23

MOUNTING AND SETUP

The fan is designed for ceiling or wall mounting to extract air into a 
ventilation shaft or matching air duct of respective diameter (fig. 3-7).

The fan mounting sequence is shown in fig. 8.
The fan wiring diagrams are shown in fig. 9-14.

Fig. 5

Fig. 3 

Fig. 4

Содержание Quatro 100

Страница 1: ...Service Instructions Quatro EN ...

Страница 2: ...ts operation and mounting guidelines safety precautions and warnings for safe and correct operation of the fan BLAUBERG Quatro USE The BLAUBERG Quatro fan is designed for exhaust ventilation of residential and public premises heated during winter season The fan is designed for wall or ceiling mounting fig 3 5 The fan is equipped with a back valve to prevent air back drafting during the fan standby...

Страница 3: ...han 5 years 19 BASIC CHARACTERISTICS The fan designations delivery set options parameters outer view overall and connecting dimensions are shown in tables 1 2 3 and in fig 1 and 2 Type Max air flow 3 m h Power W Noise level 3 m dBA RPM min 1 Quatro 100 Quatro 125 Quatro 150 14 2300 88 33 16 2400 167 34 24 2400 265 37 Quatro ___ Quatro ___ S Quatro ___ T Quatro ___ ST Quatro ___ H Quatro ___ SH Swi...

Страница 4: ... 3 casing 4 motor 5 impeller 6 back valve 1 2 3 4 5 6 a 171 201 236 a1 151 178 207 d 100 125 150 e 32 35 38 Dimensions mm 0 56 0 73 0 9 Type Quatro 100 Quatro 125 Quatro 150 b 108 113 165 c 128 136 157 Table 3 Weight kg Fig 2 ...

Страница 5: ...nting and servicing operations are allowed for duly qualified electricians with valid electrical work permit for electric operations at the units up to 1000 V after careful study of the present user s manual The single phase power grid must comply with the acting local electrical norms and standards The fixed electrical wiring must be equipped with an automatic switch that is used for connection o...

Страница 6: ...air supply must be provided for proper combustion and exhaust of gases through the chimney of fuel burning equipment to prevent back drafting The maximum permitted pressure difference per living units is 4 Pa Transported medium must not contain any dust or other solid impurities sticky substances or fibrous materials The fan is not rated for operation in a media that contains hazardous or explosiv...

Страница 7: ...esigned for ceiling or wall mounting to extract air into a ventilation shaft or matching air duct of respective diameter fig 3 7 The fan mounting sequence is shown in fig 8 The fan wiring diagrams are shown in fig 9 14 Fig 5 Fig 3 Fig 4 ...

Страница 8: ...24 Fig 6 Fig 7 Fig 8 ...

Страница 9: ... ____ S external switch QF automatic switch QUATRO ____ S QF automatic switch QF S L N N L QF S L N N L QF N L 25 S Fig 9 Fig 10 Fan does not run Switch is closed Fan runs Switch is opened Fan does not run Pull cord switch Fan runs Pull cord switch ...

Страница 10: ...h S 2min 30min T 2min 30min T QF L N LT N L QF S L N LT N L QF S L N LT N L Fig 11 Fig 12 Fan does not run Fan runs Turn off delay timer starts 2 to 30 min Pull cord switch Pull cord switch Fan does not run Switch is closed Fan runs Switch is opened Turn off delay timer starts 2 to 30 min ...

Страница 11: ...QF S L N LT N L QF S L N LT N L Fig 13 Fan does not run Turn off delay timer starts 2 to 30 min Humidity is below set point Humidity exceeds set point Switch is closed Fan runs yes no Fan runs Switch is opened Humidity is below set point Humidity exceeds set point Fan runs yes no ...

Страница 12: ...F L N LT N L Fig 14 Fan does not run Turn off delay timer starts 2 to 30 min Humidity is below set point Humidity exceeds set point Fan runs yes no Fan runs Humidity is below set point Humidity exceeds set point Fan runs Pull cord switch Pull cord switch yes no ...

Страница 13: ... operations The fan delivery set includes a specially designed plastic screwdriver for fan settings adjustments Use the screwdriver to adjust the turn off delay time or the humidity threshold Do not use a screwdriver knife etc for adjustment operations not to damage the circuit board 2min 30min T 60 90 H Fig 15 ...

Страница 14: ...The storage environment must be free of dust acid or alkali vapours to prevent corrosion DISPOSAL Do not dispose in domestic waste The unit contains in part material that can be recycled and in part substances that should not end up as domestic waste Dispose of the unit once it has reached the end of its working life according to the regulations valid where you are MANUFACTURER S WARRANTY The fan ...

Страница 15: ...operation of the fan over the period of five years from the retail sale date provided observance of the installation and operation regulations In case of failure due to faulty equipment during the warranty period the consumer has the right to exchange it The replacement is offered by the Seller If case of no confirmation of the sale date the warranty period shall be calculated from the manufacturi...

Страница 16: ...100 125 QUATRO 150 S T H ST SH QUATRO_DE_EN 02 SALES DATE MANUFACTURED ON DATE SOLD APPROVAL MARK model is recognized as serviceable ...