LAMP REPLACEMENT 

DISCONNECT THE UNIT FROM POWER SUPPLY BEFORE 

ANY MAINTENANCE OPERATIONS!

1. Remove the decorative grille: 

•  Pull the grille to release the springs from the holders on the casing. 
•  Take out the lamp power socket from the respective socket on the casing.
•  Take out the power socket of the sensors from the respective sockets on the control unit (applicable for TH and TP models).

2. Take off the surface-mounted luminaire.

Press the holders on the reverse side of the grille frame and take off the surface-mounted luminaire.

3. Replace the lamps. 
4. Reassemble the unit in the reverse order. 

TROUBLES AND TROUBLESHOOTING 

TROUBLE 

POSSIBLE REASONS 

TROUBLESHOOTING

The fan does not get started. 

No power supply.

Check the electric connections and the operation status of the 
circuit breaker. 

Motor jam.

Turn the fan off. Troubleshoot clogging of the impeller. Restart 
the fan. 

Automatic circuit breaker tripping 
during the unit turning on.  

Over current as a result of short circuit 
in the electric circuit leads to tripping of 
the circuit breaker. 

Disconnect the fan from power supply and contact the product 
Seller. Do not turn the fan on again! 

Low air flow. 

Air ducts or other components of the 
ventilation system are clogged. The 
impeller is clogged. The air ducts are 
damaged. The air dampers are closed.

Clean the air ducts, the impeller and other components of 
the ventilation system. Make sure that the air ducts are not 
damaged. Make sure that the air dampers and louvre shutters 
are open. 

Содержание Ceileo 200

Страница 1: ...Ceileo 200 250 300 Ceileo 200 250 300 H IR Ceileo 200 250 300 Light Ceileo 200 250 300 Light H IR CENTRIFUGAL CEILING EXTRACT FAN USER S MANUAL EN...

Страница 2: ...y prior to installing and operating the unit All user s manual requirements as well as the provisions of all the applicable local and national construction electrical and technical norms and standards...

Страница 3: ...the electric parts of the unit against ingress of water Do not allow children to operate the unit Disconnect the unit from power mains prior to any technical maintenance Do not store any explosive or...

Страница 4: ...REDUCED PHYSICAL MENTAL OR SENSORY CAPACITIES OR THOSE WITHOUT THE APPROPRIATE TRAINING THE UNIT MUST BE INSTALLED AND CONNECTED ONLY BY PROPERLY QUALIFIED PERSONNEL AFTER THE APPROPRIATE BRIEFING THE...

Страница 5: ...SIONS OF THE FANS Ceileo 300 Ceileo 300 T H IR A E H d D L2 L1 B C A E H B L1 L2 d D h C b a A E C B D H h L1 A E C h B H L1 D b a Ceileo 200 250 Light Ceileo 200 250 Light T H IR Ceileo 300 Light Cei...

Страница 6: ...2 0 17 0 28 Max airflow m3 h 130 210 130 225 170 260 160 270 220 300 200 320 Max airflow l s 36 58 36 63 47 72 44 75 61 83 56 89 SFP W l s 0 55 0 50 0 58 0 54 0 49 0 54 0 56 0 67 0 51 0 59 0 63 0 71 W...

Страница 7: ...etected more the fan keeps running for a set turn off delay time adjustable from 1 to 90 minutes and the reverts to the initial operation status Humidity sensor H If the indoor humidity exceeds the se...

Страница 8: ...e H models with a humidity sensor remove the protective cap from the grille prior to its installation Route the contact socket of the sensor H or IR via the opening in the grille and connect the senso...

Страница 9: ...tion to one of the ceiling joists Installation between the ceiling joists Fixation between the ceiling joists using the mounting brackets Additional fastening holes in the fan casing may be used for m...

Страница 10: ...CESS TO THE TERMINAL BOX FOR WIRING THE FAN L2 L1 N L N LT N L N L 1 2 3 4 5 6 7 LIGHT contact socket is available only for the models with LED light FAN 1 QF QF 120 V 60 Hz 120 V 60 Hz Remove the dec...

Страница 11: ...the fan starts operating in set mode Once the button is pressed the indicator displays the turn off delay timer setting the first Setup menu entry Use or buttons to navigate in the Setup menu Press t...

Страница 12: ...n shutdown the fan keeps running for a set turn off delay time and then switches from the mode to the mode SETUP OF THE OPERATION MODES AND The and modes can take the following values for the fan with...

Страница 13: ...TROUBLE POSSIBLE REASONS TROUBLESHOOTING The fan does not get started No power supply Check the electric connections and the operation status of the circuit breaker Motor jam Turn the fan off Trouble...

Страница 14: ...e hoist machinery for handling and storage operations to prevent possible damage to the unit Follow the handling requirements applicable for the particular type of cargo The unit can be carried in the...

Страница 15: ...DOES NOT APPLY TO THE FOLLOWING CASES User s failure to submit the unit with the entire delivery package as stated in the user s manual including submission with missing component parts previously di...

Страница 16: ...e Ceileo _______________________ unit has been connected to power mains pursuant to the requirements stated in the present user s manual Installation Company Stamp SELLER ADDRESS PHONE NUMBER INSTALLA...

Страница 17: ...www blaubergventilatoren de Ceileio 17...

Страница 18: ...www blaubergventilatoren de Ceileio 18...

Страница 19: ...www blaubergventilatoren de Ceileio 19...

Страница 20: ...www blaubergventilatoren de B166 1EN 09...

Отзывы: