroughly upon
its arrival. If damage is found report it to the carrier and then immediately file a freight damage
claim. Your local Blaze King dealer will assist if required.
PARTS INCLUDED WITH THE CHINOOK
1. Decorative Flue Ring
2. Poker
3. Fire Starter
4. This Manual
OPTIONAL EQUIPMENT
1. Fan kit
2. Rear shield
3. Ash drawer kit
FLOOR PROTECTION
If the stove sits on a combustible floor, a non-combustible shield must be used underneath the
stove and extending 16 in. out from the charging end and 8 in. on either side of the fuel-
loading door in the USA. In Canada a non-combustible shield must be used underneath the
stove and extending 8 in. on either side and rear and 18 in. out of the charging end.
A non-combustible shield is
also
required underneath the chimney connector and extending
at
least 2 in. on either side of the chimney connector
.
See next two pages for min. sizes depending on model. This floor protection is required to
prevent sparks from falling onto the combustible floor. See CSA B365-M87). It is not required
to be a heat protective covering.