VENTILATOR CONTROL WITH THE BUTTONS ON THE INDOOR UNIT

The speed selection sequence is as follows: I-II-III-Standby. All the units integrated in a single network operate according to 

the speed settings of the Master unit.

I: permanent indicator glowing indicates operation of the unit at Speed I.

The indicator blinks when the first speed timer is activated.

I and II: permanent glowing of the indicators I and II indicates operation of the unit at Speed II.

I, II and III: permanent glowing of the indicators I, II and III indicates operation of the ventilator at Speed III. Blinking of the 

indicators I, II and III indicates activation of the timer for Party mode or the turn-off delay timer triggered by any connected 

external sensors or the integrated humidity sensor.

Regeneration mode

Vento Expert A50-1 Pro/Pro3

The rotation direction of the fan changes to opposite every 70 seconds. Heat recovery is performed in this mode.

Vento Expert Duo A30-1 Pro

The rotation direction of both fans changes to opposite every 70 seconds. Heat recovery is performed in this mode.

Ventilation mode

Vento Expert A50-1 Pro/Pro3

The ventilator operates in permanent supply or extract mode at a set speed. The air flow direction depends on positioning 

of the DIP switch (set to air extract by default).

Vento Expert Duo A30-1 Pro

One fan operates in the air extract mode and the other fan operates in the air supply mode at a set speed. The fans do not 

change their rotation direction.

Filter

Contamination indicator of filters.

 90 days (continuous operation) after installation of the cartridge the Filter contamination 

indicator starts glowing. In this case, clean or replace the filters (see the “Technical maintenance” section).

In case of in-series connection, the Master ventilator indicator has a steady glow and the indicator of the ventilator requiring 

filter replacement blinks.

To reset the filter timer, turn the DIP switch No. 8 on for not less than 3 seconds and then turn it off.

Alarm

Alarm indicator for emergency shutdown of the unit.

 Permanent glowing of the Alarm indicator of the Master unit 

indicates an alarm in the network of the connected ventilation units. Its blinking indicates shutdown of a specific ventilation 

unit in the network. 

In case of an emergency shutdown of a Vento Expert A50-1 Pro/Pro3 unit in the network the defective ventilation unit is 

marked with the blinking Alarm indicator. All the connected Vento Expert A50-1 Pro/Pro3 ventilation units are also stopped.
In case of an emergency shutdown of the Vento Expert Duo A30-1 Pro unit, the defective ventilation unit is marked with the 

blinking Alarm indicator. The defective ventilation unit shuts down and the other connected ventilation units continue their 

operation.

Master

Master unit indicator.

 Permanent glowing of the indicator shows the leading unit in the network (Master unit). Indicator 

blinking indicates the driven unit (Slave unit) and no connection to the Master unit.

No glowing of the lamp indicator means that this ventilation unit is a Slave ventilation unit and it is connected to a Master 

unit.

REMOTE CONTROL OF THE VENTILATION UNIT

Turning the ventilator on/off. The unit may be turned off only if it is enabled by the settings.

Reset of alarm and timer settings.

Ventilator speed selection: III-II-I speeds respectively.

Regeneration mode

Vento Expert A50-1 Pro/Pro3

The rotation direction of the fan changes to opposite every 70 seconds. Heat recovery is performed in this mode.

Vento Expert Duo A30-1 Pro

The rotation direction of both fans changes to opposite every 70 seconds. Heat recovery is performed in this mode.

Ventilation mode

Vento Expert A50-1 Pro/Pro3

The ventilator operates in permanent supply or extract mode at a set speed. The air flow direction depends on 

positioning of the DIP switch (set to air extract by default).

Vento Expert Duo A30-1 Pro

One fan operates in the air extract mode and the other fan operates in the air supply mode at a set speed. The fans 

do not change their rotation direction.
Timer buttons:

 

 Party mode: 4 hours at the Speed 

III

.                                        

 Night mode: 8 hours at the Speed 

I

Upon expiration of the set time period the ventilator reverts to a pre-set speed.

Press any button of the manual speed setting to deactivate the timer.

Содержание 4058448022999

Страница 1: ...Single room reversible energy recovery ventilator USER S MANUAL EN Vento Expert A50 1 Pro Vento Expert A50 1 Pro3 Vento Expert Duo A30 1 Pro ...

Страница 2: ...e Vento Expert Duo A50 30 1 Pro Pro3 unit and all its modifications Technical and maintenance staff must have theoretical and practical training in the field of ventilation systems and should be able to work in accordance with workplace safety rules as well as construction norms and standards applicable in the territory of the country The information in this user s manual is correct at the time of...

Страница 3: ... the entire service life of the unit While transferring the unit control the user s manual must be turned over to the receiving operator UNIT INSTALLATION AND OPERATION SAFETY PRECAUTIONS Disconnect the unit from power mains prior to any installation operations Unpack the unit with care The unit must be grounded While installing the unit follow the safety regulations specific to the use of electri...

Страница 4: ...stances in close proximity to the unit When the unit generates unusual sounds odour or emits smoke disconnect it from power supply and contact the Seller Do not open the unit during operation Do not direct the air flow produced by the unit towards open flame or ignition sources Do not block the air duct when the unit is switched on In case of continuous operation of the unit periodically check the...

Страница 5: ...rous materials coarse dust soot and oil particles or environments favourable for the formation of hazardous substances toxic substances dust pathogenic germs Name Vento Expert A50 1 Pro Pro3 Vento Expert Duo A30 1 Pro Indoor unit of the ventilator 1 pc 1 pc Air duct 1 pc 1 pc Air flow distributor 3 6 pcs Sound absorbing material 1 pc Assembled cartridge 1 pc 1 pc Outer ventilation hood 1 pc 1 pc R...

Страница 6: ...l are indicated on the unit casing The air duct length depends on the unit model refer to the Designation Key section page 6 The supplied ventilation hood model depends on the ventilator model The overall dimensions of the outer ventilation hood the required outside protrusion length of the air duct A and the mounting sequence of the hood are stated in its mounting instruction The overall dimensio...

Страница 7: ...tor Frontpartoftheindoorunitwithafrontpanel Fulfils the decorative function The design enables to shut off the air duct in case of an extended downtime of the ventilator The front part of the Vento Expert Duo unit is used for air filtration Back part of the indoor unit The unit includes a circuit control board and basic controls located on the side part Back part of the indoor unit The unit includ...

Страница 8: ...e of the ventilator fans operates in the air extract mode and the other one operates in the air supply mode at a set speed The fans do not change their rotation direction Boost if the sensor is actuated the ventilator follows one of two functioning algorithms set via the DIP switch during the ventilator setup For details see page 14 The DIP switch is set to OFF the ventilator runs in the extract m...

Страница 9: ...500 min 500 min 500 2 Install the air duct in the wall and fix it with mounting foam The air duct end must protrude for the distance that enables installation of the outer ventilation hood see the User s manual for the outer ventilation hood A min 3 mm Fill the gaps between the wall and the hole with a mounting foam Foam wedge Install the air duct in the wall in such a way so it protrudes from the...

Страница 10: ...the master plate 4 Unlatch and detach the front part of the indoor unit from its back part The thermal actuator rod must be in lower position when installing the front panel of the Vento Expert A50 1 Pro unit 5 Fix the back part of the indoor unit on the wall with the screws supplied with the mounting kit of the ventilator Remove the two retaining screws from the left transparent cover to enable a...

Страница 11: ...from the outside Roll the layer of the sound absorbing material to match the air duct diameter The protecting paper layer must be outside Insert the sound absorbing roll into the cartridge against stop Make a mark at the end of the air duct remove the material and cut the roll as marked After that insert the ready roll into the air duct 9 Install the sectional air flow separators from the outside ...

Страница 12: ... only The actual conductor cross section selection must be based on its type maximum permissible heating insulation length and installation method Use copper wires for all the electric connections Connect the ventilator to power mains in compliance with the wiring diagram EXTERNAL CONNECTIONS DIAGRAM The ventilator design enables connecting external devices with a normally open contact NO contact ...

Страница 13: ...Slave 1 Slave N N L N L In Gnd Gnd Out NO1 NO2 12V N L N L In Gnd Gnd Out NO1 NO2 12V N L N L In Gnd Gnd Out NO1 NO2 12V N L Power input АС 100 240V 50 60 Hz to the next ventilator to the next ventilator to the next ventilator VENTILATOR SET UP ON DIP 1 2 3 4 5 6 7 8 Open the rubber plug DIP switch under the plug Prior to operating the ventilator set it up using the DIP switch It is located on the...

Страница 14: ...er elapsing of the time set on the turn on delay timer Humidity control is disabled Set value 40 Set value 50 Set value 60 Set value 70 Set value 80 3 4 5 3 4 5 3 4 5 3 4 5 3 4 5 3 4 5 Delay timer During activation of the humidity sensor or any other external device the ventilator switches to higher speed After normalization of the indoor humidity level or any other air parameters the ventilator w...

Страница 15: ...or for emergency shutdown of the unit Permanent glowing of the Alarm indicator of the Master unit indicates an alarm in the network of the connected ventilation units Its blinking indicates shutdown of a specific ventilation unit in the network In case of an emergency shutdown of a Vento Expert A50 1 Pro Pro3 unit in the network the defective ventilation unit is marked with the blinking Alarm indi...

Страница 16: ...Vento Expert Duo A30 1 Pro Press the side tabs to detach the front part of the indoor unit from its back part and close the air duct Then gently unlatch and remove the front panel from the front part of the indoor unit Remove the air flow separator by pulling one of the side clamps Install the front part of the indoor unit into place Install the front panel on the front part of the indoor unit and...

Страница 17: ...l Remove the filters for cleaning Perform all the above operations in the reverse order after cleaning Vento Expert A50 1 Pro Pro3 1 Press the latches on the side of the indoor control unit to take off the front part Please make sure the louver actuator rod is in lower position during re installation of the front panel If the thermal actuator rod is up please wait for about 2 minutes until it goes...

Страница 18: ...ery clean the regenerator with a vacuum cleaner at least once a year To reset the filter timer connect the ventilator to the power supply using the circuit breaker before installing the front panel of the indoor unit into its place After that turn the DIP switch No 8 on for not less than 3 seconds and then turn it off For details see page 14 If necessary the remote control battery may be replaced ...

Страница 19: ... after transportation at low temperatures allow the unit to warm up at operating temperature for at least 3 4 hours TROUBLESHOOTING POSSIBLE REASONS ANDTROUBLESHOOTING Problem Possible reasons Troubleshooting When switching on the ventilator the fan does not start No power supply Make sure the power supply line is connected correctly otherwise troubleshoot the connection error The motor is jammed ...

Страница 20: ...ual Contact the Seller for warranty service The manufacturer s warranty does not apply to the following cases User s failure to submit the unit with the entire delivery package as stated in the user s manual including submission with missing component parts previously dismounted by the user Mismatch of the unit model and the brand name with the information stated on the unit packaging and in the u...

Страница 21: ...www blaubergventilatoren de Vento Expert Duo A50 30 1 Pro Pro3 21 ...

Страница 22: ...www blaubergventilatoren de Vento Expert Duo A50 30 1 Pro Pro3 22 ...

Страница 23: ... INSTALLATION CERTIFICATE The Vento Expert ________________ unit is installed pursuant to the requirements stated in the present user s manual Installation Stamp Company name Address Phone Number Installation Technician s Full Name Installation Date Signature The unit has been installed in accordance with the provisions of all the applicable local and national construction electrical and technical...

Страница 24: ...www blaubergventilatoren de B139EN 05 ...

Отзывы: