UNIT INSTALLATION
To get the best performance of the unit and to minimize turbulence-induced air pressure losses, connect the straight air duct section to
the spigots on both sides of the unit while installing. Minimum straight air duct length:
• equal to 1 air duct diameter on the intake side
• equal to 3 air duct diameters on outlet side
If the air ducts are too short or not connected, protect the unit parts from ingress of foreign objects. To prevent uncontrollable access to
the fan, the spigots may be covered with a protecting grille or other protecting device with mesh width not more than 12.5 mm.
While installing the unit, ensure convenient access for subsequent maintenance and repair. The unit must be mounted on a plane wall.
Installing the unit to an uneven surface could lead to the unit's casing distortion and operation disturbance.
UNIT WALL MOUNTING
Fasteners for wall mounting are not included in the delivery set and
should be ordered separately. While choosing fasteners consider
the material of the mounting surface as well as the weigh of the unit,
refer to the “Technical data” section. Fasteners for unit installation
should be selected by a qualified technician. Secure the wall bracket
at the desired level. Hang the unit on the bracket.
UNIT FLOOR MOUNTING
Install the unit on the pre-mounted floor supports, minimum
150 mm height, to ensure sufficient access for the drain pipe
connection to the U-trap and for condensate drain system
installation.
min 150 mm
Note:
mounting is shown by the example of the KOMFORT EC S(B)200(-E) unit.
CONDENSATE DRAINAGE
Condensate drainage is required for the KOMFORT EC S(B)200/250 units.
The hole for the drain pipe is at the bottom of the unit. Remove the plug from the hole, open the service panel and install the drain pipe
from the delivery set into the hole, then connect the drain pipe to the sewage system using the SFK 20x32-32 U-trap kit (available upon
separate order). The drain pipe must have a minimum slope of 3˚.