DELIVERY SET

Fan 

 

    — 

pc.

Screws and dowels   

 

 

 

— 4 pcs.

Plastic screwdriver (for models with a timer)              

— 1 pc.

User’s 

manual 

 

    — 

pc.

Packing 

box 

 

    — 

pc.

BRIEF DESCRIPTION

The product described herein is a mixed-flow inline fan for supply or extract ventilation of premises.
The fan is designed for connection to ø 100, 125, 150, 160, 200, 250 and 315 mm air ducts.
The unit is equipped with a two speed motor.

Ø D

B

H

L

Turbo 100

97

195,8

241/255*

302,5

Turbo 125

123

195,6

241/255*

258,5

Turbo 150

148

220,1

251/265*

289

Turbo 160

158

220,1

251/265*

289

Turbo 200

199

239

261/278*

295,5

Turbo 250

247

287

323/340*

383

Turbo 315

310

362

408/424*

445

       

* Turbo GI1/G1/GTI1/GT1/GSI1/GS1/FR1

Содержание 4058448018060

Страница 1: ...USER S MANUAL Turbo INLINE MIXED FLOW FANS EN ...

Страница 2: ...ntenance staff must have theoretical and practical training in the field of ventilation systems and should be able to work in accordance with workplace safety rules as well as construction norms and standards applicable in the territory of the country CONTENTS Delivery set 7 Brief description 7 Operation guidelines 8 Designation key 9 Mounting 10 Control logic 11 Technical maintenance 13 Troublesh...

Страница 3: ...s with a work permit for electrical units up to 1000V are allowed for installation The present user s manual should be carefully read before beginning works Check the unit for any visible damage of the impeller the casing and the grille before starting installation The casing internals must be free of any foreign objects that can damage the impeller blades While mounting the unit avoid compression...

Страница 4: ...close or block the intake or extract vents in order to ensure the efficient air flow Do not sit on the unit and do not put objects on it The information in this user s manual was correct at the time of the document s preparation The Company reserves the right to modify the technical characteristics design or configuration of its products at any time in order to incorporate the latest technological...

Страница 5: ...must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a safety hazard This appliance can be used by children aged from 8 years and above and persons with reduced physical sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand ...

Страница 6: ...that is regularly switched on and off by the utility Ensure that the unit is switched off from the supply mains before removing the guard The appliance may adversely affect the safe operation of appliances burning gas or other fuels including those in other rooms due to back flow of combustion gases These gases can potentially result in carbon monoxide poisoning After installation of the unit the ...

Страница 7: ...xtract ventilation of premises The fan is designed for connection to ø 100 125 150 160 200 250 and 315 mm air ducts The unit is equipped with a two speed motor Ø D B H L Turbo 100 97 195 8 241 255 302 5 Turbo 125 123 195 6 241 255 258 5 Turbo 150 148 220 1 251 265 289 Turbo 160 158 220 1 251 265 289 Turbo 200 199 239 261 278 295 5 Turbo 250 247 287 323 340 383 Turbo 315 310 362 408 424 445 Turbo G...

Страница 8: ...tion in the system Ingress protection rating against access to hazardous parts and water ingress is IPX4 The unit is rated as a Class II electrical appliance The fan is rated for operation at the ambient air temperature from 1 C up to 40 C Power supply V Hz Transported air temperature C 220 240 50 25 60 220 60 25 40 To comply with the ErP 2018 regulation a local demand controller and speed control...

Страница 9: ...controller with an electronic thermostat and an integrated temperature sensor Timer based operation logic GT1 speed controller with an electronic thermostat and an outdoor temperature sensor fixed on a 4 m cord Timer based operation logic GSl1 speed controller with an electronic thermostat and an integrated temperature sensor Temperature based switching on off GS1 speed controller with an electron...

Страница 10: ... a hood in case of vertical fan mounting The outlet spigot must always be connected to the air duct The fan mounting sequence is shown in Fig 3 11 and 14 19 The fan wiring diagrams are shown in Fig 12 13 Some fan models are equipped with a plastic limit stop in front of the L1 terminal Remove the limit stop for connection to the L1 terminal Designation L1 minimum speed terminal L2 maximum speed te...

Страница 11: ...o XXX T fan starts running after the external switch supplies control signal to the LT input terminal for example during turning the light on After removal of the control signal the fan continues to run within the set time adjustable with the turn off delay timer from 2 to 30 minutes To adjust the fan turn off delay time rotate the control knob T clockwise to increase and counter clockwise to decr...

Страница 12: ...mperature or timer controls Turbo Gl1 G1 the fan switches to the maximum speed as the room air temperature exceeds the set point As the air temperature drops down 2 C below the temperature set point or if the initial temperature is below the set point the fan operates with the set speed Turbo GTl1 GT1 the fan switches to the maximum speed as the room air temperature exceeds the set point As the ro...

Страница 13: ... Increased noise vibration The impeller is clogged Clean the impeller The fan is not secured well or is not mounted properly Troubleshoot the installation error The ventilation system is clogged Clean the ventilation system TECHNICAL MAINTENANCE The fan surfaces must be regularly cleaned once in 6 months from dirt and dust Fig 24 30 Disconnect the fan from power mains prior to any maintenance oper...

Страница 14: ...r handling and storage operations to prevent possible damage to the unit Follow the handling requirements applicable for the particular type of cargo The unit can be carried in the original packaging by any mode of transport provided proper protection against precipitation and mechanical damage The unit must be transported only in the working position Avoid sharp blows scratches or rough handling ...

Страница 15: ...itation any costs associated with installation reinstallation or transporting the product Additional Information Our goods come with guarantees that cannot be excluded under the Australian Consumer Law You are entitled to a replacement of the purchased product for a major failure of the product You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quali...

Страница 16: ... STIPULATED HEREIN WILL ENSURE A LONG AND TROUBLE FREE OPERATION OF THE UNIT USER S WARRANTY CLAIMS SHALL BE SUBJECT TO REVIEW ONLY UPON PRESENTATION OF THE UNIT THE PAYMENT DOCUMENT AND THE USER S MANUAL WITH THE PURCHASE DATE STAMP ...

Страница 17: ...17 EN min 1 m 1 2 ...

Страница 18: ...18 EN QF 3 4 5 6 ...

Страница 19: ...19 EN 7 8 9 10 11 ...

Страница 20: ...20 EN MAX MIN MAX MIN N L2 N L QF QF N L1 L2 S N L M N L1 N L QF M M L2 L1 N L M MAX 12 Turbo ...

Страница 21: ...IN MAX MIN L2 L1 N L X N L ST QF N L LT L1 X S N L ST QF N L LT L1 X L2 N L ST QF N L LT X N L ST QF N L LT L1 X S N L ST QF N L LT L1 X N L ST QF N L LT L2 X 13 Terminal block for 5 contacts Terminal block for 4 contacts Turbo T ...

Страница 22: ...22 EN 25 QF 14 15 16 17 18 19 ...

Страница 23: ...23 EN MIN MAX STOP 3030 min 2 min 20 21 ...

Страница 24: ...24 EN 33 22 23 Thermostat control knob Speed control knob Speed control knob Turbo Gl1 GTl1 GSl1 Turbo FR1 Turbo G1 GT1 GS1 ...

Страница 25: ...25 EN 24 25 26 27 ...

Страница 26: ...26 EN 18 28 29 30 ...

Страница 27: ...27 EN Quality Inspector s Stamp Manufacture Date Sold by name and stamp of the seller Purchase Date ...

Страница 28: ...Blauberg_Australasia_B77EN 05 www blaubergventilatoren de Turbo________________________ ...

Отзывы: