BLAUBERG Centro-M EC 100 Скачать руководство пользователя страница 5

www.blaubergventilatoren.de

Centro-M EC

5

The fab is designed for indoor or sheltered application at ambient temperature from -25°C up to +40°C and relative humidity up to 80 %. 
The unit is rated as a class I electric appliance.
Ingress protection rating against access to hazardous parts and water ingress is IPX4.
The unit design is constantly being improved, thus some models may be slightly different from those described in this manual.

Terminal box

Casing

Impeller

EC motor

Fixing bracket 

L

øD1

B

B1

L2

L3

L1

H

øD

ø6
4 holes

TECHNICAL DATA

Centr

o-M EC 100 

Centr

o-M EC 125  

Centr

o-M EC 150  

Centr

o-M EC 160  

Centr

o-M EC 200  

Centr

o-M EC 200 max 

Centr

o-M EC 250   L

Centr

o-M EC 250  

Centr

o-M EC 315  

Centr

o-M 

EC 315 

 max

Power supply voltage, 50 (60) Hz [V]

1~220-277

Max. power consumption [W]

90

83

98

95

83

100

100

164

164

270

Current consumption [A]

0,70

0,58

0,73

0,72

0,63

0,74

0,74

1,15

1,15

1,80

Air capacity [m3/h]

345

480

620

685

845

1010

985

1230

1370

2100

Noise level, 3 m [dB(A)] 

44

45

47

47

47

48

44

46

48

51

Transported air temperature [˚C] 

-25...+40

SEC class

B

D

D1

H

B

B1

L

L1

L2

L3

 Centro-M EC 100

98

255

340

310

270

203

20

25

30

 Centro-M EC 125

123

255

340

310

270

203

20

25

30

 Centro-M EC 150

149

305

365

360

320

220

25

25

30

 Centro-M EC 160

159

305

365

360

320

220

25

25

30

 Centro-M EC 200

198

345

435

395

355

245

25

30

40

 Centro-M EC 200 max

198

345

435

395

355

255

25

30

40

 Centro-M EC 250 L

248

345

435

395

355

250

25

30

40

 Centro-M EC 250

248

345

435

395

355

250

25

30

40

 Centro-M EC 315

314

405

465

455

415

260

30

30

40

 Centro-M EC 315 max

313

410

420

505

475

440

60

60

50

TECHNICAL DATA

Содержание Centro-M EC 100

Страница 1: ...Centro M EC CENTRIFUGAL INLINE FAN USER S MANUAL EN ...

Страница 2: ...tion systems and should be able to work in accordance with workplace safety rules as well as construction norms and standards applicable in the territory of the country The information in this user s manual is correct at the time of the document s preparation The Company reserves the right to modify the technical characteristics design or configuration of its products at any time in order to incor...

Страница 3: ... the electric parts of the unit against ingress of water Do not allow children to operate the unit Disconnect the unit from power mains prior to any technical maintenance Do not allow children to operate the unit When the unit generates unusual sounds odour or emits smoke disconnect it from power supply and contact the Seller Do not open the unit during operation Do not direct the air flow produce...

Страница 4: ...erms NAME QUANTITY Fan 1 pc Fixing bracket 2 pcs User s manual 1 pc Packing box 1 pc THE UNIT SHOULD NOT BE OPERATED BY CHILDREN OR PERSONS WITH REDUCED PHYSICAL MENTAL OR SENSORY CAPACITIES OR THOSE WITHOUT THE APPROPRIATE TRAINING THE UNIT MUST BE INSTALLED AND CONNECTED ONLY BY PROPERLY QUALIFIED PERSONNEL AFTER THE APPROPRIATE BRIEFING THE CHOICE OF UNIT INSTALLATION LOCATION MUST PREVENT UNAU...

Страница 5: ...entro M EC 315 max Power supply voltage 50 60 Hz V 1 220 277 Max power consumption W 90 83 98 95 83 100 100 164 164 270 Current consumption A 0 70 0 58 0 73 0 72 0 63 0 74 0 74 1 15 1 15 1 80 Air capacity m3 h 345 480 620 685 845 1010 985 1230 1370 2100 Noise level 3 m dB A 44 45 47 47 47 48 44 46 48 51 Transported air temperature C 25 40 SEC class B D D1 H B B1 L L1 L2 L3 Centro M EC 100 98 255 3...

Страница 6: ... straight air duct length qual to 1 air duct diameter on intake side equal to 3 air duct diameters on outlet side min D min 3D D If the air ducts are too short or not connected at any spigot protect the fan inner parts from ingress of foreign objects by installing a protecting grille or other protecting device with mesh width not more than 12 5 mm to prevent uncontrollable access to the fans While...

Страница 7: ...C 7 INSTALLATION STEPS Disconnect the fan from power supply Install the fixing brackets Lean the fan against the installation place and mark the fastening holes Drill the holes and insert the expansion anschors Fix the fan Connect air ducts ...

Страница 8: ...r emergency shutdown of the fan Connection of the fan to power supply is performed via the terminal block located in the terminal box attached to the fan casing in compliance with the wiring diagram and designation of terminals For smooth air flow control it is recommended to use the speed controller CDT E 0 10 The speed controller is not included in the delivery set and is available as a speciall...

Страница 9: ...ro M EC 9 ACCESS TO THE TERMINAL BOX Disconnect the fan from power supply Unscrew the 4 screws that fix the terminal box lid Route the cables through the cable glad and complete electric connection Install the terminal box cover again ...

Страница 10: ...on of an air filter prolongs the interval between the cleaning To perform the cleaning first remove the screws and the fan cover Wipe the impeller blades with a cloth wetted in a mild detergent solution Avoid water dripping on the electric motor After cleaning of the impeller install the cover and tighten the screws TECHNICAL MAINTENANCE STEPS DISCONNECT THE UNIT FROM POWER SUPPLY BEFORE ANY MAINT...

Страница 11: ...inery for handling and storage operations to prevent possible damage to the unit Follow the handling requirements applicable for the particular type of cargo The unit can be carried in the original packaging by any mode of transport provided proper protection against precipitation and mechanical damage The unit can be transported only in the working position Avoid sharp blows scratches or rough ha...

Страница 12: ... user Mismatch of the unit model and the brand name with the information stated on the unit packaging and in the user s manual User s failure to ensure timely technical maintenance of the unit External damage to the unit casing excluding external modifications as required for installation and internal components caused by the user Redesign or engineering changes to the unit Replacement and use of ...

Страница 13: ...d technical codes and standards The unit operates normally as intended by the manufacturer Signature Seller s Stamp Unit Type Centrifugal inline fan Model Centro M EC _____________ Serial Number Manufacture Date Purchase Date Warranty Period Seller Unit Type Centrifugal inline fan Model Centro M EC _____________ Serial Number Manufacture Date Quality Inspector s Stamp The product is in compliance ...

Страница 14: ...www blaubergventilatoren de Centro M EC 14 ...

Страница 15: ...www blaubergventilatoren de Centro M EC 15 ...

Страница 16: ...www blaubergventilatoren de B88EN 04 ...

Отзывы: