background image

 

” + “3”   

Enable dual key Fire Alarm function 

” + “4”   

Enable dual key Medical Alarm function 

” + “5” 

Disable all dual key functions 

” + “6” 

Change Keypad PIN Code: 
1. Enter old code + “Status” Key 
2. Enter new 4-

digit code + “#” key 

” + “8” 

Enable  Arming  without  Use  PIN  code 
function 

” + “9” 

Enable Arm with User PIN code function 
(

Default

” + “0” 

Enable  Arming  with  KP  PIN  code 
function 

“Disarm” twice 

To leave Test Mode 

R

R

F

F

I

I

D

D

 

 

T

T

A

A

G

G

 

 

M

M

a

a

n

n

a

a

g

g

e

e

m

m

e

e

n

n

t

t

 

 

The  Keypad  can  function  with  the  RFID  tags  included  in  the 
package. By assigning User PIN Code to a Tag, you can use the 
Tag to Arm/Home/Disarm the Control Panel with a simple swipe. 

Up  to  6  tags can  be stored  in the  Keypad  and  assigned to  User 
PIN Codes for panel control: 

Add New Tag: 

1.  Enter Keypad Test Mode. 

2.  Enter 

”+“1” for Tag Management. Red Status LED will light up. 

3.  Enter a 4-digit 

“Control Panel User PIN Code” + “

#

 

key. 

Status 

RED 

LED 

flashes 

Success 

Status 

Blue 

LED 

flashes with 4 beeps 

Error: Wrong PIN Code length 

Status 

Red 

LED 

flashes with 4 beep 

Error: Keypad already stored 6 Tags 

4.  Put  the  TAG  close  to  the  Keypad  when  Status  Red  LED  is 

flashing.   

Status  RED  LED  On 
with 2 beeps 

Success 

Status  Red  LED  On 
with 1 bee 

Same  PIN  Code  already  assigned  to 
this Tag 

Status  Red  LED  On 
with 4 beeps 

Error:  Tag  already  assigned  to  another 
User PIN Code 

5.  After  finish  adding  new  Tag,  press 

“Disarm”  key  to  exit  Tag 

Management. 

Remove Existing Tag: 

1.  Enter Keypad Test Mode. 

2.  Enter 

”+“1” for Tag Management. Red Status LED will light 

up. 

3.  Enter the User PIN Code of the Tag you want to remove, then 

press the Status key. 

4.  The Keypad will emit a long beep, the Tag info is removed. 

A

A

r

r

m

m

/

/

H

H

o

o

m

m

e

e

/

/

D

D

i

i

s

s

a

a

r

r

m

m

 

 

If  Remote  Keypad  is  set  to 

“Arm with Use  PIN code” (“

” + “9” 

under Test Mode) 

Away Arm 

1.  Enter  a  Control  Panel  User  PIN  Code  + 

“Arm” Key. 

2.  Press 

“Arm” Key + put Tag on Keypad. 

Home Arm 

1.  Enter  a  Control  Panel  User  PIN  Code  + 

“Home” Key. 

2.  Press 

“Home” Key + put Tag on Keypad. 

Disarm 

1.  Enter  a  Control  Panel  User  PIN  Code  + 

“Disarm” Key. 

2.  Press 

“Disarm” Key + put Tag on Keypad. 

If Remote Keypad is set to 

“Arm without Use PIN code” (“

” + “8” 

under Test Mode) 

Away Arm 

Press 

“Arm” Key 

Home Arm 

Press 

“Home” Key 

Disarm 

Enter  a  Control  Panel  User  PIN  Code  + 

“Disarm” Key 

If  Remote  Keypad  is  set  to 

“Arm with  Keypad PIN code” (“

” + 

“0” under Test Mode) 

Away Arm 

Enter Keypad PIN Code + 

“Arm” Key 

Home Arm 

Enter Keypad PIN Code + 

“Home” Key 

Disarm 

Enter Keypad PIN Code + 

“Disarm” Key 

C

C

h

h

e

e

c

c

k

k

i

i

n

n

g

g

 

 

C

C

o

o

n

n

t

t

r

r

o

o

l

l

 

 

P

P

a

a

n

n

e

e

l

l

 

 

S

S

t

t

a

a

t

t

u

u

s

s

 

 

Press  the  Status  key  to  inquire  Control  Panel  status,  the  Status 
LED will light up according to Control Panel mode 

Red LED On 

Away Arm mode 

Red LED Flash 

Home Arm mode 

Blue LED on 

Disarm mode 

D

D

u

u

a

a

l

l

 

 

K

K

e

e

y

y

 

 

A

A

l

l

a

a

r

r

m

m

 

 

F

F

u

u

n

n

c

c

t

t

i

i

o

o

n

n

 

 

Dual  Key  Alarm  function  will  activate  alarm  when  both  keys  are 
pressed  at  the  same  time.  To  use  the  functions,  please  enable 
them under Test Mode. (Default are disabled) 

“1” + “3” 

Panic Alarm 

“4” + “6” 

Fire Alarm 

“7” + “9” 

Emergency Alarm 

L

L

E

E

D

D

 

 

I

I

n

n

d

d

i

i

c

c

a

a

t

t

o

o

r

r

s

s

 

 

 

 

A

A

c

c

t

t

i

i

v

v

e

e

 

 

L

L

E

E

D

D

 

 

The Active LED light up whenever any key is pressed. 

Off 

Keypad in Standby Mode 

Blue LED On 

Keypad in Normal Operation 

Blue LED Flash 

Keypad  in  Normal  Operation  and  under 
Low Battery 

Orange LED On 

Keypad in Test Mode 

Orange LED Flash  Keypad  in  Test  Mode  and  under  Low 

Battery 

 

 

S

S

t

t

a

a

t

t

u

u

s

s

 

 

L

L

E

E

D

D

 

 

The Status LED light up during operation or when the 

“Status” key 

is pressed to inquire Control Panel status 

Red LED On 

Away Arm mode 

Red LED Flash 

Home Arm mode 

Blue LED On 

Disarm mode 

Blue LED Flash 

No reply from Control Panel 

Incorrect PIN code 
Request  for  Home  arm  when  under  Away 
arm mode 

Request for Force Arm 

 

 

F

F

a

a

u

u

l

l

t

t

 

 

L

L

E

E

D

D

 

 

The Fault LED light up whenever faults are detected in the alarm 
system. 

Orange LED On 

Alarm in memory 

Orange LED Off 

Fault exists in system 

B

B

a

a

t

t

t

t

e

e

r

r

y

y

 

 

The  Remote  Keypad  uses  one  3V  lithium  battery  as  its  power 
source. It also features low battery detection function to notify the 
Control Panel when battery voltage is low. 

When the Remote Keypad is on low battery, follow the procedure 
below to change the batteries. 

1. Open the back cover 

2. Remove the old batteries 

3. Press any key several times to fully discharge. 

4. Insert the new batteries observing correct polarity.   

5. Replace the back cover. 

F

F

a

a

c

c

t

t

o

o

r

r

y

y

 

 

R

R

e

e

s

s

e

e

t

t

 

 

If  you  forget  your  Keypad  PIN  code,  or  the  Remote  Keypad  has 
any  problem,  you  can  reset  the  Remote  Keypad  to  factory 
default. 

1. Open the back cover and remove the battery 

2. Press and hold 

“3” key and insert battery 

Отзывы: