background image

www.blaubergventilatoren.de

3

Axis / Tubo

BLAUBERG Company is happy to offer your attention the new high-quality 

axial fans Blauberg Axis and Blauberg Tubo.

 

The solid team of high-qualified 

professionals with many years of working experience, technological 

innovations in design and production, high-quality components and 

materials from the top worldwide producers have become the precondition 

for the best fan in its class. 

INTRODUCTION

The present operation manual contains technical description, technical data 

sheets, operation and mounting guidelines, safety precautions and warnings 

for safe and correct operation of the fan. 

GENERAL

The axial fans Axis, Tubo are not a ready for use product. It is a component 

unit designed for integration into air conditioning and ventilation systems. 
The fans Axis-Q, Axis-QR, Axis-QA, Axis-QRA are designed for direct air 

exhaust. The models Axis-F are designed for connection to Ø 205 mm up 

to 645  mm air ducts and the models Tubo-M, Tubo-MZ are designed for 

connection to Ø 160 mm up to 315 mm air ducts.  
The fan has IEC Protection Class I and must be grounded.  
The fans are allowed for operation only after final mounting, that includes 

installation of protecting devices in compliance with DIN EN ISO 13875 (DIN 

EN ISO 12100) as well as other construction safety equipment. 
The fan design is regularly improved, so some models can slightly differ from 

those ones described in this service instruction.

SAFETY RULES

The fan complies with the requirements according to the EU norms and 

directives, to the relevant EU-Low Voltage Equipment Directives, EU-

Directives on Electromagnetic Compatibility. 
All operations related to the fan electrical connections, servicing and repair 

works are allowed only after the fan disconnection from power mains.  
All mounting and servicing operations are allowed for duly qualified 

electricians with valid electrical work permit for electric operations at the 

units up to 1000 V after careful study of the present user's manual. 
Please follow the safety regulations and working instructions (DIN EN 50 110, 

IEC 364).
Make sure the impeller and the casing are not damaged before connecting 

the fan to power mains. The casing internals must be free of any foreign 

objects which can damage the impeller blades.
Disconnect the fan from power mains prior to any operations related to the 

fan servicing and repair works.
Take measures to prevent contact with the fan to avoid physical damages 

during the fan step and start-up. 
Misuse of the product or any unauthorized modification are not allowed. 
The fan is designed for connection to ac single-phase or ac three-phase 

power mains, see „Technical Data“. The fan is rated for permanent operation 

during non-stop power supply. 
Take steps to prevent ingress of smoke, carbon monoxide and other 

combustion products into the room through open chimney flues or other 

fire-protection devices. Sufficient air supply must be provided for proper 

combustion and exhaust of gases through the chimney of fuel burning 

equipment to prevent back drafting.  The maximum permitted pressure 

difference per living units is 4 Pa.
The transported air must not contain any dust or other solid impurities, sticky 

substances or fibrous materials.
The fan is not designed for use in an inflammable and explosive medium. 
The transported medium must not have an aggressive effect on steel at the 

temperature stated on pages 5–8  of the section „Technical data”. 
Do not close or block the fan intake or exhaust vent not to disturb the normal  

air passage. Do not sit on the fan and do not put objects on the fan.
Follow the manual guidelines to ensure trouble-free operation and long 

service life of the product.

STORAGE AND TRANSPORTATION RULES

Store the delivered product in the manufacturer's original packing box in 

a dry ventilated premise with the ambient temperature  from +5 °C up to 

+40 °C and relative humidity less than 80 % at the tempe25 °C . 
Store the fan in an environment with minimized risk of mechanical damages, 

temperature and humidity fluctuations. Store the fan inside a room or under 

a shelter.  
Transport of the product is allowed by any vehicle in the manufacturer's 

original packing box.  Use hoist machinery for handling and transportation to 

prevent possible mechanical damages of the product. Fulfil the requirements 

for transportation of the specified cargo type during cargo-handling 

operations. 
Do not expose the product to extremely low or high temperatures.

MANUFACTURER'S WARRANTY

The fan complies with the requirements according to the EU norms and 

directives, to the relevant EU-Low Voltage Equipment Directives, EU-

Directives on Electromagnetic Compatibility. 
We hereby declare that the following product complies with the essential 

protection requirements of Electromagnetic Council Directive 2004/108/

EC, 89/336/EEC and Low Voltage Directive 2006/95/EC, 73/23/EEC and 

CE-marking Directive 93/68/EEC on the approximation of the laws of the 

Member States relating to electromagnetic compatibility. This certificate is 

issued following test carried out on samples of the product referred to above. 

Assessment of compliance of the product with the requirements relating to 

electromagnetic compatibility was based on the following standards.
The manufacturer hereby warrants normal operation of the fan over the 

period of 2 years from the retail sale date provided observance of the 

installation and operation regulations.
In case of failure due to faulty equipment during the warranty period the 

consumer has the right to exchange it.
If case of no confirmation of the sale date, the warranty term shall be 

calculated from the manufacturing date.
The replacement is offered by the Seller. 
The MANUFACTURER shall not be liable for any damage resulting from any 

misuse of or gross mechanic interference with the fan.
Please follow the operation guidelines always.

 

              WARNING

 

Do not dispose in domestic waste. 

The unit contains in part material that can be recycled 

and in part substances that should not end up as 

domestic waste.

Dispose of the unit once it has reached the end of its 

working life according to the regulations valid where you 

are.

 

                  ATTENTION

 

The product is not allowed for use by children and persons with reduced 

physical, mental or sensory capacities, without proper practical 

experience or expertise, unless they are controlled or instructed on the 

product operation by the person(s) responsible for their safety. Supervise 

the children and do not let them play with the product. 

!

Содержание Axis series

Страница 1: ...OPERATION MANUAL AXIAL FANS Axis Tubo EN AXIS QRA AXIS QA G AXIS Q TUBO F AXIS QA TUBO M MZ AXIS QR AXIS F ...

Страница 2: ... 3 Transport and storage requirements 3 Manufacturer s warranty 4 Fan design 4 Delivery set 4 Modifications and options 5 Technical data 10 Mounting and operation guidelines 11 Mounting sequence 11 Installation and connection to power mains 13 Maintenance 14 Warranty card CONTENT ...

Страница 3: ...not contain any dust or other solid impurities sticky substances or fibrous materials The fan is not designed for use in an inflammable and explosive medium The transported medium must not have an aggressive effect on steel at the temperature stated on pages 5 8 of the section Technical data Do not close or block the fan intake or exhaust vent not to disturb the normal air passage Do not sit on th...

Страница 4: ...AXIS QRA FAN DESIGN AXIS F FAN DESIGN TUBO M TUBO MZ MODIFICATIONS AND OPTIONS MODIFICATIONS AND OPTIONS flange impeller cover casing casing terminal block impeller mounting bracket TUBO M Fan made of polymer coated steel TUBO MZ Fan made of galvanized steel AXIS Q Fan with a square mounting plate AXIS QR Fan with a round mounting plate Fig 1 Fig 2 Fig 3 fan 1 item operation manual flange impeller...

Страница 5: ...60 50 60 50 60 50 60 Power W 75 92 140 147 180 240 250 325 Current A 0 35 0 4 0 65 0 66 0 82 1 08 1 2 1 46 Max air flow m3 h 1340 1475 2500 2650 3580 3890 4680 4790 RPM min 1 1350 1405 1380 1700 1380 1655 1350 1600 Noiselevel 3m dBA 58 59 62 63 63 64 64 65 Max transported air temperature C 30 60 30 50 30 60 30 50 30 60 30 50 30 60 30 50 Ingress Protection Rating IP24 Axis F IPX4 IP24 Axis F IPX4 I...

Страница 6: ...370 320 155 4 2 Axis Q 250 4E Axis Q 250 4D 260 7 370 320 155 4 1 Axis Q 300 2E 326 9 430 380 195 5 3 Axis Q 2 300 D 326 9 430 380 155 5 3 Axis Q 300 4E 326 9 430 380 195 5 1 Axis Q 300 4D 326 9 430 380 155 5 1 Axis Q 350 4E Axis Q 350 4D 388 9 485 435 200 7 1 Axis Q 400 4E Axis Q 400 4D 417 9 540 490 240 8 8 Axis Q 450 4E Axis Q 450 4D 465 11 576 535 250 10 6 Axis Q 500 4E Axis Q 500 4D 520 11 65...

Страница 7: ...65 605 636 11 5 660 230 17 3 13 9 Axis F 630 4E Axis F 630 4D 645 674 715 11 5 740 250 20 13 16 4 Type Dimensions mm Weight kg Ø D Ø D1 Ø D2 Ø d L Axis QR 200 2E 210 250 280 7 145 2 5 Axis QR 250 2E Axis QR 250 2D 260 295 320 7 155 3 4 Axis QR 250 4E Axis QR 250 4D 260 295 320 7 155 3 4 Axis QR 300 2E 326 380 397 9 195 4 4 Axis QR 300 2D 326 380 397 9 155 4 4 Axis QR 300 4E 326 380 397 9 195 4 7 A...

Страница 8: ...ght kg Ø D Ø d B B1 L Axis QA 150 162 7 250 210 120 2 5 Axis QA 200 208 7 312 260 120 3 0 Axis QA 250 262 7 370 320 140 3 5 Axis QA 315 312 9 430 380 170 6 1 Overall dimensions Tubo F 200 2E Tubo F 250 2E Tubo F 250 4E Tubo F 300 2E Tubo F 300 4E Tubo F 350 4E Voltage 50 Hz V 230 230 230 230 230 230 Power W 55 80 50 145 75 140 Current A 0 26 0 4 0 22 0 66 0 35 0 65 Max air flow m3 h 860 1050 800 2...

Страница 9: ... Tubo MZ 250 262 283 270 55 30 3 7 Tubo M 315 Tubo MZ 315 315 337 278 55 40 4 9 The Tubo M fans are equipped with MD polymer coated steel and MDZ Zn galvanised steel reducers for connection to 150 mm 200 mm and 250 mm air ducts The reducers are not included in the delivery set and must be ordered separately Tubo F Axis QA G Type Dimensions mm Weight kg Ø D Ø d B B1 L Axis QA 150 G 162 7 325 275 12...

Страница 10: ...ent and quick access for servicing and repair operations The fan must be grounded While mounting protect the fan against water ingress in the following way 1 Install an outer hood above in case of vertical mounting position fig 13 MOUNTING SEQUENCE Fig 13 Fig 14 Fig 22 Fig 15 Fig 23 Fig 16 Fig 18 Fig 20 Fig Fig 17 Fig 21 Fig 19 AXIS Q AXIS QR AXIS QA AXIS QRA Fig 24 Fig 25 Fig 26 Fig 27 ...

Страница 11: ...h an automatic switch at the external input Connect the fan to power mains through the automatic switch The contact gap on all poles at least 3 mm The automatic switch trip current must be in compliance with the fan current consumption refer Table on pag es 5 6 Install the automatic switch to ensure prompt access Cut power supply to the fan off by turning the automatic electric switch QF to OFF po...

Страница 12: ...o INSTALLATION AND CONNECTION TO POWER MAINS AXIS QA AXIS QRA TUBO M TUBO MZ TUBO M TUBO MZ Fig 50 Fig 51 Fig 52 Fig 53 Fig 42 Fig 43 Fig 44 Fig 45 AXIS Q AXIS QR AXIS F Fig Fig 47 Fig 46 Fig 54 Fig 56 Fig Fig 48 Abb Fig 49 Fig 55 AXIS QA G ...

Страница 13: ...e impeller motor impeller blades Mounting sequence of the fan is shown on fig 59 70 Clean the impeller blades with a soft cloth or a brush wetted in a mild soap solution Avoid liquid splashing on the motor Clean the impeller blades thoroughly at least once in 6 months Operation recommendations 1 Clean the fan regularly from dust dirt and foreign objects 2 Check all fastening connections periodical...

Страница 14: ... EEC on the approximation of the laws of the Member States relating to electromag netic compatibility which relate to electrical appliances used in set voltage classes This certificate is issued following test carried out on samples of the product referred to above Quality Inspector s Stamp Manufacture Date ____________________ Company Expert s Full Name Date Signature Axial fans Axis___________ T...

Страница 15: ...www blaubergventilatoren de 15 Axis Tubo ...

Страница 16: ...BL_AXIS_4 8 _EN www blaubergventilatoren de ...

Отзывы: