background image

www.blaubergventilatoren.de

Centro-M EC

3

SAFETY REQUIREMENTS

All user’s manual requirements as well as the provisions of all the applicable local and national 
construction, electrical, and technical norms and standards must be observed when installing 
and operating the unit.
Disconnect the unit from the power supply prior to any connection, servicing, maintenance, and 
repair operations. 

Only  qualified electricians with a work permit for electrical units up to 1000 V are 

allowed for installation. The present user’s manual should be carefully read before 

beginning works.

Check the unit for any visible damage of the impeller, the casing, and the grille before starting 
installation. The casing internals must be free of any foreign objects that can damage the 
impeller blades. 
While mounting the unit, avoid compression of the casing! Deformation of the casing may result 
in motor jam and excessive noise.
Misuse of the unit and any unauthorised modifications are not allowed.
Do not expose the unit to adverse atmospheric agents (rain, sun, etc.).
Transported air must not contain any dust or other solid impurities, sticky substances, or fibrous 
materials.
Do not use the unit in a hazardous or explosive environment containing spirits, gasoline, 
insecticides, etc.
Do not close or block the intake or extract vents in order to ensure the efficient air flow.
Do not sit on the unit and do not put objects on it.
The information in this user’s manual was correct at the time of the document’s preparation. 
The Company reserves the right to modify the technical characteristics, design, or configuration 
of its products at any time in order to incorporate the latest technological developments.
Never touch the unit with wet or damp hands.
Never touch the unit when barefoot.

This unit is not intended for use by persons (including children) with reduced physical, sensory 
or mental capabilities, or lack of experience and knowledge, unless they have been given 
supervision or instruction concerning use of the unit by a person responsible for their safety.
Children should be supervised to ensure that they do not play with the unit.
This appliance incorporates an earth connection for functional purposes.

Содержание Centro-M 355 EC

Страница 1: ...Centro M EC Centrifugal inline fan USER S MANUAL EN...

Страница 2: ...rranty card 13 CONTENTS This user s manual is a main operating document intended for technical maintenance and operating staff The manual contains information about purpose technical details operating...

Страница 3: ...unit to adverse atmospheric agents rain sun etc Transported air must not contain any dust or other solid impurities sticky substances or fibrous materials Do not use the unit in a hazardous or explosi...

Страница 4: ...ed off from the supply mains before removing the guard WARNING If there are any unusual oscillating movements immediately stop using the unit and contact the manufacturer its service agent or suitably...

Страница 5: ...hing on off FR1 speed controller W1 power cord with mains plug Exhaust spigot diameter mm Motor type C electronically commutated motor Fan series The product described herein is a centrifugal inline f...

Страница 6: ...al TECHNICAL DATA ErP 2018 local demand control TECHNICAL DATA Centro M EC 100 Centro M EC 125 Centro M EC 150 Centro M EC 160 Centro M EC 200 Centro M EC 200 max Centro M EC 250 L Centro M EC 250 Cen...

Страница 7: ...65 360 320 220 25 25 30 Centro M EC 200 198 345 6 435 395 355 245 25 30 40 Centro M EC 200 max 198 345 6 435 395 355 255 25 30 40 Centro M EC 250 248 345 6 435 395 355 250 25 30 40 Centro M EC 250 L 2...

Страница 8: ...to 1 air duct diameter on intake side equal to 3 air duct diameters on outlet side If the air ducts are too short or not connected at any spigot protect the fan inner parts from ingress of foreign ob...

Страница 9: ...9 INSTALLATION STEPS Disconnect the fan from power supply Install the fixing brackets Lean the fan against the installation place and mark the fastening holes Drill the holes and insert the expansion...

Страница 10: ...ing on the wire type maximum permissible heating temperature insulation length and installation method Connect the fan to power mains via an external automatic circuit breaker installed at the power i...

Страница 11: ...ations are rare The TSI lights up and the fan switches to the maximum speed as the room air temperature exceeds the set point As the air temperature drops 2 C below the set point or if the initial tem...

Страница 12: ...l between the cleaning to perform the cleaning first remove the screws and the fan cover Wipe the impeller blades with a cloth wetted in a mild detergent solution Avoid water dripping on the electric...

Страница 13: ...ble hoist machinery for handling and storage operations to prevent possible damage to the unit Follow the handling requirements applicable for the particular type of cargo The unit can be carried in t...

Страница 14: ...the Seller for warranty service The manufacturer s warranty does not apply to the following cases User s failure to submit the unit with the entire delivery package as stated in the user s manual incl...

Страница 15: ...TIFICATE The unit _____________________________________ is installed pursuant to the requirements stated in the present user s manual Installation Stamp Company name Address Phone Number Installation...

Страница 16: ...www blaubergventilatoren de B88EN 06...

Отзывы: