www.blaubergventilatoren.de
Ceileio
10
CONNECTION TO POWER MAINS
The fan is rated for connection to single-phase AC 220-240 V/ 50/ (60) Hz power supply.
The fan must be connected to power mains using durable, insulated and heat-resistant conductors (cables and wires) via the circuit
breaker QF integrated into the house cabling system.
The external circuit breaker installation place must ensure unhampered access for emergency shutdown of the unit.
WIRING DIAGRAMS
ACCESS TO THE TERMINAL BOX FOR WIRING THE FAN
L2
L1
N
L
N
LT
N
L
N
L
1
2
3
4
5
6
7
LIGHT
(contact socket is available only for
the models with LED light)
FAN
Х1
QF
QF
120 V
60 Hz
120 V
60 Hz
Remove the decorative grille.
For accessing the connection terminals
loosen the screw on the terminal box
lid and take the lid off.
Remove the protective cap and install the cable gland.
ANY TAMPERING WITH THE INTERNAL CONNECTIONS IS PROHIBITED
AND WILL VOID THE WARRANTY.
DISCONNECT THE UNIT FROM POWER MAINS PRIOR TO ANY OPERATIONS.
THE UNIT MUST BE CONNECTED TO POWER MAINS BY A QUALIFIED ELECTRICIAN.
THE RATED ELECTRICAL PARAMETERS OF THE UNIT ARE SHOWN
ON THE RATING PLATE.