The Tuscany
by Blaze King
Owners Installation and Operation Manual
OM-6003T
Page 36
DATE PRINTED: 4/3/14
Version 1.10 SIT
PART NAME
PART #
Gas Valve convertible—SIT
SIT0820652
Relief Plate gasket
6097
Burner Orifice Propane
#53
Burner Orifice Nat. Gas
#37
2 piece log set
M0814
Brick Panel Right
6062
Brick Panel Left
6063
Brick Panel Rear
6061
Brick Panel Base
6060
Brick Panel base Right
6103
Brick Panel Base Left
6104
Brick panel clip
6065
Rheostat Fan Control w/off
0136
Door Assembly—Black
Z6018P-C
Door Assembly—Gold
Z6018G-C
Main Door Rope Seal
0188
Fan Switch 130F
1144AA
Piezo igniter with nut
SIT0073952
PART NAME
PART #
Fan assembly
0719B
ON/OFF rocker switch
0725
Spark igniter electrode
0738B
Thermopile generator
0721A
Thermocouple
0842VC
Pilot assembly
Z6003P
Burner tray Assembly
Z9919
Orifice spring
0723
30% Restrictor
6082
60% Restrictor
6094
70% Restrictor
6095
75% Restrictor
6097
Bag of Fiber Embers
0745
LPG Conversion Kit—SIT
(0-2000ft USA / 0-4500ft Canada)
Z0760P
Replacement Parts List
PROBLEM
POSSIBLE CAUSE
CORRECTIVE ACTION
The main burner
does not turn on
with the pilot lit.
Gas valve not in on position.
Faulty thermopile.
Faulty unit on/off switch.
Faulty thermostat.
Faulty Gas Valve
Check to make sure the control knob is turned to the ‘
ON
’ position.
Check for correct millivolts at the thermopile, it should generate at
least 250mv.
Place jumper wire across terminals
TH-THTP
, if burner comes on this
will indicate you have a poor connection or faulty appliance
on/off
switch, wall switch or wall thermostat.
Check the minimum inlet gas supply pressure, if the minimum
pressure is present then try changing the gas valve.
The main burner
shuts off when
the appliance is
warm.
Pilot flame lifting of
thermopile.
Check thermopile voltage from start up. If the millivolts drop
dramatically it is an indication that the pilot is lifting. Check the vent is
correctly attached.
Excessive soot
on burner or
logs.
Incorrect aeration
adjustment.
Incorrect venting.
Check aeration setting.
Check that venting is correctly attached.
Troubleshooting
Please check to make sure the instructions are followed exactly before attempting trouble shooting of the appliance.
WARNING:
Trouble shooting and servicing of gas and electrical devices of the appliance should only be conducted by a
qualified service technician.
CAUTION:
Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and
dangerous operation. Verify proper operation after servicing.