vento eco(2) a50-4 Pro

5

TECHNICAL DATA

The ventilator is rated for indoor application with the ambient temperature ranging from -15 °C (5 °F) up to +40 °C (104 °F) and relative 
humidity up to 50 %.
The unit is rated as a class II electric appliance.
Ingress protection rating against access to hazardous parts and water ingress is IP24.
The unit design is constantly being improved, thus some models may be slightly different from those described in this manual.

Technical specifications of the particular model are indicated on the unit casing.

Ø 160 (6 

5

/

16

")

Air duct length (wall thickness)

A

Outer ventilation hood

Indoor unit

215

(8  

7

/

16

")

60

(2 

3

/

8

")

250

(9 

13

/

16

")

160

(6 

5

/

16

")

160

(6 

5

/

16

")

80

(3 

1

/

8

")

80

(3 

1

/

8

")

55

(2 

3

/

16

")

55

(2 

3

/

16

")

Overall dimensions of the indoor unit [mm] (inch)

The air duct length depends on the unit model, refer to the Designation Key 
section, page 4.

Air duct length

Vento Eco A50-4 Pro

250 (150*)-500 (10”(6”)-20”)

Vento Eco A50-4 Pro

 L

250 (150*)-700 (10”(6”)-28”)

*Minimum air duct length with a hood for thin walls EH-2.

The supplied ventilation hood model depends on the ventilator model. The 
overall dimensions of the outer ventilation hood and the A distance are stated 
in the installation instruction.
The overall dimensions of the front panel are stated below.

Содержание Vento Eco A50-4 Pro Series

Страница 1: ...Single room reversible energy recovery ventilator USER S MANUAL EN Vento Eco A50 4 Pro Vento Eco2 A50 4 Pro...

Страница 2: ...he field of ventilation systems and should be able to work in accordance with workplace safety rules as well as construction norms and standards applicable in the territory of the country The informat...

Страница 3: ...Protect the electric parts of the unit against ingress of water Do not allow children to operate the unit Disconnect the unit from power mains prior to any technical maintenance Do not store any expl...

Страница 4: ...ted air must not contain any flammable or explosive mixtures evaporation of chemicals sticky substances fibrous materials coarse dust soot and oil particles or environments favourable for the formatio...

Страница 5: ...dicated on the unit casing 160 6 5 16 Air duct length wall thickness A Outer ventilation hood Indoor unit 215 8 7 16 60 2 3 8 250 9 13 16 160 6 5 16 160 6 5 16 80 3 1 8 80 3 1 8 55 2 3 16 55 2 3 16 Ov...

Страница 6: ...manually actuated air damper WARNING Air damper closing does not turn off the ventilator but only blocks the air flow The external protective grille or the ventilation hood on the outer wall prevents...

Страница 7: ...sign VENTILATOR OPERATION MODES The ventilator has two operation modes Ventilation the ventilator runs either in extract or supply mode at a set speed In this mode when two ventilators are installed o...

Страница 8: ...mounting 1 Prepare a hole in the wall and route all the wires to the installation place Insert the supplied mounting box for flush wall mounting The mounting box is included in the delivery set 2 Use...

Страница 9: ...nce to a mounting surface for example a wall ceiling or a window as well as the minimum distance between the ventilators are shown below min 1 m min 1 m min 1 m min 500 mm 180 mm min 500 mm min 500 mm...

Страница 10: ...ion Mark the sound absorbing layer at the end of the air duct as 1 Cut the excessive part of the sound absorbing layer Insert the adjusted and ready sound absorbing layer into the air duct No glue is...

Страница 11: ...ilt into the stationary wiring The circuit breaker trip current must be selected depending on the ventilator current consumption For details please refer to the table on page 5 The actual conductor cr...

Страница 12: ...ir exhaust unit Each unit is connected as an air supply unit 100 240 V 50 60 Hz P1 T1 L N P2 T2 P2 T2 BLACK RED BLUE YELLOW BLACK RED BLUE YELLOW T P 100 240 V 50 60 Hz P1 T1 P1 T1 L N P2 T2 T P BLACK...

Страница 13: ...SpeedI 8hours REGENERATION VENTILATION The ALARM indicator glows in case of emergency stop of the motor as a result of which the unit stops Resetting alarm indication press and hold the ALARM indicato...

Страница 14: ...open or close the air duct turn one of the handles on the side walls of the indoor unit until it stops as shown in the figure The vertical position of the handle corresponds to the position OPEN the...

Страница 15: ...s as they get clogged but not less than once in three months After expiry of the period set for the hour meter factory setting 90 days the filter replacement indicator appears on the control panel dis...

Страница 16: ...ts and troubleshooting Problem Possible reasons Troubleshooting The fan does not start up during the ventilator start up The control panel displays no information and does not respond to the button pr...

Страница 17: ...arranty does not apply to the following cases User s failure to submit the unit with the entire delivery package as stated in the user s manual including submission with missing component parts previo...

Страница 18: ...www blaubergventilatoren de Vento Eco 2 A50 4 Pro 18...

Страница 19: ...of the complete unit delivery with the user s manual The warranty terms are acknowledged and accepted Customer s Signature The Vento Eco ____________ unit is installed pursuant to the requirements sta...

Страница 20: ...www blaubergventilatoren de B127 2EN 01...

Отзывы: