SAFETY RULES 

All operations related to the fan electrical connections, servicing and 
repair works are allowed only after the fan disconnection from power 
mains.  

All mounting and servicing operations are allowed for duly qualified 
electricians with valid electrical work permit for electric operations at the 
units up to 1000 V after careful study of the present user's manual. 
The single-phase power grid must comply with the acting local electrical 
norms and standards. The fixed electrical wiring must be equipped with 
an automatic switch that is used for connection of the fan to power mains 
with gap on all poles at least 3 mm. 

Make sure the impeller and the casing are not damaged before starting 
installation. The casing internals must be free of any foreign objects 
which can damage the impeller blades. Misuse of the product or any 
unauthorized modification are not allowed. 

The product is not allowed for use by children and persons with reduced 
physical, mental or sensory capacities, without proper practical 
experience or expertise, unless they are controlled or instructed on the 
product operation by the person(s) responsible for their safety. 
Supervise the children and do not let them play with the product. 
Take steps to prevent ingress of smoke, carbon monoxide and other 
combustion products into the room through open chimney flues or other 
fire-protection devices. Sufficient air supply must be provided for proper 
combustion and exhaust of gases through the chimney of fuel burning 
equipment to prevent back drafting. The maximum permitted pressure 
difference per living units is 4 Pa. Operating medium must not contain 
any dust or other solid impurities, sticky substances or fibrous materials.
The fan is not rated for operation in a media that contains hazardous or 
explosive materials and vapours, i.e. spirits, gasoline, insecticides, etc. 
Do not close or block the fan intake or exhaust vent not to disturb the 
natural air passage.

Do not sit on the fan and do not put objects on the fan.
Follow the guidelines of this service instructions to ensure durable 
operation of the product. 

22

Содержание Wind 125

Страница 1: ...Wind EN Service instruction...

Страница 2: ...iption technical data sheets operation and mounting guidelines safety precautions and warnings for safe and correct operation of the fan BLAUBERG Wind USE BLAUBERG Wind fan is designed for extract ven...

Страница 3: ...min Humidity sensor H humidity level range from 60 to 90 Motion sensor IR reach distance from 1 to 4 m and sensor viewing angle up to 100 Note Wind ___ Wind 125 Wind K 125 or Wind 150 The fan does not...

Страница 4: ...7 1 6 4 1 8 3 2 4 6 5 7 Wind 125 150 1 cover 2 casing 3 motor 4 impeller 5 inner flange 6 sealing gasket 7 outer flange Wind K 125 1 cover 2 casing 3 motor 4 impeller 5 inner flange 6 sealing gasket...

Страница 5: ...lways connected to power mains The air motion direction in the system must match the pointer on the fan casing The fan is rated for operation at ambient temperature from 1 C up to 45 C The fan does no...

Страница 6: ...uced physical mental or sensory capacities without proper practical experience or expertise unless they are controlled or instructed on the product operation by the person s responsible for their safe...

Страница 7: ...unting on a glass plate in the wall fig 4 5 or on a thin partition fig 6 7 and air extraction outside or to an adjacent room The fan mounting sequence is shown in fig 8 9 The fan wiring diagrams are s...

Страница 8: ...160 Hole diameter d mm Type Wind 125 Wind K 125 Wind 150 180 24 Fig 9 Fig 8 Table 4...

Страница 9: ...S external switch QF automatic switch Wind ___ Wind ___ S Fan does not run Switch is closed Fan runs Switch is opened Fan does not run Pull cord switch Fan runs Pull cord switch Fig 10 Fig 11 L N S QF...

Страница 10: ...not run Fan runs Turn off delay timer starts 2 to 30 min Pull cord switch Pull cord switch Fan does not run Switch is closed Fan runs Switch is opened Turn off delay timer starts 2 to 30 min 26 Wind _...

Страница 11: ...timer starts 2 to 30 min Humidity is below set point Humidity exceeds set point Switch is closed Fan does not run yes no Fan runs Switch is opened Humidity is below set point Humidity exceeds set poin...

Страница 12: ...Turn off delay timer starts 2 to 30 min Humidity is below set point Humidity exceeds set point Fan runs yes no Fan runs Humidity is below set point Humidity exceeds set point Fan runs Pull cord switch...

Страница 13: ...s voltage Disconnect the fan from power mains prior to any adjustment operations The fan delivery set includes a specially designed plastic screwdriver for fan settings adjustments Use the screwdriver...

Страница 14: ...on vehicle provided that the product is in the manufacturer s original package Store the delivered product in the manufacturer s original packing box in a dry ventilated premise with the ambient tempe...

Страница 15: ...iance of the product with the requirements relating to electromagnetic compatibility was based on the following standards Protection degree index according to IP rating against access to hazardous par...

Страница 16: ...WIND_DE EN 02 SALES DATE MANUFACTURED ON DATE Wind 125 Wind K 125 Wind 150 S T H ST SH IR model is recognized as serviceable SOLD APPROVAL MARK...

Отзывы: